Search results for "electronics"
showing 10 items of 4340 documents
Experimental Investigation of Fused Biconical Fiber Couplers for Measuring Refractive Index Changes in Aqueous Solutions
2016
A detailed experimental study of a simple and compact fiber optic sensor based on a fused biconical fiber coupler is presented, in which the sensitivity is improved by operating the coupler beyond the first coupling cycle. The sensor is demonstrated to perform high sensitivity measurements of refractive index changes by means of variation of sugar concentration in water. The device is operated to achieve a linear transmission response, allowing a linear relation between the sugar concentration and the output signal. The initial sensitivity was measured as 0.03 units of normalized transmission per unit of sugar concentration (g/100 mL), with a noise detection limit of a sugar concentration o…
Flow-injection spectrophotometric determination of arylamines and sulphonamides by diazotization and coupling in a micellar medium
1991
Abstract In a sodium dodecyl sulphate (SDS) micellar solution, the rate of coupling of a diazonium ion with N-(1- naphthyl)ethylenediamine (NED) increases greatly, the protonation of the resulting azo dyes takes place at higher pH values and the dyes are more soluble. These favourable features were applied to the development of a simple flow-injection spectrophotometric procedure for the determination of diazotizable substances of pharmaceutical interest. Limits of detection in the range 0.2–0.5 μg ml−1 (signal-to-noise ratio=3), with relative standard deviation of 0.7–3% (n=3) for 5 μg ml−1 standards, were obtained.
Enhanced nanoscopy of individual CsPbBr3 perovskite nanocrystals using dielectric sub-micrometric antennas
2020
We demonstrate an efficient, simple, and low-cost approach for enhanced nanoscopy in individual green emitting perovskite (CsPbBr3) nanocrystals via TiO2 dielectric nanoantenna. The observed three- to five-fold emission enhancement is attributed to near-field effects and emission steering promoted by the coupling between the perovskite nanocrystals and the dielectric sub-micrometric antennas. The dark-field scattering configuration is then exploited for surface-enhanced absorption measurements, showing a large increase in detection sensitivity, leading to the detection of individual nanocrystals. Due to the broadband spectral response of the Mie sub-micrometric antennas, the method can be e…
Conceptual design of the TRACE detector readout using a compact, dead time-less analog memory ASIC
2015
[EN] The new TRacking Array for light Charged particle Ejectiles (TRACE) detector system requires monitorization and sampling of all pulses in a large number of channels with very strict space and power consumption restrictions for the front-end electronics and cabling. Its readout system is to be based on analog memory ASICs with 64 channels each that sample a View the MathML source window of the waveform of any valid pulses at 200 MHz while discarding any other signals and are read out at 50 MHz with external ADC digitization. For this purpose, a new, compact analog memory architecture is described that allows pulse capture with zero dead time in any channel while vastly reducing the tota…
A New Software Tool for Design, Optimization, and Complete Analysis of Rotating Electrical Machines Windings
2015
In this paper, a new software tool developed by the authors for ac winding design, optimization, and complete analysis is presented. In particular, this software can be used as a valid aid in design and analysis for a wide variety of motor and generator windings with generic number of phases (including the case of those machines in which some slots are left empty), pole pairs, slot number, and so on. The calculation of winding factors and the evaluation of their harmonic distribution is also accomplished. The software is implemented in the MATLAB programming environment. By means of some examples, covering the most relevant winding types, the capabilities of this software will be shown. In …
<title>Holographic recording in amorphous semiconductor films</title>
1997
The present state of the real time holographic recording in amorphous semiconductor films is reviewed including mechanisms, parameters, properties and applications. Effects of the coherent, incoherent and relaxational self- enhancement as well as the influence of the film structure relaxation are considered. Quasi-permanent sub-band-gap light holographic recording is reported for the first time. 157
Diffractive optics for spectral tuning of second harmonic and supercontinuum generated in nonlinear crystals
2011
It is shown that diffractive lenses can tune the spectrum of femtosecond pulses after nonlinear optical processes. We focus on spectra of second-order pulses generated in birefringent crystals and supercontinuum in sapphire crystals. The tunability is achieved by changing the relative distance between the nonlinear crystal and the diffractive lens.
Growth temperature influence on the GaN nanowires grown by MOVPE technique
2011
GaN nanowires (NWs) were successfully grown by Vapor-Liquid-Solid (VLS) growth mechanism on GaN template using metal-organic vapor phase epitaxy (MOVPE) with diameters ranging from 20 to 200 nm and length up to few microns. The characterization by scanning electron microscopy (SEM) reveals an optimum growth temperature at 790°C and X-ray diffraction (XRD) investigations indicates oriented crystallinity of grown NWs.
A new interpretation of the 22-tricosenoic acid Langmuir-Blodgett structures identified as triclinic by Rheeds
1990
Abstract One of the original structural studies on Langmuir-Blodgett (LB) multilayers of 22-tricosenoic acid using the technique of reflection high-energy electron diffraction was performed by Peterson and Russell (1984, Phil. Mag. A, 49, 463). In their paper, four distinct structural arrangements of the long-chain fatty acid were identified, where the arrangement adopted by a particular sample was found to depend on the substrate and deposition conditions. The identification of the C2 H4 subcells in each of these arrangements was made on the basis of a number of assumptions, some of which have subsequently been shown to be erroneous. In particular, the identification of a triclinic subcell…
X‐ray characterization of CdO thin films grown on a ‐, c ‐, r ‐ and m ‐plane sapphire by metalorganic vapour phase‐epitaxy
2005
CdO thin films have been grown on a-plane (110), c-plane (0001), r-plane (012) and m-plane (100) sapphire substrates by metalorganic vapour-phase epitaxy (MOVPE). The effects of different substrate orientations on the structural properties of the films have been analyzed by means of X-ray diffraction, including θ-2θ scans, pole figures and rocking curves. (111), (001) and (110) orientations are found on a-, r-, and m-sapphire respectively, while films deposited on c-plane exhibit an orientation in which no low-index crystal plane is parallel to the sample surface. The recorded pole figures have allowed determining the epitaxial relationships between films and substrates, as well as the pres…