Search results for "humid"
showing 10 items of 334 documents
Evaluating the protecting effects of two consolidants applied on Pietra di Lecce limestone: A neutronographic study
2020
Abstract In this work a combined laboratory-based and neutronographic investigation was carried out on a type of limestone, known as Pietra di Lecce stone, widely used in Italian Baroque as construction material. The limestone was treated with two different commercially-available coatings, namely nanosilica and nanolime, and artificially weathered by salt crystallization and temperature/relative humidity jumps. The aim was to provide an experimental evidence of the protective and consolidating effectiveness of the two treatments by looking at the water absorption process occurring inside the pore network of the analyzed stones. The analysis of the wetting front position revealed significant…
Long-lived contrails and convective cirrus above the tropical tropopause
2017
Abstract. This study has two objectives: (1) it characterizes contrails at very low temperatures and (2) it discusses convective cirrus in which the contrails occurred. (1) Long-lived contrails and cirrus from overshooting convection are investigated above the tropical tropopause at low temperatures down to −88 °C from measurements with the Russian high-altitude research aircraft M-55 Geophysica, as well as related observations during the SCOUT-O3 field experiment near Darwin, Australia, in 2005. A contrail was observed to persist below ice saturation at low temperatures and low turbulence in the stratosphere for nearly 1 h. The contrail occurred downwind of the decaying convective system H…
Impact of Convectively Detrained Ice Crystals on the Humidity of the Tropical Tropopause Layer in Boreal Winter
2020
Deep convection detraining in the uppermost tropical troposphere is capable of transporting water vapor and ice into the tropical tropopause layer (TTL), but the impact of deep convection on the global and regional TTL water vapor budget remains uncertain. In particular, the role of convectively detrained ice crystals that remain suspended after active convection has subsided is not well understood. These ice crystals represent aging cirrus anvils detached from the convective core. We use a cloud microphysical model that tracks individual ice crystals throughout their lifetimes to quantify the impact of detrained ice on the humidity of the TTL during boreal winter. Convective influence of a…
Natural Convection Cooling of a Hot Vertical Wall Wet by a Falling Liquid Film
2008
Abstract The system studied is a plane channel in which one of the two vertical walls is kept at an arbitrary temperature profile and may be partially or completely wet by a falling liquid film, while the opposite wall is adiabatic. Air from the environment flows along the channel with a mass flow rate which depends on the balance between hydraulic resistances and buoyancy forces. These latter, in their turn, depend on the distribution of temperature and humidity (hence, density) along the channel and eventually on the heat and mass transferred from wall and film to the humid air. A simplified computational model of the above system was developed and applied to the prediction of relevant qu…
A simple model to estimate the daily value of the regional maximum evapotranspiration from satellite temperature and albedo images
1987
Abstract We have tried an adaptation of the radiation model proposed by FAO, applicable in any area, for the estimation of the regional maximum evapotranspiration, ET, from temperature and albedo images obtained from a satellite. This model is based on the relationships ETm = k cETo ETo = A + BR g + CR g Ta max where k c is the crop coefficient, ETo is the maximum evapotranspiration of the reference crop (green grass), Rg is the global radiation obtained from satellite albedo images, T a max is the maximum temperature of the air obtained from the near-midday satellite temperature and A, B and C are the empirical coefficients characteristic of each zone calculated for different intervals of …
Degradation study of XVIII century graffiti on the walls of Chiaramonte Palace (Palermo, Italy)
2010
A systematic investigation of the original materials and the degradation phenomena induced by soluble salts on the wall matrix and on the graffiti of the Inquisition jails of Chiaramonte Palace in Palermo (Italy) was carried out. Built in the XIV century, Chiaramonte Palace was used as Inquisition court during the XV–XVI centuries. The ancient graffiti, recently discovered, represent a unique historical witness of the prisoners that lived during that terrible period. In order to study the nature, the amount and the distribution of the salts in the masonry, stone materials sampled at different depth from the wall matrix and saline efflorescences were analysed. Different physical techniques w…
Indoor air quality in schools of a highly polluted south Mediterranean area
2019
This study aimed at surveying lower secondary schools in southern Italy, in a highly polluted area. A community close to an industrial area and three villages in rural areas was investigated. Indoor temperature, relative humidity (RH), gaseous pollutants (CO 2 and NO 2 ), selected biological pollutants in indoor dust, and the indoor/outdoor mass concentration and elemental composition of PM 2.5 were ascertained. Temperature and RH were within, or close to, the comfort range, while CO 2 frequently exceeded the threshold of 1000 ppm, indicating inadequate air exchange rate. In all the classrooms, median NO 2 levels were above the WHO threshold value. Dermatophagoides p. allergen concentration…
Simplified models for the performance evaluation of desiccant wheel dehumidification
2002
In the present communication, simple models have been presented to evaluate the performance of rotary desiccant wheels based on different kind of solid desiccants e.g. silica gel and LiCl. The first part of the paper presents ‘Model 54’ which is developed for silica gel desiccant rotor. The model has been derived from the interpolation of experimental data obtained from the industry and the correlations have been developed for predicting outlet temperature and absolute humidity. The ‘Model 54’ consists of 54 coefficients corresponding to each correlation for outlet absolute humidity and temperature and it is found that the model predicts very well the performance of silica gel desiccant rot…
Experimental results on adsorption beds for air dehumidification
2016
Desiccant rotors are commonly used in large scale solar cooling open cycle applications. As is well known, adsorption heat sensibly reduces the dehumidification capacity of the desiccant material and results in lower system performance. The aim of this work is to describe an innovative solution that permits simultaneous mass and heat transfer. In particular, two components working with silica gel fixed beds were studied and compared. The first component is a simple packed bed containing silica gel grains. The second component is a fin and tube heat exchanger commonly used in several air conditioning applications wherein the spaces between the fins are filled with silica gel grains. In this …
Powder X-Ray Diffraction Investigation of Xylazine Hydrochloride Solid Phase Transformation Kinetics
2013
The kinetics of the solid-state phase transformation of xylazine hydrochloride form X to A has been investigated using powder X-ray diffraction and differential thermal analysis. Three different kinetic models have been used to describe transition kinetics: the Avrami–Erofeev equation, the Cardew equation, and the methodology for simulation of solid-state phase transition kinetics by the combination of nucleation and nuclei growth processes. The latter has been recently developed and has been tested in this paper for the case of a real solid-state transition. The relative humidity, mechanical pressure, temperature, and sample-preparation effect on phase-transition kinetics have been investi…