Identification of optimal device combinations for the chimney endovascular aneurysm repair technique within the PERICLES registry
2018
Abstract Objective The ideal stent combination for chimney endovascular aneurysm repair remains undetermined. Therefore, we sought to identify optimal aortic and chimney stent combinations that are associated with the best outcomes by analyzing the worldwide collected experience in the PERformance of chImney technique for the treatment of Complex aortic pathoLogiES (PERICLES) registry. Methods The PERICLES registry was reviewed for patients with pararenal aortic disease electively treated from 2008 to 2014. Eleven different aortic devices were identified with three distinct subgroups: group A (n = 224), nitinol/polyester; group B (n = 105), stainless steel/polyester; and group C (n = 69), n…
Endovascular Aneurysm Sealing (EVAS) and Chimney EVAS in the Treatment of Failed Endovascular Aneurysm Repairs
2016
Purpose: To assess the technical success and clinical outcome of reinterventions using the Nellix Endovascular Aneurysm Sealing (EVAS) System to treat complications after endovascular aneurysm repair (EVAR). Methods: Fifteen consecutive patients (mean age 79 years; 14 men) with prior EVAR were treated with EVAS between March 2014 and December 2015 at 2 institutions. The failed prior EVARs included 13 bifurcated endografts, 1 bifurcated graft plus fenestrated cuff, and 1 tube endograft. Endoleaks were the predominant indications: type Ia in 10 and type III in 5 (3 type IIIa and 2 type IIIb). All patients presented with progressive aortic aneurysms (median 7.85-cm diameter; range 6.5–11). Ei…
A multicenter 12-month experience with a new iliac side-branched device for revascularization of hypogastric arteries.
2016
Abstract Objective The aim of this study was to investigate the 1-year safety and efficacy of a new iliac side-branched device (IBD) for revascularization of the hypogastric arteries. Methods Patients receiving the E-liac (Jotec GmbH, Hechingen, Germany) side-branched device at six German vascular centers either as a stand-alone procedure or in combination with abdominal aortic aneurysm exclusion were included in a prospectively created data bank. Collected data were analyzed for baseline characteristics, procedural events, and clinical follow-up; variables included endoleaks, reinterventions, and internal iliac artery (IIA) patency. Results Between January 2012 and January 2015, a total of…
A 15-Year Single-Center Experience of Endovascular Repair for Elective and Ruptured Abdominal Aortic Aneurysms
2016
Purpose: To evaluate the differences in technical outcomes and secondary interventions between elective endovascular aneurysm repair (el-EVAR) procedures and those for ruptured aneurysms (r-EVAR). Methods: Of the 906 patients treated with primary EVAR from September 1998 until July 2012, 43 cases were excluded owing to the use of first-generation stent-grafts. Among the remaining 863 patients, 773 (89.6%) patients (mean age 72 years; 697 men) with asymptomatic or symptomatic abdominal aortic aneurysms (AAAs) were assigned to the el-EVAR group; 90 (10.4%) patients (mean age 73 years; 73 men) were assigned to the r-EVAR group based on blood outside the aortic wall on preoperative imaging. Th…
Mid-term Results of Chimney and Periscope Grafts in Supra-aortic Branches in High Risk Patients
2017
Purpose Report mid-term outcomes of thoracic endovascular aneurysm repair (TEVAR) with chimney and periscope grafts (CPG) in supra-aortic branches (SAB). Methods Retrospective analysis, from October 2009 to May 2014, of patients with aneurysms requiring TEVAR with zone 0/1/2 proximal landing in association with at least one CPG in the SAB. All patients were considered at high risk for conventional surgery. Peri-operative mortality and morbidity, retrograde type A dissection, maximum aortic transverse diameter (TD) and its post-operative evolution, endoleak, survival, freedom from cardiovascular re-interventions, and CPG freedom from occlusion during the follow-up were analysed. Results Fort…
Hybrid Endograft Solution for Complex Iliac Anatomy
2010
The purpose of this study was to evaluate single-center results with selective use of Gore Excluder limbs (W.L. Gore & Associates, Flagstaff, AZ) in a Cook Zenith body (Cook Inc, Bloomington, IN) for elective endovascular abdominal aortic aneurysm (AAA) repair. A prospectively held database for patients with AAA, who were treated endovascularly between March 1999 and July 2008, was queried for patients treated with a Cook Zenith body and one or two Gore Excluder limbs. Indication, technical success, late limb occlusion, and disconnection were evaluated. From 276 patients who were treated with a Zenith body, 29 underwent repair with hybrid graft components with, in total, 41 Gore Exclud…
Peroperative Intravascular Ultrasound for Endovascular Aneurysm Repair versus Peroperative Angiography: A Pilot Study in Fit Patients with Favorable …
2020
The aim of this study was to compare intravascular ultrasound (IVUS) assistance for endovascular aortic aneurysm repair (EVAR) to standard assistance by angiography.From June 2015 to June 2017, 173 consecutive patients underwent EVAR. In this group, 69 procedures were IVUS-assisted with X-ray exposure limited to completion angiography for safety purposes because an IVUS probe does not yet incorporate a duplex probe (group A), and 104 were angiography-assisted procedures (group B). All IVUS-assisted procedures were performed by vascular surgeons with basic duplex ultrasound (DUS) training. The primary study endpoints were mean radiation dose, duration of fluoroscopy, amount of contrast media…
Collected Transatlantic Experience From the PERICLES Registry: Use of Chimney Grafts to Treat Post-EVAR Type Ia Endoleaks Shows Good Midterm Results
2018
Purpose: The aim of this retrospective analysis was to evaluate the performance of the chimney (ch) technique in the treatment of type Ia endoleaks after standard endovascular aneurysm repair (EVAR). Methods: Between January 2008 and December 2014, 517 chEVAR procedures were performed in 13 US and European vascular centers (PERICLES registry). Thirty-nine patients (mean age 76.9±7.1 years; 33 men) were treated for persistent type Ia endoleak and had computed tomography angiography or magnetic resonance angiography follow-up at >1 month. Endurant abdominal stent-grafts were used in the 20 cases. Single chimney graft placement was performed in 18 (46%) patients and multiple in 21 (54%). O…
Single-centre experience and preliminary Results of intravascular ultrasound in endovascular aneurysm repair
2019
Background Intravascular ultrasound (IVUS) has been introduced as diagnostic adjunct to provide new insights into the diagnosis and therapy of vascular disease. Herein, we compared the outcomes of conventional endovascular aneurysm repair (EVAR) and EVAR with IVUS in patients presenting with infrarenal abdominal aortic aneurysm using a propensity-matched cohort. Methods From May 2013 to August 2017, 221 patients were retrospectively analyzed. Of that, 122 patients were eligible for inclusion and underwent propensity score matching. Perioperative mortality and morbidity, renal function impairment, endoleak incidence, mean contrast medium usage, operative time, radiation exposure (including f…
Fenestrated Stent Grafting for Short-necked and Juxtarenal Abdominal Aortic Aneurysm
2010
Objectives: To present an 8-year clinical experience in the endovascular treatment of short-necked and juxtarenal abdominal aortic aneurysm (AAA) with fenestrated stent grafts. Methods: At our tertiary referral centre, all patients treated with fenestrated and branched stent grafts have been enrolled in an investigational device protocol database. Patients with short-necked or juxtarenal AAA managed with fenestrated endovascular aneurysm repair (F-EVAR) between November 2001 and April 2009 were retrospectively reviewed. Patients treated at other hospitals under the supervision of the main author were excluded from the study. Patients treated for suprarenal or thoraco-abdominal aneurysms wer…