A novel approach to current transformer characterization in the presence of harmonic distortion

2009

The current transformer (CT) performance under distorted waveform conditions is usually characterized by means of the frequency-response test. In this paper, a new way to characterize CTs, closer to real operation conditions, is proposed. The harmonic phase-angle and ratio errors are measured using a nonsinusoidal current composed of fundamental and one harmonic with adjustable phase shift. The new method was tested by determining the performance of two metering class CTs commonly used by the Italian power company. The errors measured using the proposed approach are larger than the ones obtained with the frequency response. This result suggests that the frequency-response approach for the e…

EngineeringFrequency responseElectric current measurementAcousticsElectric transformer testingErrorsElectric utilitiesOperation conditionsHarmonic distortionPower companiesHarmonic analysisElectric power transmission networksFrequency responsePower electronicsWaveformMetering modeCurrent transformer (CT)Electrical and Electronic EngineeringInstrumentationNon-sinusoidal currentsPiezoelectric transducersTotal harmonic distortionbusiness.industryElectric power distributioncurrent transformer frequency response harmonic distortion power system harmonics transducersCurrent transformerRatio errorsTransducerElectric instrument transformersHarmonicPower system harmonicsCurrent (fluid)businessPower transmissionSettore ING-INF/07 - Misure Elettriche E ElettronicheDistorted waveforms
researchProduct

2D harmonic analysis of the cogging torque in synchronous permanent magnet machines

2004

Presents an approach to determine sources of cogging torque harmonics in permanent magnet electrical machines on the basis of variations of air‐gap magnetic flux density with time and space. The magnetic flux density is determined from the two‐dimensional (2D) finite element model and decomposed into the double Fourier series through the 2D fast Fourier transform (FFT). The real trigonometric form of the Fourier series is used for the purpose to identify those space and time harmonics of magnetic flux density whose involvement in the cogging torque is the greatest relative contribution. Carries out calculations for a symmetric permanent magnet brushless machine for several rotor eccentricit…

EngineeringRotor (electric)business.industryApplied MathematicsFast Fourier transformMathematical analysisCogging torqueComputer Science Applicationslaw.inventionMagnetic fieldHarmonic analysisComputational Theory and MathematicslawHarmonicsMagnetElectronic engineeringElectrical and Electronic EngineeringbusinessFourier seriesCOMPEL - The international journal for computation and mathematics in electrical and electronic engineering
researchProduct

An induction motor speed measurement method based on current harmonic analysis with the Chirp-Z Transform

2005

This paper presents a new method to measure motor speed by means of frequency estimation of rotor slot spectral components in the supply current of squirrel single-cage induction motors. The novelty of the method consists in the harmonic analysis of the supply current by means of the chirp-Z transform (CZT). The advantages are improved accuracy due to better spectral resolution and resolvability. Moreover, a shorter observation window is required, thus reducing errors related to nonstationary current signals. The experimental results are presented to validate the proposed method and to make a comparison with a similar method based on the fast Fourier transform (FFT).

EngineeringRotor (electric)business.industryBluestein's FFT algorithmFast Fourier transformMotorsMeasure (mathematics)law.inventionHarmonic analysisefficiency estimationInduction motorslawElectronic engineeringElectrical and Electronic EngineeringSpectral resolutionCurrent (fluid)businessInstrumentationInduction motor
researchProduct

An induction motor speed measurement based on current harmonic analysis with Chirp-Z Transform

2002

The paper presents a new method to measure motor speed by means of frequency estimation of rotor slot harmonics present in the supply current of squirrel single cage induction motors. The novelty of the method is the use of Chirp-Z Transform as supply current harmonic analysis. The advantages are an improved spectral resolution and accuracy. Moreover a shorter sampling time window is required reducing errors related to not stationary current signal. Experimental results are presented to validate the proposed method and to perform a comparison with FFT based one.

EngineeringRotor (electric)business.industryBluestein's FFT algorithmFast Fourier transformSignallaw.inventionHarmonic analysislawHarmonicsChirpElectronic engineeringbusinessInduction motorIMTC 2001. Proceedings of the 18th IEEE Instrumentation and Measurement Technology Conference. Rediscovering Measurement in the Age of Informatics (Cat. No.01CH 37188)
researchProduct

Disturbing Load Detection in Three-Wire and Four-Wire Systems Based on Novel Nonactive Powers From IEEE 1459-2000

2010

This paper presents an enhanced approach for the detection of disturbing loads in distorted and/or unbalanced three-phase power systems, both three-wire and four-wire. It is based on the IEEE Std. 1459-2000 effective apparent power resolution, and it requires only the separation of the fundamental components of voltage and current from the remaining harmonic content. In this paper, the formulation of the novel approach is given, and its effectiveness is discussed by means of several simulation tests, which were carried out on a simple test system.

EngineeringTotal harmonic distortionSIMPLE (military communications protocol)business.industryPower system harmonicsElectrical engineeringAC powerharmonic distortion harmonic sources power quality power measurement power system harmonic power system measurementHarmonic analysisElectric power systemHarmonicElectronic engineeringElectrical and Electronic EngineeringbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheInstrumentationVoltageIEEE Transactions on Instrumentation and Measurement
researchProduct

Arc Fault Detection Method Based on CZT Low-Frequency Harmonic Current Analysis

2017

This paper presents a method for the detection of series arc faults in electrical circuits, which has been developed starting from an experimental characterization of the arc fault phenomenon and an arcing current study in several test conditions. Starting from this, the authors have found that is it possible to suitably detect arc faults by means of a high-resolution low-frequency harmonic analysis of current signal, based on chirp zeta transform, and a proper set of indicators. The proposed method effectiveness is shown by means of experimental tests, which were carried in both arcing and nonarcing conditions and in the presence of different loads, chosen according to the UL 1699 standard…

Engineeringarc fault detection020209 energyseries arcsArc-fault circuit interrupter02 engineering and technologyUL 1699Fault detection and isolationlaw.inventionHarmonic analysisElectric arcarc fault circuit interrupter (AFCI)Arc dischargeslawArc discharges arc fault circuit interrupter (AFCI) arc fault detection electrical safety fault diagnosis home protection interrupters power system harmonics power system measurements series arcs UL 1699Fault current limiterhome protection0202 electrical engineering electronic engineering information engineeringElectronic engineeringElectrical and Electronic EngineeringInstrumentationpower system harmonicsinterruptersbusiness.industry020208 electrical & electronic engineeringfault diagnosispower system measurementsFault indicatorElectrical networkHarmonicelectrical safetybusinessSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Harmonic mitigation of a grid-connected photovoltaic system using shunt active filter

2017

Conventional LC filters cannot compensate effectively harmonics due to non-linear loads in a grid-connected photovoltaic (PV) system. Thus, active power filters (APF) are introduced due to its characteristics and performances, for compensation of harmonics from non-linear loads in the grid-connected photovoltaic (PV) system. This work presents a three-phase voltage-fed shunt active power filter implementation to mitigate the harmonics in which the filter control system focuses on generating reference source current for compensating harmonic effects from non-linear loads. Furthermore, the developed model is verified with an experimental data from a nonlinear load.

Engineeringbusiness.industry020209 energy020208 electrical & electronic engineeringPhotovoltaic system02 engineering and technologyAC powerHarmonic analysisControl theoryFilter (video)Harmonics0202 electrical engineering electronic engineering information engineeringGrid-connected photovoltaic power systemHarmonicElectronic engineeringbusinessActive filter2017 20th International Conference on Electrical Machines and Systems (ICEMS)
researchProduct

Implementation and experimental validation of a real-time PWM algorithm based on B-Spline carriers for three phase voltage source inverters

2009

This paper presents the implementation and experimental results of an algebraic real-time sinusoidal pulse width modulation algorithm (SPWM) based on B-Spline carriers. B-spline functions are used as carrier signals with the aim to to reduce harmonic content of the three phase inverter output voltage. The presented algorithm eliminates the problem of B-spline recursive evaluation with convolution integrals or convolution sums in digital counterpart. The pulse pattern synthesis is made with the help pre-calculated duty cycle expressions. In this way there is no real need to synthesize the carrier signal so the hardware and the whole inverter control system becomes cheaper, more reliable and …

Engineeringbusiness.industryPower factorSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciHarmonic analysisAmplitude modulationThree-phaseControl theoryDuty cycleElectronic engineeringInverterVoltage sourcebusinessAlgorithmPWM INVERTORS POWER CONVERTER HARMONICS SPLINESPulse-width modulation2009 IEEE International Symposium on Industrial Electronics
researchProduct

Finite-element performance comparison of IPMSMs with unsymmetrical double-layer windings

2017

This paper presents a comparison of the performances between IPMSMs (Interior Permanent Magnet Synchronous Machine) with a symmetrical and with two different types of unsymmetrical windings. The aim is to demonstrate that the adoption of slightly unsymmetrical windings does not significantly affect the performances of the machines, both in terms of cogging torque and torque/load angle characteristics, providing also the advantage of a higher possibility of choice in terms of slot number/poles ratio. More in particular, an IPMSM model (named IPMSM-1) derived from a commercial geometry equipped with a symmetrical winding is analyzed by using a Finite Element Method (FEM) approach. The simulat…

Engineeringunsymmetrical windingsStatorCogging torque; FEM analysis; IPMSM; permanent magnets; unsymmetrical windings; Renewable Energy Sustainability and the Environment; Automotive Engineering; Electrical and Electronic EngineeringFEM analysisSettore ING-IND/32 - Convertitori Macchine E Azionamenti Elettrici01 natural scienceslaw.inventionHarmonic analysislaw0103 physical sciencesTorqueRenewable EnergyElectrical and Electronic Engineering010306 general physicsFEM analysi010302 applied physicsSustainability and the EnvironmentRotor (electric)business.industryRenewable Energy Sustainability and the EnvironmentElectrical engineeringCogging torquepermanent magnetsStructural engineeringCogging torqueFinite element methodIPMSMSettore ING-IND/31 - ElettrotecnicaElectromagnetic coilMagnetAutomotive Engineeringpermanent magnetunsymmetrical windingbusiness
researchProduct

Improvement of Hall Effect Current Transducer Metrological Performances in the Presence of Harmonic Distortion

2010

The performance of Hall effect current transducers (HECTs), under distorted waveform conditions, is usually characterized by means of a frequency response test. In this paper, it was investigated if frequency response is able to correctly evaluate the ratio and the phase errors under distorted conditions. Two HECTs, with the accuracy class level of 1% and 0.5%, respectively, were experimentally characterized under two conditions: 1) sinusoidal excitation with frequencies ranging from 50 to 750 Hz, which is the well-known frequency response test, and 2) nonsinusoidal excitation using fundamental frequency and one harmonic with adjusted amplitude and phase shift. It was found that ratio and p…

Frequency responseElectric current measurementCurrent measurement current transducer frequency response hall effect devices harmonic distortion power system harmonics.AcousticsTransducersPhase (waves)GyratorsNon-sinusoidal excitationHarmonic distortionAccuracy levelFundamental frequenciesHarmonic analysisPhase errorElectric currentsError compensationFrequency responseFrequency response testsWaveformSinusoidal excitationsPhase shiftElectrical and Electronic EngineeringInstrumentationPhysicsTotal harmonic distortionElectric power distributionHall effectCurrent measurementsMetrological performanceCurrent transducerFundamental frequencyLight measurementAmplitudeAccuracy classHarmonicsMagnetic field effectsHarmonicHarmonic amplitudeSettore ING-INF/07 - Misure Elettriche E ElettronicheDistorted waveformsHarmonic componentsHall effect devicesIEEE Transactions on Instrumentation and Measurement
researchProduct