Search results for "imagin."
showing 10 items of 7170 documents
"Dangerous liaisons: NAFLD and liver fibrosis increase cardiovascular risk in HIV".
2022
Objectives Non-alcoholic fatty liver disease (NAFLD) is strongly associated with cardiovascular disease in the general population. We aimed to assess the impact of NAFLD and liver fibrosis on intermediate-high cardiovascular risk in people living with HIV. Methods We included people living with HIV from three cohorts. NAFLD and significant liver fibrosis were defined using transient elastography: controlled attenuation parameter >= 288 dB/m and liver stiffness measurement >= 7.1 kPa, respectively. Cardiovascular risk was assessed with the atherosclerotic cardiovascular disease (ASCVD) risk estimator in patients aged between 40 and 75 years and categorised as low if <5%, borderline …
Suboptimal performance of APRI and FIB-4 in ruling out significant fibrosis and confirming cirrhosis in HIV/HCV co-infected and HCV mono-infected pat…
2018
Purpose: We aimed to assess the diagnostic reliability of two indirect biomarkers, APRI and FIB-4, for the staging of liver fibrosis using transient elastography (TE) as reference standard, among HIV/HCV co-infected and HCV mono-infected patients. Methods: This is an observational, retrospective study on subjects who had access to the RESIST HCV from October 2013 to December 2016, a regional network encompassing 22 hospitals and academic centers throughout Sicily. Sensitivity, specificity and diagnostic accuracy of indirect biomarkers for liver stiffness measurement (LSM) < 9.5 kPa (significant fibrosis) and LSM ≥ 12.5 kPa (cirrhosis) were determined by receiver operator characteristics …
Usefulness of the index of NASH - ION for the diagnosis of steatohepatitis in patients with non-alcoholic fatty liver: An external validation study
2018
Background & Aims The non-invasive identification of steatohepatitis (NASH) in patients with Non-Alcoholic Fatty Liver Disease is an unmet need in clinical practice. Index of NASH (ION) is a new tool for the prediction of NASH. We aimed to externally validate ION and to compare it with CK-18. Since necroinflammation precedes fibrosis, we also tested ION in combination with non-invasive tools for fibrosis. Methods We analysed data from 292 Italian patients (169 Southern cohort, and 123 Northern cohort) with an histological diagnosis of NAFLD. The ION, FIB-4 and NFS scores were calculated according to published algorithms. Serum cytokeratin18-Aspartate396 levels and liver stiffness (LS) by Fi…
Comparison of Histochemical Stainings in Evaluation of Liver Fibrosis and Correlation with Transient Elastography in Chronic Hepatitis.
2015
Background and Aim. The best staining to evaluate liver fibrosis in liver hepatitis is still a debated topic. This study aimed to compare Masson’s trichrome (MT), Sirius Red (SR), and orcein stainings in evaluating liver fibrosis in chronic HCV hepatitis (CHC) with semiquantitative and quantitative methods (Collagen Proportionate Area (CPA) by Digital Image Analysis (DIA)) and correlate them with transient elastography (TE).Methods. Liver stiffness evaluation of 111 consecutive patients with CHC was performed by TE. Semiquantitative staging by Metavir score system and CPA by DIA were assessed on liver biopsy stained with MT, SR, and orcein.Results. MT, SR, and orcein staining showed concord…
Prospective comparison of Fibroscan, King's score and liver biopsy for the assessment of cirrhosis in chronic hepatitis C infection
2010
Historically, liver biopsy (LB) was the sole method to evaluate the severity of hepatic fibrosis in patients with chronic hepatitis C infection. However, LB is expensive and associated with a risk of severe complications. Therefore, noninvasive tests have been developed to assess the severity of liver fibrosis. The accuracy of Fibroscan (FS) and King's score (KS) was evaluated individually and in combination using liver histology as the reference standard. One hundred and eighty-seven patients were identified who had undergone a biopsy with a diagnosis of chronic hepatitis C virus (HCV) mono-infection (HCV RNA-positive by RT-PCR), attending King's College Hospital (n = 88) or the Royal Free…
Metabolite identification in human liver needle biopsies by high-resolution magic angle spinning1H NMR spectroscopy
2006
High-resolution magic angle spinning (HR-MAS) 1 H NMR spectroscopy of intact human liver needle biopsies has not been previously reported. HR-MAS NMR spectra collected on 17 specimens with tissue amounts between � 0.5 and 12 mg showed very good spectral resolution and signal-to-noise ratios. One-dimensional 1 H spectra revealed many intense signals corresponding to cellular metabolites. In addition, some high molecular weight metabolites, such as glycogen and mobile fatty acids, could be observed in some spectra. Resonance assignments for 22 metabolites were obtained by combining the analysis of three different types of 1D 1 H spectral editing, such as T2 filtering or the nuclear Overhauser…
Focal lesions in cirrhotic liver: what else beyond hepatocellular carcinoma?
2014
Detection and characterization of focal lesions in the cirrhotic liver may pose a diagnostic dilemma. Several benign and malignant lesions may be found in a cirrhotic liver along with hepatocellular carcinoma (HCC), and may exhibit typical or atypical imaging features. In this pictorial essay, we illustrate computed tomography and magnetic resonance imaging findings of lesions such as simple bile duct cysts, hemangioma, focal nodular hyperplasia-like nodules, peribiliary cysts, intrahepatic cholangiocarcinoma, lymphoma, and metastases, all of which occur in cirrhotic livers with varying prevalences. Pseudolesions, such as perfusion anomalies, focal confluent fibrosis, and segmental hyperpla…
In vivo confocal laser endomicroscopy of the human liver: a novel method for assessing liver microarchitecture in real time
2008
Background and study aims Confocal endomicroscopy is a unique novel tool for in vivo histology in humans. Due to limitations imposed by the form of the equipment and by sterilization workflows, its use has been limited to the gastrointestinal tract so far. We have developed a rigid miniaturized probe for confocal endomicroscopy of the human liver during laparoscopy. Patients and methods To assess the feasibility and potential clinical value of this new system (diameter 6.3 mm), 25 patients with liver disease were examined during routine minilaparoscopy under conscious sedation. Results Subsurface serial images (from surface to 250 microm) were generated in real time after fluorescein inject…
Hepatocellular carcinoma in cirrhotic patients at multidetector CT: hepatic venous phase versus delayed phase for the detection of tumour washout.
2011
OBJECTIVES: Our aim was to compare retrospectively hepatic venous and delayed phase images for the detection of tumour washout during multiphasic multidetector row CT (MDCT) of the liver in patients with hepatocellular carcinoma (HCC). METHODS: 30 cirrhotic patients underwent multiphasic MDCT in the 90 days before liver transplantation. MDCT was performed before contrast medium administration and during hepatic arterial hepatic venous and delayed phases, images were obtained at 12, 55 and 120 s after trigger threshold. Two radiologists qualitatively evaluated images for lesion attenuation. Tumour washout was evaluated subjectively and objectively. Tumour-to-liver contrast (TLC) was measured…
Modified spleen stiffness measurement by transient elastography is associated with presence of large oesophageal varices in patients with compensated…
2013
To evaluate the accuracy of liver transient elastography (TE), spleen TE and other noninvasive tests (AAR, APRI score, platelet count, platelet/spleen ratio) in predicting the presence and the size of oesophageal varices in compensated hepatitis C virus (HCV) cirrhosis, we studied 112 consecutive patients with compensated HCV cirrhosis who underwent biochemical tests, gastrointestinal endoscopy, liver TE and spleen TE by Fibroscan(®) (Echosens, Paris, France) using a modified software version with a range between 1.5 and 150 kPa. Spleen TE was not reliable in 16 patients (14.3%). Among the 96 patients with a valid measurement (69.8% men, mean age: 63.2 ± 9.5 years), 43.7% had no oesophageal…