Search results for "electrical"
showing 10 items of 11048 documents
Effect of Er3+-doping on 65GeS2-25Ga2S3-10CsCl glass probed by annihilating positrons
2019
Abstract Effect of Er3+-doping resulting in pronounced mid-IR fluorescence functionality was examined first in chalcohalide 65GeS2-25Ga2S3-10CsCl glass using positron annihilation lifetime (PAL) spectroscopy. The detected PAL spectra were reconstructed from unconstrained x2-term analysis employing two-state simple trapping model for one kind of positron trapping free-volume defects, the parameterization being performed at the example of 65GeS2-25Ga2S3-10CsCl glass doped with 0.6 at. % of Er3+. The observed decrease in positron trapping rate was proved to be primary void-evolution process in this Er-activated glass, like in many other chalcogenide glasses affected by rare earth doping. The n…
Postmortem Electrical Conductivity Changes of Dicentrarchus labrax Skeletal Muscle: Root Mean Square (RMS) Parameter in Estimating Time since Death
2022
Electric impedance spectroscopy techniques have been widely employed to study basic biological processes, and recently explored to estimate postmortem interval (PMI). However, the most-relevant parameter to approximate PMI has not been recognized so far. This study investigated electrical conductivity changes in muscle of 18 sea bass specimens, maintained at different room temperatures (15.0 °C; 20.0 °C; 25.0 °C), during a 24 h postmortem period using an oscilloscope coupled with a signal generator, as innovative technology. The root mean square (RMS) was selected among all measured parameters, and recorded every 15 min for 24 h after death. The RMS(t) time series for each anima…
Partial Discharges in HVDC Cables - The Effect of the Temperature Gradient During Load Transients
2021
The paper investigates the role of the space charge accumulation phenomena in the inception of Partial Discharges (PD) in a defect within the bulk of the dielectrics of a High Voltage Direct Current (HVDC) cable. It is widespread accepted that the number of PD occurring in an HVDC cable during its lifetime is largely less than that under AC voltage stress. This is essentially due to higher values of the voltage between the conductor and the screen needed to trigger PD under a steady DC voltage than the same value under AC stress. Nevertheless, due to the dependency of the electrical conductivity of the insulation on the electric field and temperature, PD in HVDC cables is strongly influence…
A Power Law Behavior in the Incentivized Italian Photovoltaic Market
2018
The Italian photovoltaic (PV) marketis analyzed by using the data contained in the database that describes all PV Plants installed in Italy under the incentive program called “2nd Conto Energia”. It is shown that the cumulative probability distribution of the size of the installed PV plants has a broken power tail. An approach to partially quantify the effect of the economic, juridical and technical rules is introduced in order to show how the regulatory body influences the power tail of the cumulative probability curve.
An Innovative Coupling Solution for Power Line Communication in MV Electrical Networks
2019
One of the main problems in the diffusion of power line communication (PLC) in medium voltage (MV) networks is the need of a dedicated PLC coupler to be installed all over the network. To avoid this problem, the authors have studied, prototyped and patented an innovative PLC coupling solution which uses electrical elements embedded in most of the switchgears already installed in MV networks, i.e. the capacitive dividers of the voltage detecting systems (VDS). The new solution prototype is described in this paper, highlighting the advantages in terms of a significant reduction of both direct costs of equipment and infrastructures and indirect costs of installation and service interruption. T…
Model of line to shield power line communication system on a Medium Voltage network
2010
In this paper a complete model of a power line communication (PLC) system on a Medium Voltage (MV) network is presented in the case of a line-ground configuration. A simple and friendly Simulink (R) software is used to develop the model. A distributed parameter MV cable model in line-ground configuration is considered together with the power transformers, the signal coupling networks and the receiving and transmitting line coupling interface of a ST7540 FSK powerline transceiver. The performances of the complete PLC communication system are evaluated for different line lengths by means of the attenuation computed as ratio between the received and transmitted voltage signals.
Power Line Communication in Medium Voltage Systems: Characterization of MV Cables
2008
The aim of this paper is to illustrate the development of a theoretical and experimental study on the characterization of medium voltage (MV) cables in the frequency range 25-200 kHz. Two transmission line configurations, line-ground and line-line, were considered in order to evaluate the main parameters, such as the characteristic impedance and the attenuation constant alpha. A simplified model of the line-ground configuration is proposed which allows one to evaluate the characteristic impedance and the attenuation constant by means of geometrical dimensions. The model was verified by experimental measurements on commonly used MV cables, RG7H1R, with an aluminium core of different sections…
Simulation of a Power Line Communication System in Medium and Low Voltage Distribution Networks
2011
The aim of the paper is to study the influence of the power transformer on signal transmission in the case of a power line communication (PLC) system in a overhead Medium Voltage (MV) power network. A model of the PLC system was carried out by means of the Simulink® software. A distributed parameter MV overhead line, two power transformers, the signal coupling networks and the receiving and transmitting line coupling interface of a ST7540 FSK powerline transceiver were included in the model. The performances of the complete PLC communication system are evaluated for different line lengths by means of the attenuation computed as ratio between the received and transmitted voltage signals.
A Line Impedance Calculator Based on a G3 PLC Modem Platform
2022
Power line communication (PLC) is one of the most today used technologies for both automatic meter reading and many other smart grid applications. In this framework, a characterization of the electrical network in the PLC frequency range is needed in terms of impedance measurement and received signal level. This can allow choosing the most suitable and less noisy frequency ranges for PLC transmission. Usually, these characterization measurements are performed with dedicated instrumentation and in the absence of mains voltage. This article wants to propose an alternative solution, which allows these kinds of measurements to be performed using electronic boards currently used as on-field appl…
THE ADMINISTRATIVE JUSTICE IN SPAIN: CURRENT SITUATION AND CHALLENGES
2016
Since the Spanish Constitution of 1978 there has been a full and effective administrative justice. The citizens have the possibility to request a judicial review of decisions taken by the public Administrations, while being either the owners of a subjective right or of a legitimate interest. The interim judicial protection is not limited to the suppression of the act or general provision and the Courts are invested with direct powers to enforce their sentences. However, different problematic issues about the inactivity of the public Administrations and the enforcement of sentences are the new challenges to ensure the administrative justice. To this it must be added that there are problems r…