Search results for "electron capture"
showing 10 items of 90 documents
Optimization of a matrix solid-phase dispersion method for the analysis of pesticide residues in vegetables
1996
A multiresidue method based on matrix solid-phase dispersion (MSPD) is studied to determine chlorfenvinfos, chlorpyrifos, fenarimol, iprodione, procimydone, propiconazole, tetradifon, triadimefon and vinclozolin in artichokes, green beans, lettuces and tomatoes. Alumina, silica and Florisil were assessed as extracting phases, and the extracts from Florisil were the cleanest. To facilitate manual extraction, sand was added to the sample together with the dispersing phase. Three eluting systems were then studied, and dichloromethane proved to be the best. Further purification can be performed using solid-phase cleanup after diluting extracts with aqueous solutions. Octyl- and octadecyl-silica…
Electron trapping centres and cross sections in LiNbO3studied by57Co Mössbauer emission spectroscopy
1999
Fast electron trapping processes and aliovalent charge states following the 57Co(EC)57Fe decay are studied in undoped, 5.4 mol% Mg-doped and 0.1 mol% Fe-doped LiNbO3 in various thermochemical reduction (TCR) states. Static 57Co Mossbauer emission spectra of congruent Mg:LiNbO3 recorded at T = 4.2 K in external magnetic field of 4.6 T are presented. Trapping cross section ratios are derived for Fe3+Li, Nb5+Li and Mg2+Li. A method to determine trap concentrations for TCR states of LiNbO3 is outlined. The electron-capture distance of the traps is found to be 2.7±1.4 nm. As this is much smaller than the 6 keV Auger-electron penetration depth, it is concluded that the distribution of the alioval…
Quantitative analysis of vitamin K1 and vitamin K1 2,3-epoxide in plasma by electron-capture gas-liquid chromatography.
1979
Improved method for quantitative analysis of vitamin K1i and vitamin K1 2,3-epoxide in human plasma by electron-capture gas-liquid capillary chromato…
1984
Reactive and organic halogen species in three different European coastal environments
2005
We present results of three field campaigns using active longpath DOAS (Differential Optical Absorption Spectroscopy) for the study of reactive halogen species (RHS) BrO, IO, OIO and I2. Two recent field campaigns took place in Spring 2002 in Dagebüll at the German North Sea Coast and in Spring 2003 in Lilia at the French Atlantic Coast of Brittany. In addition, data from a campaign in Mace Head, Ireland in 1998 was partly re-evaluated. During the recent field campaigns volatile halogenated organic compounds (VHOCs) were determined by a capillary gas chromatograph coupled with an electron capture detector and an inductively coupled plasma mass spectrometer (GC/ECD-ICPMS) in air and wat…
Comparative assessment of solid-phase extraction clean-up procedures, GC columns and perfluoroacylation reagents for determination of type B trichoth…
2005
Abstract Various solid-phase extraction (SPE) procedures for clean-up, two perfluoroacylation reagents (pentafluoropropionic anhydride (PFPA) and heptafluorobutyric anhydride (HFBA)) and two chromatographic columns (HP-1701 and HP-5) have been assessed comparatively to achieve the determination of type B trichothecenes (deoxynivalenol (DON), nivalenol (NIV), 3- and 15-acetyldeoxynivalenol (3- and 15-ADON)) in wheat grain by gas chromatography (GC)–electron-capture detection (ECD). Spiked wheat samples were extracted with acetonitrile–water (84:16, v/v). Tested SPE procedures were MycoSep 225 column, Florisil and different cartridges prepared in the laboratory with mixtures of various sorben…
Biogenic volatile organoiodine and organobromine hydrocarbons in the Atlantic Ocean from 42°N to 72°S
1997
During the cruise ANT X/1 and 2 of the research vessel Polarstern from November 1991 to March 1992, 39 surface water samples of the Atlantic Ocean from 42°N to 72.5°S were collected and analysed for their concentration of volatile iodinated and brominated hydrocarbons. The concentration of chlorophyll-a was used as an indicator for phytoplankton, which is one of the main producers of iodinated and brominated compounds in the ocean. For determination of chlorophyll-a, fluorescence spectroscopy was applied, whereas the measurement of halogenated volatile hydrocarbons was carried out by a purge and trap system with subsequent gas chromatographic separation and detection by an electron capture …
High-precision measurement of the mass difference between 102Pd and 102Ru
2019
The Q-value for the neutrinoless double electron capture on 102Pd, Qϵϵ(102Pd), is determined as the atomic mass difference between 102Pd and 102Ru. A precise measurement of the Qϵϵ(102Pd) at the SHIPTRAP Penning trap showed a more than 10σ deviation to the adopted Atomic Mass Evaluation (AME) value. The reliability of the SHIPTRAP measurement was challenged because the AME value was based on numerous experiments including β and electron capture decays and very precise (n, γ) data, all agreeing with each other. To solve the discrepancy, the Qϵϵ(102Pd) has now been determined with the JYFLTRAP Penning trap at the IGISOL facility in the Accelerator Laboratory of the University of Jyväskylä. Th…
High-precision measurement of the mass difference between 102Pd and 102Ru
2019
Abstract The Q-value for the neutrinoless double electron capture on 102Pd, Qϵϵ(102Pd), is determined as the atomic mass difference between 102Pd and 102Ru. A precise measurement of the Qϵϵ(102Pd) at the SHIPTRAP Penning trap showed a more than 10σ deviation to the adopted Atomic Mass Evaluation (AME) value. The reliability of the SHIPTRAP measurement was challenged because the AME value was based on numerous experiments including β and electron capture decays and very precise (n, γ) data, all agreeing with each other. To solve the discrepancy, the Qϵϵ(102Pd) has now been determined with the JYFLTRAP Penning trap at the IGISOL facility in the Accelerator Laboratory of the University of Jyva…
Excess electronic recoil events in XENON1T
2020
We report results from searches for new physics with low-energy electronic recoil data recorded with the XENON1T detector. With an exposure of 0.65 t-y and an unprecedentedly low background rate of $76\pm2$ events/(t y keV) between 1 and 30 keV, the data enables sensitive searches for solar axions, an enhanced neutrino magnetic moment, and bosonic dark matter. An excess over known backgrounds is observed at low energies and most prominent between 2 and 3 keV. The solar axion model has a 3.4$\sigma$ significance, and a 3D 90% confidence surface is reported for axion couplings to electrons, photons, and nucleons. This surface is inscribed in the cuboid defined by $g_{ae}<3.8 \times 10^{-12}$,…