Preconcentration of aluminium by micellar-enhanced ultrafiltration
1993
Abstract Traces of aluminium were preconcentrated in water samples by forming a complex with lumogallion, and successfully accumulated in the micellar phase obtained from cationic or non-ionic surfactants and filtered through 10 000 molecular weight cut-off ultrafiltration membranes. Studies indicated that, at pH 5.9, with 1 X 10 −3 M lumogallion and 2 X 10 −2 M cetyltrimethylamonium bromide, quantitative retention of aluminium present at μg ml −1 concentration levels was achieved. A micellar-enhanced fluorimetric procedure was employed to analyse the permeate solutions, whereas nitrous oxide-acetylene flame atomic emission spectrometry was used to determine aluminium in the retentate. The …
Control of propranolol intake by direct chromatographic detection of alpha-naphthoxylactic acid in urine.
2002
A rapid chromatographic procedure with a C18 column, a mobile phase of 0.15 M sodium dodecyl sulfate (SDS)-10% (v/v) 1-propanol at pH 3 (0.01 M phosphate buffer), and fluorimetric detection, is reported for the control of propranolol (PPL) intake in urine samples, which are injected directly without any other treatment than filtration. The peak of PPL was only observed in samples taken a few hours after ingestion of the drug due to its extensive conjugation and metabolisation. The detection of several unconjugated PPL metabolites was therefore considered: desisopropylpropranolol (DIP), propranolol glycol (PPG), alpha-naphthoxylactic acid (NLT) and alpha-naphthoxyacetic acid (NAC). NLT showe…
Application of solid-phase microextraction combined with derivatization to the enantiomeric determination of amphetamines.
2005
Abstract The utility of combining chiral derivatization and solid-phase microextraction (SPME) for the enantiomeric analysis of primary amphetamines by liquid chromatography has been investigated. Different derivatization/extraction strategies have been evaluated and compared using the chiral reagent o -phthaldialdehyde (OPA)– N -acetyl- l -cysteine (NAC) and fibres with a Carbowax-templated resin coating. Amphetamine, norephedrine and 3,4-methylenedioxyamphetamine (MDA) were used as model compounds. On the basis of the results obtained, a new method is presented based on the derivatization of the analytes in solution followed by SPME of the OPA–NAC derivatives formed. The proposed conditio…
Determination of triamterene and its main metabolite hydroxytriamterene sulfate in human urine by capillary electrophoresis using ultraviolet absorba…
2002
Abstract Two capillary electrophoresis methods have been developed for the direct determination of triamterene and its main metabolite hydroxytriamterene sulfate in human urine. Analytes were detected using conventional UV detection as well as laser-induced fluorescence (LIF) detection with an HeCd-laser operating at a wavelength of 325 nm. The results of both detection techniques were compared. Indeed, the limit of quantification was eightfold lower using LIF detection (50 ng/ml) in comparison to UV detection (400 ng/ml). As no interference due to endogenous urine compounds was observed, direct urine analysis was feasible. Analysis was very simple and fast—one run could be performed within…
Supramolecular Chemical Sensors Based on Pyrene Monomer-Excimer Dual Luminescence
2010
The past ten years have seen a spectacular development of chemical sensors based on the monomer-excimer dual luminescence of aromatic systems, such as pyrene. Either in the form of integrated or multicomponent molecular devices these chemosensors have been attracting a high interest above all because of their unique ratiometric properties. This review will focus on the latter systems, which can be classified into two classes: Firstly, the assembly of receptor-effector conjugates is triggerred by the analyte of interest. As a result, the sensor shows monomer to excimer fluorescence switching upon substrate binding. Secondly, the supramolecular assembly that constitutes the sensor is perturbe…
Analytical strategies to determine quinolone residues in food and the environment
2007
23 páginas, 5 figuras, 5 tablas.
More about sampling and estimation of mercaptans in air samples
2013
[EN] Several strategies have been developed for sampling and determination of volatile thiols. The selectivity and sensitivity of the proposed methodologies are achieved by using a specific derivatizing reagent. The different procedures assayed are based on air sampling followed by derivatization of the analytes with OPA and isoleucine in alkaline solution. The derivatization products are separated and determined by liquid chromatography and fluorescence detection. To start, the derivatization conditions and stability of the derivates have been studied in order to establish the storage conditions. In general, the strategies studied consisted on trapping and detivatization the thiol compound…
A taylor series model to evaluate the interelemental effects in X-ray fluorescence analysis, applied to the iron-zirconium-diluent system
1995
A semi-empirical model has been developed to quantify the interelemental effects in X-ray fluorescence analysis. The measured X-ray fluorescence intensity has been expressed as a function of the different fluorescence elements composing the sample. this complex function has become an operative function via a Taylor series development. An explication has been given for the significance of the different terms of the series. These terms respond to mathematical functions known as characteristic functions for each chemical system. A parameter (B) has been defined which makes it possible to quantify the influence of the interelemental effect as a function of the analyte concentration (C) and that…
ChemInform Abstract: Supramolecular Chemical Sensors Based on Pyrene Monomer-Excimer Dual Luminescence.
2011
The past ten years have seen a spectacular development of chemical sensors based on the monomer-excimer dual luminescence of aromatic systems, such as pyrene. Either in the form of integrated or multicomponent molecular devices these chemosensors have been attracting a high interest above all because of their unique ratiometric properties. This review will focus on the latter systems, which can be classified into two classes: Firstly, the assembly of receptor-effector conjugates is triggerred by the analyte of interest. As a result, the sensor shows monomer to excimer fluorescence switching upon substrate binding. Secondly, the supramolecular assembly that constitutes the sensor is perturbe…
Soret emission from water-soluble porphyrin thin films: effect on the electroluminescence response
2009
The emission properties of TSPP [tetrakis(4-sulfonatophenyl) porphyrin] and TMPyP [tetrakis(4-methylpyridyl) porphyrin] in thin films, prepared both by the Langmuir–Blodgett technique and the spin-coating method, have been investigated. Surprisingly, in most of the samples analyzed, the emission spectra do not show the usual two bands typical of porphyrins (in the region 650–750 nm), and depend strongly on the excitation energy. The origin of a new emission band detected at ∼480–500 nm is discussed in terms of the nature of the porphyrin aggregates. Moreover, we demonstrate that the presence or absence of this band in the fluorescence spectrum is directly related to the generation of electr…