Search results for "image resolution"
showing 10 items of 377 documents
Development of a 3D CZT Spectrometer System with Digital Readout for Hard X/Gamma-Ray Astronomy
2019
We report on the development and of a complete X/γ rays detection system (10-1000 keV) based on CZT spectrometers with spatial resolution in three dimensions (3D) and a digital electronics acquisition chain. The prototype is made by packing four linear modules, each composed of one 3D CZT sensors. Each sensors is realized using a single spectroscopic graded CZT crystal of about 20×20×5 mm3. An electrode structure consisting of 12 collecting anodes with a pitch of 1.6 mm and 3 drift strips between each pair of anodes for 48 strips (0.15 mm wide) on the anodic side was adopted. The cathode is made of 10 strips with a pitch of 2 mm and orthogonal to anode side strips. Since the reading of the …
Metalenses with high-NA, enhanced resolution and apodization
2017
Dielectric microlenses employed in imaging and focusing for optoelectronics are currently prospects to be substituted by metalenses showing an extraordinary optical performance within notably reduced volumes. Here we present some proposals to achieve an enhanced resolution in metallodielectric metasurface-based lenses established on either efficient arrangements with high numerical aperture or spatial filtering enabling to surpass the limit of resolution derived by the Rayleigh criterion.
Femtosecond digital lensless holographic microscopy to image biological samples
2013
The use of femtosecond laser radiation in digital lensless holographic microscopy (DLHM) to image biological samples is presented. A mode-locked Ti:Sa laser that emits ultrashort pulses of 12 fs intensity FWHM, with 800 nm mean wavelength, at 75 MHz repetition rate is used as a light source. For comparison purposes, the light from a light-emitting diode is also used. A section of the head of a drosophila melanogaster fly is studied with both light sources. The experimental results show very different effects of the pinhole size on the spatial resolution with DLHM. Unaware phenomena on the field of the DLHM are analyzed.
High-Spatial-Resolution Monitoring of Strong Magnetic Field using Rb vapor Nanometric-Thin Cell
2011
We have implemented the so-called $\lambda$-Zeeman technique (LZT) to investigate individual hyperfine transitions between Zeeman sublevels of the Rb atoms in a strong external magnetic field $B$ in the range of $2500 - 5000$ G (recently it was established that LZT is very convenient for the range of $10 - 2500$ G). Atoms are confined in a nanometric thin cell (NTC) with the thickness $L = \lambda$, where $\lambda$ is the resonant wavelength 794 nm for Rb $D_1$ line. Narrow velocity selective optical pumping (VSOP) resonances in the transmission spectrum of the NTC are split into several components in a magnetic field with the frequency positions and transition probabilities depending on th…
Laser Beam Induced Current measurements on Dye Sensitized Solar Cells and thin film CIG(S,SE)<inf>2</inf> modules
2017
Calculating the efficiency of a solar cell depends on a precise knowledge of its area. Indeed, the photoresponse uniformity is essential to improve the manufacturing process. In this work we report on Laser Beam Induced Current measurements performed on CIG(S,Se) 2 modules and Dye Sensitized Solar Cells. These measurements, performed via a green and a red HeNe lasers both operating at an optical irradiance of 1 Sun, allowed to obtain an accurate photoresponse map of the specimens and highlighted the non-uniformities with a spatial resolution of 400 µm and 80 µm, respectively.
Single molecule imaging using a highly confined optical field at a triangular aperture
2005
We demonstrate that scanning near-field optical microscopy based on a probe with a triangular aperture is capable of imaging single fluorescent molecules with an optical resolution of 30 nm. Numerical simulations agree well with experiment.
Long axial crystals for PET applications: The AX-PET demonstrator and beyond
2013
The usage of long, axially oriented scintillator crystals in a PET scanner has been shown by the AX-PET Demonstrator as a possible solution for a high resolution and high sensitivity PET detector. In the AX-PET implementation, arrays of wavelength shifting (WLS) strips, placed orthogonally behind every crystal layer, are used to define the axial coordinate. After extensive characterization measurements, the AX-PET Demonstrator has been successfully used for the reconstruction of several phantoms and a few rodents. Possible extensions of the AX-PET concept towards Time Of Flight capabilities have been investigated, using Philips digital SiPMs as alternative photodetector. Promising CRT value…
Magnetic Field Gradiometer with Sub-Micron Spatial Resolution Based on Caesium Vapour in an Extremely Thin Cell
2015
Abstract In this paper we present a device for measuring the magnetic field and its gradient with a spatial resolution of several hundred nanometres. This device is based on caesium metal vapour confined to an extremely thin cell (ETC). To measure magnetic signals, we use absorption and very low laser powers, which might be appealing for modern fabrication techniques. A portable, fully automated device was constructed.
Spatial and spectral properties of small area THz generation for sub-wavelength microscopy
2010
A highly localized THz source is a promising candidate for sub-wavelength microscopy, due to its superior radiation power throughput with respect to others near-field techniques. Here, we report on the spatial and the spectral near-field properties of our highly localized THz source.
SU-E-I-83: Detectability Limits of a New Positron Emission Mammography in Relation to Tumour-Size, Tumour-To-Background Ratio and Activity Concentrat…
2017
Purpose:Positron emission mammography(PEM) improves spatial resolution and sensitivity, making it suitable for early breast tumours detection. The aim of this study is to evaluate the limits of a dedicated breast PET in terms of tumour‐size, tumour‐to‐background activity concentration ratio (TBR) and activity concentration. Methods: A dedicated PEM is evaluated. To characterize the device, we use a phantom of 15 cm of diameter containing 6 inserts of inner diameters 18, 15, 11, 8, 5 and 3 mm. To evaluate the detectability limits images are acquired by varying the TBR from 10 to 2 and without background activity concentration. In all the studies the activity concentration for the 6 inserts i…