Search results for "flame"
showing 10 items of 108 documents
High-resolution pyrolysis–gas chromatography with a movable reaction zone
1997
Abstract A new device was constructed for pyrolysis–gas chromatography and it was laboratory tested. The device enables the thermal degradation of polymers inside a capillary pre-column and transfer of the reaction zone into a column oven. The pyrolysis procedure described protects the thermally sensitive compounds prior to pyrolysis, prevents the process of irreversible condensation of high-boiling pyrolysis products during the chromatographic process and eliminates extracolumn effects on the peak broadening.
Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples
2016
Few methods are available for comprehensive organophosphate flame retardants (PFRs) detection in water and wastewater. Gas chromatography has been employed previously, but this approach is less selective, not amenable for use with deuterated standards and can suffer unfavorable fragmentation. Ultra-high-pressure liquid chromatography tandem mass spectrometry (UHPLC-QqQ-MS/MS) has become the most promising platform, already applied successfully for analysis of selected PFRs in some environmental matrices like water and wastewater. However, the presence of some interferences from the dissolvent, the equipment and the used materials should be taken into account. The procedure involves: The fir…
Lipid hydroperoxides determination in milk‐based infant formulae by gas chromatography
2003
A simple gas chromatograph using a flame ionization detector and a polar capillary column method is proposed for determining hydroperoxides in the lipid fraction of milkbased infant formulas. Tricosanoic acid is used as internal standard. The method includes the following steps: a) the extraction of fat with chloroform/methanol (2:1, v/v), b) the reduction of hydroperoxide acids to hydroxide acids with hydrogen gas and palladium as a catalyst, c) the transmethylation to obtain the methyl esters with acetyl chloride and methanol/ hexane (4:1, v/v), and d) an acetylation with acetic anhydride/ pyridine (4:1, v/v) to obtain an acetoxy derivate of the hydroxide present. Two chromatography runs,…
Determination of triazines and organophosphorus pesticides in water samples using solid-phase extraction.
1991
Abstract Octadecyl (C 18 )-bonded porous silica was evaluated for the extraction of triazine and organophosphorus pesticides from natural water. The extraction results showed an effective performance when 1 l of water was passed through small glass columns containing 500 mg of 50–100-μm C 18 bonded porous silica. The absorbed compounds were removed with ethyl acetate, evaporated to 200 μl and determined by gas chromatography. The overall average recoveries were greater than 85% except for dimethoate and trichlorfon. Application of this procedure to the analysis of natural water samples gave results that agree well with those obtained by solvent extraction methods.
Gas chromatographic separation of acetylated chlorinated phenols, guaiacols and catechols on an SE-30 quartz capillary column
1983
Supercritical Fluid Extraction and Supercritical Fluid Chromatography of Vitamin E in Pharmaceutical Preparations
1999
Overlapped moving windows followed by principal component analysis to extract information from chromatograms and application to classification analys…
2015
Variable generation from chromatograms is conveniently accomplished using unsupervised rather than manual techniques. With unsupervised techniques, there is no need for selecting a few peaks for manual integration and valuable information is quickly and efficiently collected. The generation of variables can be performed by using either peak searching or moving window (MW) strategies. With a MW approach, the peaks are ignored and many variables, only part of them carrying information, are generated. Thus, variable generation by MWs should be followed by data compression to generate the variables to be further used for classification or quantitation purposes. In this work, unsupervised proces…
Identification of lipid binders in paintings by gas chromatography
2001
Abstract The influence of the presence and the type of pigments in the lipid binding media of paintings were studied by gas chromatography with flame ionization detector. The drying oils were linseed stand oil, poppy oil and sunflower oil, and the pigments studied were cadmium red, cobalt blue, tin white, lead white, chalk and plaster of Paris, commonly used in paintings. The results indicate that the stearic/palmitic ratio and the presence of pigments are quite stable during ageing. However, some differences in the oleic acid/palmitic acid ratio were found, depending on the type of pigment present in the lipid binding media. These variations are related to the drying effect of the pigments…
Structural clustering of millions of molecular graphs
2014
We propose an algorithm for clustering very large molecular graph databases according to scaffolds (i.e., large structural overlaps) that are common between cluster members. Our approach first partitions the original dataset into several smaller datasets using a greedy clustering approach named APreClus based on dynamic seed clustering. APreClus is an online and instance incremental clustering algorithm delaying the final cluster assignment of an instance until one of the so-called pending clusters the instance belongs to has reached significant size and is converted to a fixed cluster. Once a cluster is fixed, APreClus recalculates the cluster centers, which are used as representatives for…
On-line bidirectional electrostacking of chromium(III) and chromium(VI) for flame atomic absorption spectrometry determination
2000
Abstract An on-line bidirectional electrostacking-flow injection-flame atomic absorption spectrometry method has been developed for the simultaneous separation, pre-concentration and determination of Cr(III) and Cr(VI). The electrostacking-flow injection unit was established, the pH and components of the support buffer and sample medium were investigated. Results indicated that the ionic mobility, electric field strength and sample area cross-section are the main influence factors on the electrostacking. The calibration range for both, Cr(III) and Cr(VI), was from 20 to 400 μg l −1 . The limit of detection was 7 μg l −1 for three-times the standard deviation of blank values using a electros…