Search results for "electromagnetic"

showing 10 items of 1595 documents

Tube Housing Leakiness Radiation and Patient Related Radiation Protective Measures – Gonads Radiation Exposure from Panoramic Radiography

2009

The purpose of this study was to compare patient- and apparatus related radiation protective measures considering gonad radiation exposure at panoramic radiography. The local dose (yGv) in the region of the gonads of a male Alderson-Rando-Phantom was measured by the dosimeter Tol-F (Berthold Technology, Germany) during panoramic radiography (PR) by the digital Orthophos XG plus®(Sirona / Bensheim, Germany). Different radiation protective measures was investigated during constant exposure parameters. In the second part of the survey the same ionisation chamber recorded the scattered radiation at the gonads level of the none protected phantom at various case shielding. Without protection apro…

medicine.medical_specialtyDosimeterbusiness.industryEquivalent doseRadiographyCollimatorRadiationlaw.inventionlawfashionfashion.garmentElectromagnetic shieldingmedicineLead apronRadiologyRadiation protectionbusinessNuclear medicine
researchProduct

Water detection in skin by dual-band photodiodes

2013

Purpose of this study was to develop a simple model for possibilities to detect water in skin by diffuse reflectance spectra. The model is based on comparison of diffuse reflectance spectra when illuminating water sample with LEDs of different wavelengths (1200 nm, and 1450 nm). The illumination LEDs were chosen due to water absorption differences in near-infrared spectral range. For detection, dual-band photodiode DSD2 by Thorlabs was used. Due to differences of water absorption at different wavelengths in the near-infrared spectral region, this correlation could be used for mapping of water content in skin or, in other words, determine relative moisture level in skin. Simple experimental …

medicine.medical_specialtyMaterials scienceDiffuse reflectance infrared fourier transformbusiness.industryNear-infrared spectroscopySignallaw.inventionSpectral imagingPhotodiodeOpticslawmedicineOptoelectronicsOscilloscopebusinessAbsorption (electromagnetic radiation)Light-emitting diodeSPIE Proceedings
researchProduct

Radiation transmission data for radionuclides and materials relevant to brachytherapy facility shielding

2008

To address the limited availability of radiation shielding data for brachytherapy as well as some disparity in existing data, Monte Carlo simulation was used to generate radiation transmission data for 60Co, 137CS, 198Au, 192Ir 169Yb, 170Tm, 131Cs, 125I, and 103pd photons through concrete, stainless steel, lead, as well as lead glass and baryte concrete. Results accounting for the oblique incidence of radiation to the barrier, spectral variation with barrier thickness, and broad beam conditions in a realistic geometry are compared to corresponding data in the literature in terms of the half value layer (HVL) and tenth value layer (TVL) indices. It is also shown that radiation shielding calc…

medicine.medical_specialtyMaterials sciencePhotonbusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineRadiationComputational physicsElectromagnetic shieldingmedicineMedical physicsRadiation protectionbusinessHalf-value layerBeam (structure)Medical Physics
researchProduct

Determination of chromophore distribution in skin by spectral imaging

2012

Possibilities to determine chromophore distribution in skin by spectral imaging were explored. Simple RGB sensor devices were used for image acquisition. Totally 200 images of 40 different bruises of 20 people were obtained in order to map chromophores bilirubin and haemoglobin. Possibilities to detect water in vitro and in vivo were estimated by using silicon photodetectors and narrow band LEDs. The results show that it is possible to obtain bilirubin and haemoglobin distribution maps and observe changes of chromophore parameter values over time by using a simple RGB imaging device. Water in vitro was detected by using differences in absorption at 450 nm and 950 nm, and 650 nm and 950 nm.

medicine.medical_specialtyMaterials sciencebusiness.industryPhotodetectorChromophorelaw.inventionSpectral imagingImaging spectroscopyOpticslawmedicineOptoelectronicsRGB color modelDiffuse reflectionbusinessAbsorption (electromagnetic radiation)Light-emitting diodeSPIE Proceedings
researchProduct

Study and modulation of human cortical excitability with transcranial magnetic stimulation.

1998

Transcranial magnetic stimulation (TMS) can be applied in different paradigms to obtain a measure of various aspects of cortical excitability. These different TMS paradigms provide information about different neurotransmitter systems, enhance our understanding about the pathophysiology of neuropsychiatric conditions, and in the future may be helpful as a guide for pharmacological interventions. In addition, repetitive TMS (rTMS) modulates cortical excitability beyond the duration of the rTMS trains themselves. Depending on rTMS parameters, a lasting inhibition or facilitation of cortical excitability can be induced. These effects can be demonstrated neurophysiologically or by combining rTMS…

medicine.medical_specialtyNeurologyPhysiologyNerve netmedicine.medical_treatmentNeural ConductionNeural Inhibitionbehavioral disciplines and activitiesSynaptic TransmissionElectromagnetic FieldsNeuroimagingPhysiology (medical)Physical Stimulationmental disordersNeural PathwaysmedicineHumansEvoked PotentialsNeurorehabilitationCerebral CortexDepressive DisorderMovement Disordersbusiness.industrymusculoskeletal neural and ocular physiologyNeural InhibitionTranscranial magnetic stimulationmedicine.anatomical_structurenervous systemNeurologyCerebral cortexNeurology (clinical)Nerve NetbusinessNeurosciencepsychological phenomena and processesPhysical StimulationJournal of clinical neurophysiology : official publication of the American Electroencephalographic Society
researchProduct

Broad beam transmission data for the shielding of brachytherapy facilities

2008

medicine.medical_specialtyOpticsOncologybusiness.industrymedicine.medical_treatmentElectromagnetic shieldingBrachytherapymedicineRadiology Nuclear Medicine and imagingMedical physicsBeam transmissionbusinessBrachytherapy
researchProduct

Is MRI imaging in pediatric age totally safe? A critical reprisal.

2017

Current radiological literature is strongly focussed on radiation imaging risks. Indeed, given there is a small but actual augment in cancer risk from exposure to ionizing radiation in children, it is important to understand what the risk of alternative techniques could be. We retrospectively review literature data concerning possible MR imaging risks, focussing on the biological effects of MR, sedation and gadolinium compound risks when dealing with infant patients. The main concerns can be summarized in: (1) Biological effects of non-ionizing electromagnetic fields (EMF) employed—whose mechanisms of interaction with human tissues are polarization, induced current, and thermal heating, res…

medicine.medical_specialtySedationContrast MediaRisk Assessment030218 nuclear medicine & medical imaging03 medical and health sciencesPatient safety0302 clinical medicineElectromagnetic FieldsRisk FactorsMedicineHumansRadiology Nuclear Medicine and imagingGeneral anaesthesiaNeuroradiologyPaediatric populationmedicine.diagnostic_testbusiness.industryRisk FactorInfant NewbornInfantMagnetic resonance imagingInterventional radiologyGeneral MedicineMRForeign BodiesForeign BodieMagnetic Resonance ImagingElectromagnetic FieldRadiological weaponRadiologyPatient SafetySafetymedicine.symptombusinessRisk assessmentNoise030217 neurology & neurosurgeryHumanLa Radiologia medica
researchProduct

A Monte Carlo-aided design of a modular 241Am-Be neutron irradiator

2013

Monte Carlo studies aimed at designing a modular 241Am-Be neutron irradiator for testing neutron detectors and personal dosimeters and processing large volume samples are reported in this study. The evaluation of the shapes and thicknesses of the moderator and shielding materials was carried out by a MCNP5 Monte Carlo simulation code. The reliability of the simulation was experimentally verified by the activation of gold foils and TLD dosimeter measurements in an irradiation cell placed at the center of the test configuration.

medicine.medical_specialtySettore ING-IND/20 - Misure E Strumentazione NucleariPhysics::Instrumentation and DetectorsNuclear engineeringMonte Carlo methodPhysics::Medical PhysicsReliability (semiconductor)medicineNeutron detectionNeutronMedical physicslcsh:Nuclear and particle physics. Atomic energy. RadioactivitySafety Risk Reliability and Quality241Am-Be sourcePhysicsDosimeterbusiness.industryModular designMonte Carlo methodNuclear Energy and Engineeringneutron irradiator 241Am-Be source Monte Carlo methodElectromagnetic shieldingneutron irradiatorlcsh:QC770-798Thermoluminescent dosimeterbusinessNuclear Technology and Radiation Protection
researchProduct

Absorption of drugs from the bladder and intravesical chemotherapy

1976

medicine.medical_specialtybusiness.industryUrologyUrinary BladderUrologyAntineoplastic AgentsPharmaceutical PreparationsUrinary Bladder NeoplasmsInjections IntravenousAnimalsHumansMedicineRabbitsIntravesical chemotherapybusinessAbsorption (electromagnetic radiation)ThiotepaUrological Research
researchProduct

Assessment of the Short-Term Effects after High-Inductive Electromagnetic Stimulation of Pelvic Floor Muscles: A Randomized, Sham-Controlled Study

2020

Background: Physiotherapy should be performed by patients with stress or mixed urinary incontinence (SUI and MUI) to increase the strength and endurance of the pelvic floor muscles (PFMs). A method that can positively affect the pelvic floor is stimulation with high-inductive electromagnetic stimulation (HIES). The aim of the study was to evaluate the PFMs after the application of HIES in women with SUI and MUI by using surface electromyography (sEMG). Methods: This was a prospective, randomized, single-blind study with a sham intervention group. The participants were randomly assigned to the HIES group or sham group. The outcomes were features of the bioelectrical PFM activity assessed usi…

medicine.medical_specialtylcsh:MedicineUrinary incontinenceElectromyographyPelvic Floor MuscleArticle03 medical and health sciences0302 clinical medicineelectromagnetic fieldmedicine030212 general & internal medicineMixed urinary incontinence030219 obstetrics & reproductive medicinePelvic floorurinary incontinencemedicine.diagnostic_testbusiness.industrylcsh:RSignificant differenceSham InterventionGeneral MedicineElectromagnetic stimulationmedicine.anatomical_structurePhysical therapymedicine.symptombusinesspelvic floor muscleJournal of Clinical Medicine
researchProduct