Search results for "frequency analysi"

showing 10 items of 116 documents

Rotational coherence imaging and control for CN molecules through time-frequency resolved coherent anti-Stokes Raman scattering

2011

Numerical wave packet simulations are performed for studying coherent anti-Stokes Raman scattering (CARS) for CN radicals. Electronic coherence is created by femtosecond laser pulses between the X²Σ and B²Σ states. Due to the large energy separation of vibrational states, the wave packets are superpositions of rotational states only. This allows for a specially detailed inspection of the second- and third-order coherences by a two-dimensional imaging approach. We present the time-frequency domain images to illustrate the intra- and intermolecular interferences, and discuss the procedure to rationally control and experimentally detect the interferograms in solid Xe environment. peerReviewed

Wave packetvibraatiotilatGeneral Physics and Astronomyrotaatiotilatvapaat radikaalit01 natural sciencesMolecular physicslaw.inventionsymbols.namesakeNuclear magnetic resonancecoherent antiStokes Raman scatteringlaw0103 physical sciencesCoherent anti-Stokes Raman spectroscopyPhysical and Theoretical Chemistry010306 general physicsta116010304 chemical physicsta114rotationla statesChemistryIntermolecular forcekoherentti anti-Stokes Raman spektroskopiaLaserTime–frequency analysisFemtosecondsymbolshiiliyhdisteetcarbon comboundsnumeerinen analyysivibrational statesRaman scatteringCoherence (physics)The Journal of Chemical Physics
researchProduct

Time-Frequency behaviour of the a-wave of the human electroretinogram

2007

The electroretinogram is the record of the electrical response of the retina to a light stimulus. The two main components are the a-wave and the b-wave, the former is related to the early photoreceptoral activity. Aim of this paper is to acquire useful information about the time-frequency features of the human a-wave, by means of the wavelet analysis. This represents a proper approach in dealing with nonstationary signals. We have used the Mexican Hat as mother wavelet. The analysis, carried out for four representative values of the luminance, comprehends the frequency dependence of the variance and the skeleton. The results indicate a predominance of low frequency components, their time di…

Waveletbusiness.industryTime distributionPattern recognitionArtificial intelligenceFrequency dependenceStimulus (physiology)Low frequencybusinessLuminanceContinuous wavelet transformMathematicsTime–frequency analysis
researchProduct

Design and Implementation of Acoustic Source Localization on a Low-Cost IoT Edge Platform

2020

The implementation of algorithms for acoustic source localization on edge platforms for the Internet of Things (IoT) is gaining momentum. Applications based on acoustic monitoring can greatly benefit from efficient implementations of such algorithms, enabling novel services for smart homes and buildings or ambient-assisted living. In this context, this brief proposes extreme low-cost sound source localization system composed of two microphones and the low power microcontroller module ESP32. A Direction-Of-Arrival (DOA) algorithm has been implemented taking into account the specific features of this board, showing excellent performance despite the memory constraints imposed by the platform. …

business.industryMicrophoneComputer scienceEmbedded systemsProcess (computing)Esp32Context (language use)Acoustic source localizationIngeniería IndustrialTime–frequency analysisSound source localizationMicrocontrollerDoa estimationEnhanced Data Rates for GSM EvolutionElectrical and Electronic EngineeringbusinessImplementationComputer hardware
researchProduct

Sensitivity and Specificity of Stability Criteria for Immediately Loaded Splinted Maxillary Implants

2014

Background To assess the suitability of dental implants for immediate loading, primary stability is usually evaluated intraoperatively. Purpose This retrospective study aimed to assess the suitability of three stability parameters – namely, insertion torque (IT), implant stability quotient (ISQ; measured by resonance frequency analysis), and Periotest (PT) values – as potential predictors for the risk of nonosseointegration of immediately loaded splinted implants. The stability parameters were routinely collected under immediate loading. Materials and Methods Nineteen patients with 11 edentulous and 8 partially edentulous maxillae were treated with 105 dental implants, which were immediatel…

business.industrymedicine.medical_treatmentArea under the curveDentistryAnatomyImplant stability quotientOsseointegrationResonance frequency analysisMaxillaImmediate loadingmedicineImplantOral SurgeryDenturesbusinessGeneral DentistryClinical Implant Dentistry and Related Research
researchProduct

Updated secondary implant stability data of two dental implant systems. A retrospective cohort study

2017

Background At present, updated secondary implant stability data generated by actual versions of resonance frequency analysis (RFA) and mobility measurement (MM) electronic devices of 2 different implant systems with actual manufactured surfaces seem to lack and/or are incomplete. Material and Methods Secondary implant stability data based on both RFA and MM measurements were collected and analyzed from 44 formerly treated patients (24 f, 20 m) that received either Ankylos Cellplus (Ø3.5mm) (A) (n=36) or Straumann regular neck SLA tissue level (Ø4.1mm) (S) (n=37) implants in posterior positions of both jawbones (total number= 72). These results were interpretated in view of formerly publishe…

business.industrymedicine.medical_treatmentResearchTissue levelDentistryRetrospective cohort study:CIENCIAS MÉDICAS [UNESCO]First generationResonance frequency analysisUNESCO::CIENCIAS MÉDICASMedicinePeriodontologyImplantbusinessDental implantGeneral DentistryJournal of Clinical and Experimental Dentistry
researchProduct

Evaluation of the primary stability in dental implants placed in low density bone with a new drilling technique, osseodensification: an in vitro study

2020

Background Primary stability is an important key determinant of implant osseointegration. We investigated approaches to improve primary implant stability using a new drilling technique termed osseodensification (OD), which was compared with the conventional under-drilling (UD) method utilized for low-density bones. Material and Methods We placed 55 conical internal connection implants in each group, in 30 low-density sections of pig tibia. The implants were placed using twist drill bits in both groups; groups Under Drilling (UD) and Osseodensification (OD) included bone sections subjected to conventional UD and OD drilling, respectively. Before placing the implants, we randomized the bone s…

computer-assisted diagnosisMaterials scienceSwinecomputer-assisted image processingOsseointegrationDental Prosthesis Retentionradicular cysts03 medical and health sciences0302 clinical medicineBone DensityOsseointegrationLow densityAnimalscomputer-assisted image analysisIn vitro studyTibiaGeneral DentistryUNESCO:CIENCIAS MÉDICASInternal connectionDental ImplantsResearchTwist drillDental Implantation EndosseousResonance Frequency Analysis030206 dentistryResonance frequency analysisTorqueOtorhinolaryngologykeratocystsodontogenic cystsSurgeryImplantImplantologyBiomedical engineering
researchProduct

Time-Frequency Characteristics of In-Home Radio Channels Influenced by Activities of the Home Occupant

2019

While aging is a serious global concern, in-home healthcare monitoring solutions are limited to context-aware systems and wearable sensors, which may easily be forgotten or ignored for privacy and comfort reasons. An emerging non-wearable fall detection approach is based on processing radio waves reflected off the body, who has no active interaction with the system. This paper reports on an indoor radio channel measurement campaign at 5.9 GHz, which has been conducted to study the impact of fall incidents and some daily life activities on the temporal and spectral properties of the indoor channel under both line-of-sight (LOS) and obstructed-LOS (OLOS) propagation conditions. The time-frequ…

device-free fall detectionComputer scienceReal-time computingWearable computerVDP::Information and communication science: 42002 engineering and technologylcsh:Chemical technology01 natural sciencesBiochemistryArticleAnalytical ChemistryDoppler power spectral density0202 electrical engineering electronic engineering information engineeringlcsh:TP1-1185Electrical and Electronic EngineeringInstrumentationnon-stationary radio channels010401 analytical chemistry020206 networking & telecommunicationsAtomic and Molecular Physics and Optics0104 chemical sciencesTime–frequency analysisspectrogram analysisVDP::Informasjons- og kommunikasjonsvitenskap: 420Radio waveCommunication channelambient-assisted livingSensors (Basel, Switzerland)
researchProduct

Quantitative Rotor Broken Bar Evaluation in Double Squirrel Cage Induction Machines under Dynamic Operating Conditions

2013

Advanced monitoring techniques leading to fault diagnosis and prediction of induction machine faults, operating under non-stationary conditions have gained strength because of its considerable influence on the operational continuation of many industrial processes. In case of rotor broken bars, fault detection based on sideband components issued from currents, flux, instantaneous control or power signals under different load conditions, may fail due to the presence of inter-bar currents that reduce the degree of rotor asymmetry, especially for double squirrel cage induction motors. But the produced core vibrations in the axial direction, can be investigated to overcome the limitation of the …

discrete wavelet transformEngineeringbusiness.industryRotor (electric)Squirrel-cage rotorBar (music)squirrel cage motorSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciFault (power engineering)FAULT DIAGNOSISFault detection and isolationPower (physics)law.inventionVibrationTime-Frequency AnalysisControl theorylawAC Machine Condition monitoring Double cage rotor fault diagnostics induction motor wavelet TransformbusinessInduction motor
researchProduct

Is clinical experience important for obtaining the primary stability of dental implants with aggressive threads? An ex vivo study

2018

GECKILI, ONUR/0000-0002-7852-3915; dayan, suleyman cagatay/0000-0003-3081-9618; Bilhan, Hakan/0000-0003-1787-3003 WOS:000460131200015 PubMed ID: 30818319 Background: The aim of this study was to investigate the clinicians' experience on maintaining the primary stability of implants with aggressive threads belonging to a novel dental implant system. Material and Methods: Three hundred implants with aggressive threads were inserted in fresh bovine ribs mimicking Type IV bone by five clinicians which were classified according to their previous experience of total number of implant insertion. An independent examiner measured the primary stability of all implants after insertion by using resonan…

experimental designmedicine.medical_treatmentDentistryIn Vitro TechniquesOsseointegration03 medical and health sciences0302 clinical medicineOsseointegrationmedicineDental Prosthesis DesignAnimalsDental implantGeneral DentistryDental Implantsbusiness.industryResearchDental Implantation EndosseousDental Modelsosseointegration030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Models DentalBiomechanical PhenomenaResonance frequency analysisDental Implant-Abutment DesignOtorhinolaryngologyDental Prosthesis DesignTorqueResearch DesignUNESCO::CIENCIAS MÉDICASSurgeryCattleImplantOral SurgerybusinessImplantologyEx vivo
researchProduct

Stochastic response of fractional visco-elastic beams

2012

fractional calculus stochastic analysis beamViscoelasticity Fractional Calculus Fractional Kelvin-Voigt model Euler- Bernoulli beam Eigenfunction Frequency analysis
researchProduct