Search results for "error"
showing 10 items of 1643 documents
Explicit and implicit memory biases in depression and panic disorder.
2000
The purpose of the present study was to investigate the presence of a bias for emotional information (panic-related, depression-related, positive and neutral) in explicit memory and implicit memory (by means of free recall and word-stem completion tasks, respectively) among depressed (N=20) and panic (N=20) patients. Three different encoding conditions (graphemic, semantic and self-reference) were used. The results of this study failed to show the existence of a mood-congruent memory bias for both implicit and explicit memory in these emotional disorders. According to the correlational analyses performed, differences among categories of emotional words meant less than the difference among v…
The processing of mispredicted and unpredicted sensory inputs interact differently with attention
2018
International audience; Prediction and attention are fundamental brain functions in the service of perception. Interestingly, previous investigations found prediction effects independent of attention in some cases but attention-dependent in other cases. The discrepancy might be related to whether the prediction effect was revealed by comparing mis-predicted event (where there is incorrect prediction) or unpredicted event (where there is no precise prediction) against predicted event, which are associated with different precision-weighted prediction error. Here we conducted a joint analysis on four published electroencephalography (EEG) datasets which allow for proper dissociation of mispred…
Estimated radiation exposure of German commercial airline cabin crew in the years 1960-2003 modeled using dose registry data for 2004-2015.
2016
Exposure to ionizing radiation of cosmic origin is an occupational risk factor in commercial aircrew. In a historic cohort of 26,774 German aircrew, radiation exposure was previously estimated only for cockpit crew using a job-exposure matrix (JEM). Here, a new method for retrospectively estimating cabin crew dose is developed. The German Federal Radiation Registry (SSR) documents individual monthly effective doses for all aircrew. SSR-provided doses on 12,941 aircrew from 2004 to 2015 were used to model cabin crew dose as a function of age, sex, job category, solar activity, and male pilots' dose; the mean annual effective dose was 2.25 mSv (range 0.01–6.39 mSv). In addition to an inverse …
Suppression of the cardiac electric field artifact from the heart action evoked potential
2006
The study of heart action-related brain potentials is strongly disrupted by the presence of an inherent cardiac electric artifact. The hypothesis is presented that most of the electric current coupled to the cardiac field surrounds the skull and flows through the scalp tissue without crossing the cranial cavity. This pseudo two-dimensional conduction model contrasts with the volumetric conduction of the brain electrical activity, and this property is exploited to cancel the cardiac electric artifact. QRS loop vector-cardiographic projections on saggital planes were recorded in 11 healthy subjects in the head and neck areas. Comparative analysis of the projection eccentricities, estimated by…
Cholinesterase variants: rapid characterisation by PCR/SSCP and evidence for molecular homogeneity.
1995
We have applied the technique of PCR-SSCP (polymerase chain reaction-single stranded conformation polymorphism) to characterise the molecular basis of cholinesterase deficiency and variants in a Jordanian family. PCR-SSCP proved to be a quick and sensitive method of screening cholinesterase variants in a clinical setting. An AG insertion at position 351 was found to cause a silent allele, for which the parents were heterozygous and three children homozygous. In addition, the father and two sons were heterozygous for an A to G transition at position 209, known to cause the dibucaine resistant variant. No linkage to the K variant was found, which has been reported previously in white populati…
Posterior chamber phakic intraocular lenses to correct high myopia: A comparative study between Staar and Adatomed models
2001
ABSTRACT PURPOSE: To determine the feasibility of using posterior chamber phakic intraocular lenses (PIOLs) to treat high myopia, comparing two different models, Staar and Adatomed. METHODS: Twenty-four eyes from 12 patients were studied prospectively. A phakic Staar IOL was implanted in one eye of each patient, and the other eye received a phakic Adatomed IOL. Patients with uveitis or ocular trauma prior to ocular surgery, diabetic retinopathy, or capsular pseudoexfoliation were excluded. The mean preoperative spherical equivalent refraction was -16.00 ± 5.05 D for the Staar group and -15.39 ± 2.83 D for the Adatomed group. Average follow-up was 32.4 months (range, 19 to 46 mo) for the Ada…
Intraocular pressure after excimer laser myopic refractive surgery
2001
The aim of this study was to determine whether intraocular pressure (IOP), as measured by Goldmann applanation or non-contact tonometry, shows systematic changes in patients who have undergone photorefractive keratectomy (PRK) or laser in situ keratomileusis (LASIK). IOP was measured by central Goldmann and non-contact tonometry in 54 patients pre and post-PRK, and in 43 patients pre- and post-LASIK. An interval of 12 months was allowed after surgery. Patients were selected to have one of four specific initial values of refractive error (-2.5, -5.0, -7.5 and -10.0 D). Fellow unoperated eyes were used as controls. A paired Student's t-test and a one-way ANOVA test were used for statistical a…
Subjective Satisfaction in Long-term Orthokeratology Patients
2013
Purpose: To AU3 evaluate the subjective satisfaction in visual stability, night vision complains, and light distortion phenomena, and also the number of hours and days per week of lens wear, in patients with myopia undergoing orthokeratology (OK) treatment for at least 1 year. Methods: A visual analog scale (VAS) questionnaire containing 18 items was administered to 44 patients, 29 women and 15 men (mean age, 24.39 6 9.11 years), with a baseline spherical equivalent refractive error of 22.40 6 0.94 diopters and astigmatism up to 20.5 diopters. Average treatment period by the time of data collection was 19 6 7 months. Patients rated their satisfaction with the correction, with complaints of …
Light distortion of soft multifocal contact lenses with different pupil size and shape
2020
Purpose: To study the light distortion effects of soft multifocal contact lenses and the influence of different pupil size and shape.Methods: A total of 14 eyes of 7 healthy contact lens users (mean age 28.6 +/- 8.5 years) were recruited. The "Light Disturbance Analyser" device was employed for light characterization. The selected lenses were the monthly disposable "Biofinity multifocal" (CooperVision, CA, USA), both centre-distance and centre-near designs (addition power + 2.50 D). Two circular pupils of 3 mm and 5 mm of diameter, and an elliptical shape (3 horizontal and 5 vertical mm) were used. Metrics such as the light distortion index (LDI), best-fit circle radius and its irregularity…
EMG, heart rate, and accelerometer as estimators of energy expenditure in locomotion.
2014
AB Purpose: Precise measures of energy expenditure (EE) during everyday activities are needed. This study assessed the validity of novel shorts measuring EMG and compared this method with HR and accelerometry (ACC) when estimating EE. Methods: Fifty-four volunteers (39.4 +/- 13.9 yr) performed a maximal treadmill test (3-min loads) including walking with different speeds uphill, downhill, and on level ground and one running load. The data were categorized into all, low, and level loads. EE was measured by indirect calorimetry, whereas HR, ACC, and EMG were measured continuously. EMG from quadriceps (Q) and hamstrings (H) was measured using shorts with textile electrodes. Validity of the met…