Search results for "high-performance liquid chromatography"
showing 10 items of 629 documents
High-Performance Liquid Chromatography/Electrospray Ionization Tandem Mass Spectrometry (HPLC-ESI-MSn) Analysis and Bioactivity Useful for Prevention…
2019
This study aimed at evaluating and comparing the chemical profile obtained by HPLC-ESI-MSn analysis, the inhibitory activity of enzymes linked to obesity (α-amylase, α-glucosidase, and lipase) and the antioxidant properties (DPPH, ABTS, FRAP, and β-carotene bleaching tests) of ethanol extracts of bulbs (BE) and aerial parts (APE) from Allium commutatum Guss. (known in Italy as “aglio delle isole”). The chemical profile revealed alliin as the main abundant compound with values of 31.5 and 38.8 mg/g extract for BE and APE, respectively. APE is rich also in quercetin (38.5 mg/g extract) and luteolin (31.8 mg/g extract). Bulbs extract exhibited the highest activity as inhibitor of enzymes linke…
Identification of Novel Phosphopeptides After Simulated Digestion of αs2-casein by Tandem Mass Spectrometry
2006
Casein phosphopeptides (CPPs) are encrypted in αs1-, αs2-and β-casein (CN) and can be released by in vitro, in vivohydrolysis or food processing of dairy foods. Bovine αs2-CN contains two cluster sequences of anionic phosphoseryl and glutamyl residues SpSpSpEE in its structure (residues 8–12 and 56–63), which can modulate mineral bioavailability. In this study αs2-casein (αs2-CN) was subjected to simulated gastrointestinal digestion. CPPs released were sequenced by on-line reversed-phase high performance liquid chromatography coupled to electrospray ionisation tandem mass spectrometry (RP-HPLC-ESIMS/MS). Six novel αs2-CN derived CPPs, Three of them (αs2-CN(54–87)4P,αs2-CN(24–70)4P and αs2-…
A useful procedure for detection of polyamines in biological samples as a potential diagnostic tool in cancer diagnosis
2017
Abstract Background Polyamines present in human body are frequently considered as markers of occurrence of cancer. Therefore, the availability of simple and efficient method for determination of their level in body liquids and tissues is of some interest. Methods Supported liquid membrane technology coupled with HPLC seems to be an appropriate technique to follow the level of polyamines in human blood and urine. Thus, the membranes of two different geometries: flat sheet and hollow fiber were studied as a mean for separation and enrichment of studied polyamines from urine and tissue samples in order to prepare samples to be analyzed by HPLC. Conclusions Developed extraction systems offer an…
Green solvents and Ultrasound-Assisted Extraction of bioactive orange (Citrus sinensis) peel compounds.
2019
AbstractByproducts such as orange peel have potential uses because of their bioactive compounds, which are important for their potential to reduce the risk factors of diseases caused by aging. The lack of effective techniques and the high levels of pollution produced by the conventional extraction of bioactive compounds using organic solvents have highlighted the need to enhance the ‘green chemistry’ trend. This study evaluates the use of ultrasound to extract bioactive compounds from orange peel. The antioxidant capacity, phenolic content, ascorbic acid, total carotenoids, and HPLC profile of phenolic compounds from orange peel extracts were obtained by a physicochemical evaluation. The re…
International descriptive and interventional survey for oxycholesterol determination by gas- and liquid-chromatographic methods
2018
International audience; Increasing numbers of laboratories develop new methods based on gas-liquid and high-performance liquid chromatography to determine serum concentrations of oxygenated cholesterol metabolites such as 7alpha-, 24(S)-, and 27-hydroxycholesterol. We initiated a first international descriptive oxycholesterol (OCS) survey in 2013 and a second interventional survey 2014 in order to compare levels of OCS reported by different laboratories and to define possible sources of analytical errors. In 2013 a set of two lyophilized serum pools (A and B) was sent to nine laboratories in different countries for OCS measurement utilizing their own standard stock solutions. In 2014 eleven…
Virgin olive oil enriched with its own phenolic compounds or complemented with thyme improves endothelial function: The potential role of plasmatic f…
2017
The aim of the present study was to assess whether different functional virgin olive oils (FVOOs) with varying phenolic compounds (PC) could protect the plasmatic fat-soluble vitamins, which in turn could improve the endothelial function. In order to select the optimal phenolic dose in the improvement of ischemic reactive hyperemia (IRH), a dose-response study (n = 12, healthy subjects) was performed and the enrichment of 500 mg PC/kg oil was selected. In a 3-week cross-over sustained study (n = 33 hypercholesterolemic subjects), the consumption of 25 mL/day of two phenol-enriched olive oils (one enriched with its own PC and another combined with thyme PC) increased IRH and plasma concentra…
Newest Strategies in the Search for Bioactive Saponins from the Tropical Plant Biodiversity.
2016
This review will focus on newest results leading to the discovery of new bioactive saponins by using a combination of successive advanced procedures in extraction, isolation, structure elucidation and bioassays. Microwave- and ultrasonic-assisted extractions, two recent advanced methods have been increasingly used in the last decade. Then, a multistep purification procedure was achieved by flash chromatography, vacuum liquid chromatography, low, medium- and high-pressure liquid chromatography on silica gel and reversed-phase silica gel RP-18 (VLC, LPLC, MPLC, HPLC). These successive chromatographic steps have been implemented in the author's laboratory in order to avoid the time-consuming t…
In vivo effect of N-ethylmaleimide (NEM) on the measurement of nitrate in plasma
2016
Bioavailability of nitric oxide in the body may be estimated by measuring the concentration of nitrate in plasma. However, it has not been reported whether sequestering of aminothiols in plasma affects the concentration of nitrate in the samples.N-ethylmaleimide (NEM) sequesters aminothiols in plasma therefore we tested the in vivo effect of NEM on the concentration nitrate in plasma.Blood samples were collected from 56 healthy subjects in EDTA vials, EDTA vials containing PBS (pH7.4) and EDTA vials containing NEM dissolved in PBS. Nonparametric statistical tests were used to study the effect of NEM on the concentration of nitrate in plasma measured by the Griess reagent assay and by an HPL…
Development of an Analytical Assay for Electrochemical Detection and Quantification of Protein-Bound 3-Nitrotyrosine in Biological Samples and Compar…
2020
Reactive oxygen and nitrogen species (RONS) cause oxidative damage, which is associated with endothelial dysfunction and cardiovascular disease, but may also contribute to redox signaling. Therefore, their precise detection is important for the evaluation of disease mechanisms. Here, we compared three different methods for the detection of 3-nitrotyrosine (3-NT), a marker of nitro-oxidative stress, in biological samples. Nitrated proteins were generated by incubation with peroxynitrite or 3-morpholino sydnonimine (Sin-1) and subjected to total hydrolysis using pronase, a mixture of different proteases. The 3-NT was then separated by high performance liquid chromatography (HPLC) and quantifi…
Fast UPLC/PDA determination of squalene in Sicilian P.D.O. pistachio from Bronte: Optimization of oil extraction method and analytical characterizati…
2017
Abstract A fast reversed-phase UPLC method was developed for squalene determination in Sicilian pistachio samples that entry in the European register of the products with P.D.O. In the present study the SPE procedure was optimized for the squalene extraction prior to the UPLC/PDA analysis. The precision of the full analytical procedure was satisfactory and the mean recoveries were 92.8 ± 0.3% and 96.6 ± 0.1% for 25 and 50 mg L−1 level of addition, respectively. Selected chromatographic conditions allowed a very fast squalene determination; in fact it was well separated in ∼0.54 min with good resolution. Squalene was detected in all the pistachio samples analyzed and the levels ranged from 5…