Search results for "fourier"

showing 10 items of 1345 documents

Inulin-Ethylenediamine Coated SPIONs Magnetoplexes: A Promising Tool for Improving siRNA Delivery.

2015

An inulin based polycation (Inu-EDA) has been synthesized by the grafting of ethylenediamine molecules onto inulin backbone. The obtained inulin copolymer has been though to coat SPIONs (IC-SPIONs) and obtain stable magnetoplexes by complexation of IC-SPIONs with a model duplexed siRNA, for improving oligonucleotide transfection efficiency.The physical-chemical characteristics of IC-SPIONs and IC-SPIONs/siRNA magnetoplexes have been investigated by scanning and transmission electron microscopies, dynamic light scattering, FT-IR and qualitative surface elementary analysis. Cell compatibility and internalization in vitro of IC-SPIONs have been evaluated by MTS and fluorescence microscopy resp…

Cell SurvivalSurface PropertiesDrug CompoundingInulinPharmaceutical ScienceTransfectionpolycationchemistry.chemical_compoundDynamic light scatteringMicroscopy Electron TransmissionSpectroscopy Fourier Transform InfraredFluorescence microscopeHumansPharmacology (medical)Particle SizeRNA Small InterferingMagnetite NanoparticlesPharmacologyDrug CarriersChemistryOligonucleotideOrganic ChemistryInulinTransfectionEthylenediaminesHCT116 CellsIn vitroFerrosoferric OxideSPIONsTargeted drug deliveryBiochemistryCell cultureinulin; magnetoplexes; polycation; siRNA; SPIONssiRNABiophysicsMicroscopy Electron ScanningMolecular Medicineinulin magnetoplexes polycation siRNA SPIONsBiotechnologymagnetoplexesPharmaceutical research
researchProduct

MTA HP Repair stimulates in vitro an homogeneous calcium phosphate phase coating deposition

2019

Background To study the mineralization capacity in vitro of the bioceramic endodontic material MTA HP Repair. Material and methods Bioactivity evaluation in vitro was carried out, by soaking processed cement disk in simulated body fluid (SBF) during 168 h. The cement surface was studied by Fourier transform infrared spectroscopy (FT-IR), field emission gun scanning electron microscopy (FEG-SEM) and energy dispersive X-ray analysis (EDX). Release to the SBF media of ionic degradation products was monitored using inductively coupled plasma atomic emission spectroscopy (ICP-AES). Results FT-IR showed increasing formation of phosphate phase bands at 1097, 960, 607 and 570 cm-1 with prolonged SB…

CementMaterials scienceScanning electron microscopeResearchSimulated body fluid030206 dentistry02 engineering and technologyBioceramic:CIENCIAS MÉDICAS [UNESCO]021001 nanoscience & nanotechnologyPhosphateOperative Dentistry and Endodontics03 medical and health sciencesSurface coatingchemistry.chemical_compound0302 clinical medicinechemistryInductively coupled plasma atomic emission spectroscopyUNESCO::CIENCIAS MÉDICASFourier transform infrared spectroscopy0210 nano-technologyGeneral DentistryNuclear chemistryJournal of Clinical and Experimental Dentistry
researchProduct

Physicochemical parameters - hydration performance relationship of the new endodontic cement MTA Repair HP

2019

Background To characterize the chemical composition and textural parameters of the MTA Repair HP precursor powder and their influence to hydration performance. Material and methods Un-hydrated precursor material was characterized by X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR), X-ray fluorescence (XRF), laser diffraction (LD), N2 physisorption and field emission gun scanning electron microscopy (FEG-SEM). Setting time was assessed according to ASTM specification C 266. Hydrated material was analysed by XRD, FT-IR, energy dispersive X-ray (EDX) analysis and FEG-SEM. Results Ca3SiO5 and Ca2SiO4, in addition to CaWO4 as radiopacifier are the main compositional phase…

CementMaterials scienceScanning electron microscopeResearchchemistry.chemical_elementNanoparticle030206 dentistry02 engineering and technology:CIENCIAS MÉDICAS [UNESCO]021001 nanoscience & nanotechnologyOperative Dentistry and Endodontics03 medical and health sciences0302 clinical medicinechemistryPhysisorptionChemical engineeringAluminiumSpecific surface areaUNESCO::CIENCIAS MÉDICASFourier transform infrared spectroscopy0210 nano-technologyField emission gunGeneral DentistryJournal of Clinical and Experimental Dentistry
researchProduct

Mechanical performance of experimental acrylic resins modified by nanoparticles after chemical and mechanical degradation.

2020

Background Different materials have been incorporated into the polymethylmethacrylate matrix to improve its performance. The aim of this study was to evaluate the degree of conversion (DC), the flexural strength (FS), the elasticity modulus (EM), and the effect of exposure to food-simulating liquids prior to brushing simulation on the gloss loss (GL) of experimental acrylic resins modified by nanoparticles. Material and methods Three different types of nanoparticles; silicon oxide (SiO2), cerium oxide (CeO2) and titanium oxide (TiO2) were added to a poly (methylmethacrylate) matrix, in proportions of 0.5wt%, 1wt% and 3wt% each, forming nine experimental groups. The acrylic resin was also te…

Cerium oxideMaterials scienceResearch030206 dentistry02 engineering and technology021001 nanoscience & nanotechnologyGloss (optics)Titanium oxide03 medical and health sciences0302 clinical medicineFlexural strengthvisual_artBiomaterials and Bioengineering in Dentistryvisual_art.visual_art_mediumComposite materialFourier transform infrared spectroscopy0210 nano-technologySilicon oxideGeneral DentistryElastic modulusAcrylic resinUNESCO:CIENCIAS MÉDICASJournal of clinical and experimental dentistry
researchProduct

On the use of fractional calculus for the probabilistic characterization of random variables

2009

In this paper, the classical problem of the probabilistic characterization of a random variable is re-examined. A random variable is usually described by the probability density function (PDF) or by its Fourier transform, namely the characteristic function (CF). The CF can be further expressed by a Taylor series involving the moments of the random variable. However, in some circumstances, the moments do not exist and the Taylor expansion of the CF is useless. This happens for example in the case of $\alpha$--stable random variables. Here, the problem of representing the CF or the PDF of random variables (r.vs) is examined by introducing fractional calculus. Two very remarkable results are o…

Characteristic function (probability theory)FOS: Physical sciencesAerospace EngineeringMathematics - Statistics TheoryOcean EngineeringProbability density functionComplex order momentStatistics Theory (math.ST)Fractional calculusymbols.namesakeIngenieurwissenschaftenFOS: MathematicsTaylor seriesApplied mathematicsCharacteristic function serieMathematical PhysicsCivil and Structural EngineeringMathematicsGeneralized Taylor serieMechanical EngineeringStatistical and Nonlinear PhysicsProbability and statisticsMathematical Physics (math-ph)Condensed Matter PhysicsFractional calculusFourier transformNuclear Energy and EngineeringPhysics - Data Analysis Statistics and ProbabilitysymbolsFractional calculus; Generalized Taylor series; Complex order moments; Fractional moments; Characteristic function series; Probability density function seriesddc:620Series expansionFractional momentProbability density function seriesSettore ICAR/08 - Scienza Delle CostruzioniRandom variableData Analysis Statistics and Probability (physics.data-an)
researchProduct

Fourier transform spectroscopy and direct potential fit of a shelflike state: application to E(4)1Σ(+) KCs.

2011

The paper presents high-resolution experimental study and a direct potential construction of a shelflike state E(4)(1)Σ(+) of the KCs molecule converging to K(4(2)S) + Cs(5(2)D) atomic limit; such data are of interest for selecting optical paths for producing and monitoring cold polar diatomics. The collisionally enhanced laser induced fluorescence (LIF) spectra corresponding to both spin-allowed E(4)(1)Σ(+) → X(1)(1)Σ(+) and spin-forbidden E(4)(1)Σ(+) → a(1)(3)Σ(+) transitions of KCs were recorded in visible region by Fourier transform spectrometer with resolution of 0.03 cm(-1). Overall about 1650 rovibronic term values of the E(4)(1)Σ(+) state of (39)K(133)Cs and (41)K(133)Cs isotopologu…

Chebyshev polynomialsChemistryAnalytical chemistryGeneral Physics and AstronomyIsotopologuePhysical and Theoretical ChemistryAtomic physicsQuantum numberLaser-induced fluorescencePotential energyDiatomic moleculeSpectral lineFourier transform spectroscopyThe Journal of chemical physics
researchProduct

3D spectral imaging with synchrotron Fourier transform infrared spectro-microtomography

2013

We report Fourier transform infrared spectro-microtomography, a nondestructive three-dimensional imaging approach that reveals the distribution of distinctive chemical compositions throughout an intact biological or materials sample. The method combines mid-infrared absorption contrast with computed tomographic data acquisition and reconstruction to enhance chemical and morphological localization by determining a complete infrared spectrum for every voxel (millions of spectra determined per sample).

Chemical imagingmedicine.medical_specialtyMaterials scienceInfrared spectroscopyBiochemistryFourier transform spectroscopyPhysics::GeophysicsMicesymbols.namesakeImaging Three-DimensionalOpticsSpectroscopy Fourier Transform InfraredMicroscopyImage Processing Computer-AssistedmedicineAnimalsHumansFourier transform infrared spectroscopyMolecular BiologyEmbryonic Stem Cellsbusiness.industryX-Ray MicrotomographyCell BiologyWoodSpectral imagingPopulusFourier transformsymbolsbusinessChemical fingerprintingSynchrotronsHairBiotechnologyNature Methods
researchProduct

Internal ion impact ionization for Fourier-transform ion cyclotron resonance

1994

A general scheme for ionization and fragmentation of ions in Fourier-transform ion cyclotron resonance mass spectrometry (FT-ICRMS) is introduced. The technique is based upon excitation of high-frequency (i.e. lowmass) primary ions (e.g. N, Al+, H2O+·) which may be generated by standard ionization methods (e.g. electron ionization or laser desorption) inside the trap. Generation of the primary ions is followed by excitation of their cyclotron motion to high translational energy to serve as projectile ions. The projectiles serve two functions: to ionize neutral gas atoms and/or molecules (secondary ions) within the trap internal ion impact ionization (IIII), and to collisionally activate the…

Chemical ionizationChemistryOrganic ChemistryAnalytical chemistryThermal ionizationFourier transform ion cyclotron resonanceIon sourceAnalytical ChemistryAtmospheric-pressure laser ionizationPhysics::Plasma PhysicsIonizationAtomic physicsSpectroscopyElectron ionizationIon cyclotron resonanceRapid Communications in Mass Spectrometry
researchProduct

Making Broad Proteome Protein Measurements in 1−5 min Using High-Speed RPLC Separations and High-Accuracy Mass Measurements

2005

The throughput of proteomics measurements that provide broad protein coverage is limited by the quality and speed of both the separations as well as the subsequent mass spectrometric analysis; at present, analysis times can range anywhere from hours (high throughput) to days or longer (low throughput). We have explored the basis for proteomics analyses conducted on the order of minutes using high-speed capillary RPLC combined through on-line electrospray ionization interface with high-accuracy mass spectrometry (MS) measurements. Short 0.8-microm porous C18 particle-packed 50-microm-i.d. capillaries were used to speed the RPLC separations while still providing high-quality separations. Both…

Chemical ionizationElectrosprayTime FactorsChromatographyProteomeChemistryElutionElectrospray ionizationAnalytical chemistryMass spectrometryMass SpectrometryPeptide FragmentsFourier transform ion cyclotron resonanceFourier transform spectroscopyAnalytical ChemistrySpectroscopy Fourier Transform InfraredAnimalsHumansTrypsinHydrophobic and Hydrophilic InteractionsIon cyclotron resonanceChromatography LiquidAnalytical Chemistry
researchProduct

Fourier transform nmr investigations of organotin compounds

1980

Abstract NMR spectra have been obtained for fiteen title compounds, mainly with R = Me. Tin chemical shifts were found to lie within the expected ranges, but to vary little with R or, apparently, with change in ring size. While the magnitute of 1 (SnSe) was as predicted, the of 1 (SnTe) was more than twice as large as that previously observed for (Me 3 Sn) 2 Te. In compounds Me 6 Sn( 3 X 3 , 2 J(SnMSn) varied systematically with variations in x, but within relatively narrow limits (195-250 Hz); a much more drastic variation was observed for Me 6 Sn 3 X 2 , possibly due to bond angle changes at Sn and X.

Chemical shiftOrganic ChemistryAnalytical chemistrychemistry.chemical_elementBiochemistryInorganic ChemistryRing sizeNMR spectra databasesymbols.namesakeMolecular geometryFourier transformchemistryMaterials ChemistrysymbolsPhysical and Theoretical ChemistryTinJournal of Organometallic Chemistry
researchProduct