Effect of double frequency heating on the lead afterglow beam currents of an electron cyclotron resonance ion source
2017
International audience; The effect of double frequency heating on the performance of the CERN GTS-LHC 14.5 GHz ElectronCyclotron Resonance (ECR) ion source in afterglow mode is reported. The source of the secondary microwave frequency was operated both in pulsed and continuous wave (CW) modes within the range of 12–18 GHz. The results demonstrate that the addition of the secondary frequency can significantly impact the extracted beam currents and the temporal stability of the beam during the afterglow discharge. For example, up to a factor of 2.6 increase was achieved for 208Pb35+ and a factor of 3.1 for 208Pb37+ compared to single frequency afterglow currents. It is shown that these effect…
Diagnostics of a charge breeder electron cyclotron resonance ion source helium plasma with the injection ofNa231+ions
2016
This work describes the utilization of an injected 23Na1+ ion beam as a diagnostics of the helium plasma of a charge breeder electron cyclotron resonance ion source. The obtained data allows estimating the upper limit for the ion-ion collision mean-free path of the incident sodium ions, the lower limit of ion-ion collision frequencies for all charge states of the sodium ions and the lower limit of the helium plasma density. The ion-ion collision frequencies of high charge state ions are shown to be at least on the order of 1–10 MHz and the plasma density is estimated to be on the order of 1011 cm−3 or higher. The experimental results are compared to simulations of the 23Na1+ capture into t…
Cooling of the plasma chamber for the AECR-U type electron cyclotron resonance ion source ARTEMIS
2001
Abstract The temperature distribution inside the ECRIS plasma chamber has been studied using finite element analysis. The main goal of these studies was to find out the safest cooling design for the temperature sensitive permanent magnets. In ECR ion sources they are used to provide the hexapole field. Two different designs for the cooling of the magnets were investigated. The temperature distribution on the surface of the plasma electrode was also studied. With the aid of the cooling simulations the most efficient cooling for the new ECR ion source was found. As a result of which, safety and higher reliability of operation can be reached.
Technical challenges in the construction of the steady-state stellarator Wendelstein 7-X
2013
The next step in the Wendelstein stellarator line is the large superconducting device Wendelstein 7-X, currently under construction in Greifswald, Germany. Steady-state operation is an intrinsic feature of stellarators, and one key element of the Wendelstein 7-X mission is to demonstrate steady-state operation under plasma conditions relevant for a fusion power plant. Steady-state operation of a fusion device, on the one hand, requires the implementation of special technologies, giving rise to technical challenges during the design, fabrication and assembly of such a device. On the other hand, also the physics development of steady-state operation at high plasma performance poses a challeng…
Ion source and low energy beam transport prototyping for a single-ended heavy ion ToF-ERDA facility
2023
We present the status of the ion source and low energy beam transport prototyping activities for a heavy ion time-of-flight elastic recoil detection analysis (ToF-ERDA) equipment, designed to accelerate a flux of 1–10 particle nano-Ampere of 40Ar6-12+ ions to 3–6 MeV energy for depth profiling of light elements. The prototype injector consists of a novel permanent magnet electron cyclotron resonance ion source CUBE-ECRIS with a minimum-B quadrupole field topology, and a 90° permanent magnet dipole with adjustable field strength for charge state selection. We report experimentally measured argon beam currents as a function of the applied microwave power and ion source potential to demonstrat…
Heavy ion and proton test site at JYFL-accelerator laboratory
1999
Abstract A radiation effects facility (RADEF) has been installed in the Accelerator Laboratory of the Department of Physics, University of Jyvaskyla (JYFL). The facility includes a special beam line dedicated to irradiation studies of semiconductor components and devices. It consists of a vacuum chamber including component movement apparatus and the necessary diagnostic equipment required for beam quality and intensity analysis. Construction of the station began in the summer of 1996, and in August 1997 the suitability of the station for space applications was evaluated. In this paper we introduce the accelerator laboratory along with the test station and its properties. We also describe th…
Dynamic regimes of cyclotron instability in the afterglow mode of minimum-Belectron cyclotron resonance ion source plasma
2016
The paper is concerned with the dynamic regimes of cyclotron instabilities in non-equilibrium plasma of a minimum-B electron cyclotron resonance ion source operated in pulsed mode. The instability appears in decaying ion source plasma shortly (1–10 ms) after switching off the microwave radiation of the klystron, and manifests itself in the form of powerful pulses of electromagnetic emission associated with precipitation of high-energy electrons along the magnetic field lines. Recently it was shown that this plasma instability causes perturbations of the extracted ion current, which limits the performance of the ion source and generates strong bursts of bremsstrahlung emission. In this artic…
Beam current oscillations driven by cyclotron instabilities in a minimum-Belectron cyclotron resonance ion source plasma
2014
Experimental observation of cyclotron instabilities in a minimum-B confined electron cyclotron resonance ion source plasma is reported. The instabilities are associated with strong microwave emission and a burst of energetic electrons escaping the plasma, and explain the periodic ms-scale oscillation of the extracted beam currents. Such non-linear effects are detrimental for the confinement of highly charged ions due to plasma perturbations at shorter periodic intervals in comparison with their production time. It is shown that the repetition rate of the periodic instabilities in oxygen plasmas increases with increasing magnetic field strength and microwave power and decreases with increasi…
Plasma instability in the afterglow of electron cyclotron resonance discharge sustained in a mirror trap
2012
The work presented in this article is devoted to time-resolved diagnostics of non-linear effects observed during the afterglow plasma decay of a 14 GHz electron cyclotron resonance ion source operated in pulsed mode. Plasma instabilities that cause perturbations of the extracted ion current during the decay were observed and studied. It is shown that these perturbations are associated with precipitation of high energy electrons along the magnetic field lines and strong bursts of bremsstrahlung emission. The effect of ion source settings on the onset of the observed instabilities was investigated. Based on the experimental data and estimated plasma properties, it is assumed that the instabil…
A status report of the multipurpose superconducting electron cyclotron resonance ion source
2007
Intense heavy ion beam production with electron cyclotron resonance (ECR) ion sources is a common requirement for many of the accelerators under construction in Europe and elsewhere. An average increase of about one order of magnitude per decade in the performance of ECR ion sources was obtained up to now since the time of pioneering experiment of R. Geller at CEA, Grenoble, and this trend is not deemed to get the saturation at least in the next decade, according to the increased availability of powerful magnets and microwave generators. Electron density above 1013 cm(-3) and very high current of multiply charged ions are expected with the use of 28 GHz microwave heating and of an adequate …