Search results for "extreme"
showing 10 items of 319 documents
Extremely low frequency band station for natural electromagnetic noise measurement
2015
A new permanent ELF measurement station has been deployed in Sierra Nevada, Spain. It is composed of two magnetometers, oriented NS and EW, respectively. At 10 Hz, their sensitivity is 19 μV/pT and the signal-to-noise ratio (SNR) is 28 dB for a time-varying signal of 1 pT, the expected field amplitude in Sierra Nevada. The station operates for frequencies below 24 Hz. The magnetometers, together with their corresponding electronics, have been specifically designed to achieve such an SNR for small signals. They are based on high-resolution search coils with ferromagnetic core and 106 turns, operating in limited geometry configuration. Different system noise sources are considered, and a stud…
Laser driven structured quantum rings
2015
In this work we study harmonic emission from structured quantum rings (SQRs). In SQRs, electrons trapped in two-dimensional structures are further confined by an external potential composed of N scattering centers arranged on a circle. We build a suitable one-dimensional model Hamiltonian describing this class of systems and analytically solve the associated Schödinger equation. We find that the solution can be expressed in terms of Mathieu functions and focus on the specific case of N = 6. By exactly solving the time-dependent Schödinger equation, we then show how the harmonic response to linearly polarized lasers strongly depends on the ring physical parameters. The results illustrate how…
LASERIX: an open facility for developments of Soft X-ray and EUV lasers and applications
2011
In this paper we report the perspectives of the development of the XUV laser sources and applications using High-power laser facilities. We focus our paper on the present status of the French LASERIX facility and more especially about its role in the development of the XUV laser sources considering the French "Institut de la Lumiere Extreme " (ILE) and the potential European project Extreme Light Infrastructure (ELI). Finally, we present the scientific perspectives of X-ray laser sources developments using these laser facilities.
Towards high photon-number soft x-ray lasers
2011
We present an experimental design to independently pump two soft X-ray laser media suitable for a seed-amplifier configuration. Both the seed and the amplifier target are operated in the TCE scheme utilizing the DGRIP technique with its intrinsic travelling wave excitation. Controlled injection of the seed X-ray laser into the amplifier medium is realized via a spherical XUV mirror. The experimental design is perfectly appropriate for benchmarking combined simulations of the ARWEN and DeepOne code. A first experiment at the PHELIX laser utilizing this scheme has been conducted, demonstrating signs of amplification and allowing for the direct measurement of the gain life time of a Ni-like si…
Coronal loop hydrodynamics. The solar flare observedon November 12 1980 revisited: the UV line emission
2001
We revisit a well-studied solar flare whose X-ray emission originating from a simple loop structure was observed by most of the instruments on board SMM on November 12 1980. The X-ray emission of this flare, as observed with the XRP, was successfully modeled previously. Here we include a detailed modeling of the transition region and we compare the hydrodynamic results with the UVSP observations in two EUV lines, measured in areas smaller than the XRP rasters, covering only some portions of the flaring loop (the top and the foot-points). The single loop hydrodynamic model, which fits well the evolution of coronal lines (those observed with the XRP and the \FeXXI 1354.1 \AA line observed wit…
SphinX: A fast solar Photometer in X-rays
2008
The scientific goals and construction details of a new design, Polish X-ray spectrophotometer are given. It will be incorporated within the Russian TESIS X and EUV complex aboard the forthcoming CORO-NAS solar mission. SphinX (Solar Photometer in X-rays) will use PIN silicon detectors for high time resolution (0.01 s) measurements of the solar spectra of quiet and active corona in the range 0.5–15 keV. A new filter-fluorescence target concept will be employed to allow for a fast photometry of the solar X-ray flux variations in selected, well defined narrow spectral bands including the Fe XXVI and Fe XXV iron line groups.
Thermal structure of a hot non-flaring corona from Hinode/EIS
2014
In previous studies a very hot plasma component has been diagnosed in solar active regions through the images in three different narrow-band channels of SDO/AIA. This diagnostic from EUV imaging data has also been supported by the matching morphology of the emission in the hot Ca XVII line, as observed with Hinode/EIS. This evidence is debated because of unknown distribution of the emission measure along the line of sight. Here we investigate in detail the thermal distribution of one of such regions using EUV spectroscopic data. In an active region observed with SDO/AIA, Hinode/EIS and XRT, we select a subregion with a very hot plasma component and another cooler one for comparison. The ave…
Extreme events in fiber based amplifiers
2009
International audience; We present experimental and theoretical results showing the emergence of rogue wave-like extreme intensity spikes during fiber-based amplification processes such as Raman effect or induced-modulational instability that rely on quasi-instantaneous gain. We outline that under certain circumstances, a partially incoherent pumping can induce large fluctuations of the amplified signal, and we propose various means to spectrally select the most extreme structures.
Laser driven parametric amplification of xuv and soft-x-rays in neutral gases
2010
We present the first theoretical description and also experimental evidence for the amplification of XUV and soft-X-ray radiation by parametric stimulated emission in neutral gases driven by near-IR laser pulses reaching small-signal-gain up to 8000.
Developments on the 1.4 MeV/u Pulsed Gas Stripper Cell
2017
The GSI UNILAC in combination with SIS18 will serve as a high-current, heavy-ion injector for the FAIR facility. It must meet high demands in terms of beam brilliance at a low duty factor. As part of an UNILAC upgrade program dedicated to FAIR, a new pulsed gas stripper cell was developed, aiming for increased beam intensities inside the post-stripper. The pulsed gas injection is synchronized with the beam pulse timing, enabling a highly-demanded, increased gas density. First tests using uranium beams on a hydrogen target showed a 60%-increased stripping efficiency into the desired 28+ charge state. In 2015, the setup was improved to be able to deliver increased target thicknesses and enhan…