Search results for "gas chromatography-mass spectrometry"

showing 10 items of 318 documents

Determination of hydroxylated benzophenone UV filters in sea water samples by dispersive liquid-liquid microextraction followed by gas chromatography…

2010

A new analytical method for the determination of four hydroxylated benzophenone UV filters (i.e. 2-hydroxy-4-methoxybenzophenone (HMB), 2,4-dihydroxybenzophenone (DHB), 2,2'-dihydroxy-4-methoxybenzophenone (DHMB) and 2,3,4-trihydroxybenzophenone (THB)) in sea water samples is presented. The method is based on dispersive liquid-liquid microextraction (DLLME) followed by gas chromatography-mass spectrometry (GC-MS) determination. The variables involved in the DLLME process were studied. Under optimized conditions, 1000 microL of acetone (disperser solvent) containing 60 microL of chloroform (extraction solvent) were injected into 5 mL of aqueous sample adjusted to pH 4 and containing 10% NaCl…

Detection limitChromatographySilylationOrganic ChemistryGeneral MedicineBSTFAChemical FractionationBiochemistryGas Chromatography-Mass SpectrometryAnalytical Chemistrychemistry.chemical_compoundBenzophenoneschemistryStandard additionSample preparationSeawaterGas chromatographyGas chromatography–mass spectrometryDerivatizationWater Pollutants ChemicalJournal of chromatography. A
researchProduct

Implementing the contamination prevention programs in the pesticide industry by infrared spectroscopy.

2014

Abstract An infrared spectroscopy based methodology has been successfully developed to implement contamination prevention programs in the pesticide industry. Sensitivity of the IR procedure, traditionally considered the Achilles Hell of the technique, has been improved by using a transmission cell with an open upper side, an internal volume of 35 µL and an optical pathlength of 0.5 mm, providing detection limits of 32 mg L−1 for folpet and 48 mg L−1 for cymoxanil. The manufacturing of folpet and cymoxanil was employed as an example and the IR methodology was validated for the implementation of contamination prevention programs in the pesticide industry. The swab test and rinsate method were…

Detection limitChromatographySpectrophotometry InfraredChemistryChlorpyrifos-methylAnalytical chemistryInfrared spectroscopyContaminationPesticideOptical pathlengthGas Chromatography-Mass SpectrometryAnalytical ChemistryLimit of DetectionChemical IndustryEnvironmental PollutantsPesticidesTalanta
researchProduct

Comparison of different methods for extraction of polycyclic aromatic hydrocarbons (PAHs) from Sicilian (Italy) coastal area sediments.

2012

This paper describes a work aimed at improving the conditions of an extraction method, coupling GC-MS determination, for the analysis without cleanup phase, of polycyclic aromatic hydrocarbons (PAHs) from sediment samples. The automatic Soxhlet extraction in warm mode (using Extraction System B-811 Standard, Buchi) has demonstrated advantages for automation, reduced extraction time, and lower solvent use than for conventional Soxhlet extraction. Under these conditions, the recoveries are very good as they resulted greater than 85 % and, in most of the cases, near 100 %. The repeatability is also satisfactory (relative standard deviation less than 15 %). The detection limits are also accepta…

Detection limitGeologic SedimentsExtraction (chemistry)SedimentGeneral MedicineRepeatabilityChemical FractionationManagement Monitoring Policy and LawPollutionGas Chromatography-Mass SpectrometrySettore CHIM/12 - Chimica Dell'Ambiente E Dei Beni CulturaliMatrix (chemical analysis)Dry weightEnvironmental chemistryEnvironmental scienceEcotoxicologySeawaterSettore CHIM/01 - Chimica AnaliticaPolycyclic Aromatic HydrocarbonsGas chromatography–mass spectrometryAutomatic extraction .CRM . PAHs . Sediments . GC-MSSicilyWater Pollutants ChemicalEnvironmental MonitoringGeneral Environmental Science
researchProduct

Validated, non-destructive and environmentally friendly determination of cocaine in euro bank notes.

2005

A non-destructive, fast and environmentally friendly procedure has been developed for cocaine determination in euro bank notes. Cocaine was extracted with 15 ml methanol by vortex agitation during 5 min. The extract was evaporated and reconstituted in 0.5 ml methanol. GC-MS-MS analysis was performed using as precursor ion m/z 182.2, with an excitation energy voltage of 1.60 eV, being the product ions measured m/z 150.2 and 82.0. A limit of detection of 0.15 ng per note and a repeatability of 6%, established from the relative standard deviation, of a 1 ng ml(-1) level, were achieved. Recoveries of 101+/-2 and 98+/-3% were obtained for samples spiked with 100 and 10 microg respectively. Resul…

Detection limitPaperChromatographyOrganic ChemistryForensic SciencesAnalytical chemistryReproducibility of ResultsGeneral MedicineRepeatabilityBiochemistryEnvironmentally friendlySensitivity and SpecificityGas Chromatography-Mass SpectrometryAnalytical Chemistrychemistry.chemical_compoundchemistryCocaineSample preparationMethanolGas chromatographyGas chromatography–mass spectrometryQuantitative analysis (chemistry)Journal of chromatography. A
researchProduct

Green, rapid and simultaneous determination of ‘alternative preservatives’ in cosmetic formulations by gas chromatography-mass spectrometry

2022

Abstract Some hydroxylated compounds commonly used in cosmetic formulations including short chain glycols, benzylic alcohols, and organic acids show antimicrobial activity, although they are not considered as preservatives according to the existing European legislation. These ‘alternative preservatives’ are not exempt of potential side-effects for cosmetics users. The aim of this work is to develop a simple and affordable analytical method useful for the simultaneous and green determination of fourteen compounds used as ‘alternative preservatives’ in cosmetic samples with different matrices. The proposed method allows a rapid sample preparation by simple dissolution or dispersion of the sam…

Detection limitPreservativeChromatographyChemistrymedia_common.quotation_subjectPreservatives PharmaceuticalClinical BiochemistryPharmaceutical ScienceCosmeticsMass spectrometryCosmeticsGas Chromatography-Mass SpectrometryAnalytical ChemistryDrug DiscoverySample preparationGas chromatographyGas chromatography–mass spectrometryCosmetic industrySpectroscopymedia_commonJournal of Pharmaceutical and Biomedical Analysis
researchProduct

Determination of the new psychoactive substance dichloropane in saliva by microextraction by packed sorbent – Ion mobility spectrometry

2018

Abstract A simple procedure based on microextraction by packed sorbent (MEPS) has been proposed for the extraction of dichloropane in oral fluids and its determination by ion mobility spectrometry (IMS). Extraction conditions such as type of sorbent (octyl and octadecyl silica), sample pH, number of sample loadings, and elution volume were evaluated to obtain the most appropriate values. Dichloropane was extracted from saliva samples using C8 MEPS, loading with 100 μL sample (adjusted to pH 7) in 4 cycles, washing with 100 μL deionized water, and eluting with 50 μL 2-propanol in 10 cycles. The proposed MEPS procedure has been validated in terms of linearity, accuracy, and precision. A limit…

Detection limitSalivaSorbentChromatographyChemistryIon-mobility spectrometryElution010401 analytical chemistryOrganic ChemistryExtraction (chemistry)General Medicine010402 general chemistryMass spectrometry01 natural sciencesBiochemistryGas Chromatography-Mass Spectrometry0104 chemical sciencesAnalytical ChemistryCocaineLimit of DetectionIon Mobility SpectrometryHumansGas chromatography–mass spectrometrySalivaSolid Phase MicroextractionJournal of Chromatography A
researchProduct

Evaluation of solid-phase extraction and stir-bar sorptive extraction for the determination of fungicide residues at low-microg kg(-1) levels in grap…

2004

Abstract A liquid chromatography–mass spectrometry method has been developed for determining bitertanol, carboxin, flutriafol, pyrimethanil, tebuconazole and triadimefon. The evaluation of both atmospheric pressure interfaces (API), atmospheric pressure chemical ionization (APCI) and electrospray (ESI) using positive and negative ionization modes, clearly shows that the studied pesticides are more sensitive using APCI in positive mode. Two procedures based on solid-phase extraction (SPE) and stir-bar sorptive extraction (SBSE) have been assessed for extracting these compounds in grape. The recoveries obtained by SPE in samples spiked at the limit of quantification (LOQ) level ranged from 60…

Detection limitSpectrometry Mass Electrospray IonizationChromatographyChemistryOrganic ChemistryExtraction (chemistry)Pesticide ResiduesReproducibility of ResultsAtmospheric-pressure chemical ionizationGeneral MedicineHydrogen-Ion ConcentrationMass spectrometryBiochemistryHigh-performance liquid chromatographyGas Chromatography-Mass SpectrometryAnalytical ChemistryFungicides Industrialchemistry.chemical_compoundLiquid chromatography–mass spectrometryPyrimethanilVitisSolid phase extractionAdsorptionMicrowavesChromatography High Pressure LiquidJournal of chromatography. A
researchProduct

Fast extraction of cannabinoids in marijuana samples by using hard-cap espresso machines

2018

Abstract A simple, quick and low cost procedure was developed for the extraction of Δ9-tetrahydrocannabinol, cannabidiol, and cannabinol from marijuana samples, based on the use of a hard-cap espresso extraction with 2-propanol. After extraction, cannabinoids were directly determined after appropriate dilution by gas-chromatography-mass spectrometry, reaching a limit of detection from 0.03 to 0.05 mg g−1. Extraction efficiency was evaluated by the comparison of results obtained for seized samples by the proposed method and a reference methodology based on ultrasound-assisted extraction. Moreover, ion mobility was proposed for the rapid and sensitive determination of Δ9-tetrahydrocannabinol …

Detection limitTime FactorsChromatographyCannabinoidsIon-mobility spectrometry010401 analytical chemistryExtraction (chemistry)Chemical FractionationCoffee01 natural sciencesGas Chromatography-Mass Spectrometry0104 chemical sciencesAnalytical Chemistry03 medical and health scienceschemistry.chemical_compoundEspresso0302 clinical medicinechemistryδ 9 tetrahydrocannabinolCannabinolHumans030216 legal & forensic medicineGas chromatography–mass spectrometryCannabisTalanta
researchProduct

Determination of volatile organic compounds in contaminated air using semipermeable membrane devices

2009

Abstract Semipermeable membrane devices (SPMDs) were evaluated as passive samplers for the determination of 26 volatile organic compounds (VOCs) in contaminated air of occupational environments. A direct methodology based on the use of head-space-gas chromatography–mass spectrometry (HS-GC–MS) was developed for VOCs determinations in SPMDs, without any sample pre-treatment and avoiding the use of solvents. A desorption temperature of 150 °C for 10 min was sufficient for a sensitive VOCs determination providing limits of detection in the range of 15 ng SPMD−1 for 21 of 26 studied compounds. Linear and equilibrium uptake models were established for each VOC from compound isotherms. Highly vol…

Detection limitchemistry.chemical_classificationAir PollutantsVolatile Organic CompoundsChromatographyAir pollutionMembranes Artificialmedicine.disease_causeMass spectrometryGas Chromatography-Mass SpectrometryAnalytical ChemistrySolventchemistryLimit of DetectionDesorptionEnvironmental chemistrymedicineVolatile organic compoundGas chromatographySemipermeable membraneEnvironmental MonitoringTalanta
researchProduct

Synthesis and gas chromatographic-mass spectrometric analysis of reduced compounds derived from 6 alpha- and 6 beta-hydroxy-11-deoxycorticosterone.

1989

Abstract A series of thirty two 6-hydroxylated steroids were synthesized by selective reduction of the 4–5 double bond, the 3-oxo group, and/or the 20-oxo group of 6α- and 6β-hydroxyDOC. The different reactions leading to the production of specific isomers are discussed. The gas chromatographic and spectrometric characteristics of the methoxime-trimethylsilyl (MO-TMS) or trimethylsilyl (TMS) derivatives of the isomers obtained are given. The gas chromatographic separation of the syn- and anti -isomers of the methoxime in position 3 was found to be characteristic of the configuration of the hydroxyl in position 6. The difference between methylene unit values of syn- and anti- isomers is much…

Double bondTrimethylsilylChemical PhenomenaClinical BiochemistrySubstituentMass spectrometryBiochemistryChemical synthesisGas Chromatography-Mass Spectrometrychemistry.chemical_compoundEndocrinologyOrganic chemistrySelective reductionMethyleneDesoxycorticosteroneMolecular BiologyPharmacologychemistry.chemical_classificationChromatographyOrganic ChemistryStereoisomerismChemistrychemistrySteroidsGas chromatographyOxidation-ReductionSteroids
researchProduct