Search results for "implantation"

showing 10 items of 733 documents

Cryptogenic stroke and atrial fibrillation in a real-world population: the role of insertable cardiac monitors

2020

AbstractThe incidence of atrial fibrillation (AF) in cryptogenic stroke (CS) patients has been studied in carefully controlled clinical trials, but real-world data are limited. We investigated the incidence of AF in clinical practice among CS patients with an insertable cardiac monitor (ICM) placed for AF detection. Patients with CS admitted to our Stroke Unit were included in the study; they received an ICM and were monitored for up to 3 years for AF detection. All detected AF episodes of at least 120 sec were considered. From March 2016 to March 2019, 58 patients (mean age 68.1 ± 9.3 years, 67% male) received an ICM to detect AF after a CS. No patients were lost to follow-up. AF was detec…

Malelcsh:MedicineKaplan-Meier Estimate030204 cardiovascular system & hematologySeverity of Illness Index0302 clinical medicineRisk Factorslcsh:ScienceStrokeMultidisciplinaryIncidence (epidemiology)QRNeuro-vascular interactionsAtrial fibrillationICM deviceStrokeTreatment OutcomeCardiologyMedicineFemaleSettore MED/26 - Neurologiamedicine.symptommedicine.medical_specialtyScienceNeurophysiologyCryptogenic strokeAsymptomaticArticleProsthesis ImplantationLoop recorder03 medical and health sciencesInternal medicinemedicineHumansAgedMonitoring Physiologicbusiness.industrylcsh:RAnticoagulantsmedicine.diseaseAtrial fibrillationClinical trialCryptogenic strokeAnticoagulant therapyElectrocardiography AmbulatoryCardiac monitorslcsh:Qbusiness030217 neurology & neurosurgeryFollow-Up StudiesScientific Reports
researchProduct

Series of fibrinous inflammation after implantation of capsular tension rings

2014

Purpose To analyze the cause of fibrinous inflammation in eyes with capsular tension rings (CTRs) after cataract surgery. Setting Department of Ophthalmology, University Medical Center, Johannes Gutenberg-University Mainz, Mainz, Germany. Design Retrospective case series. Methods High-performance liquid chromatography was implemented to eliminate impurities. One CTR was explanted for microbiologic examination. The pH values of the CTR and the storage solution were analyzed, Seldi and Maldi tests were performed, as well as toxicity tests with immortal cell lines. Material batches were analyzed. The organic carbon content of CTRs, detergents, and storage solutions was checked. The presence of…

Malemedicine.medical_specialtyAfter cataractTopical treatmentMethylmethacrylatemedicine.disease_causeProsthesis ImplantationPostoperative ComplicationsLens Implantation IntraocularOphthalmologymedicineHumansUniversity medicalDevice RemovalAgedRetrospective StudiesAged 80 and overEndophthalmitisFibrinPhacoemulsificationAmoebocyte lysatebusiness.industrySmear testsFibrinous inflammationProstheses and ImplantsMiddle AgedSensory SystemsSurgeryOphthalmologyMethacrylatesFemaleSurgeryIrritationbusinessJournal of Cataract and Refractive Surgery
researchProduct

ECG-GATED MULTIDETECTOR COMPUTED TOMOGRAPHY FOR THE ASSESSMENT OF THE POSTOPERATIVE ASCENDING AORTA

2009

This study was undertaken to define the role of electrocardiographically (ECG)-gated multidetector computed tomography (MDCT) in the assessment of the postoperative ascending aorta. From November 2006 to June 2007, 21 patients, [11 men, ten women; age +/- standard deviation (SD): 62.7 +/- 10.8 years] with a history of ascending aorta replacement underwent ECG-gated MDCT and were prospectively included in our study. Ascending aorta replacement had been performed with different surgical techniques: Bentall-De Bono (four patients, 19%), Tirone-David (five patients, 23%), and modified Tirone-David with creation of aortic neosinuses (12 patients, 57%). Two patients were excluded from MDCT evalua…

Malemedicine.medical_specialtyAortic DiseasesContrast MediaAorta ThoracicBlood Vessel Prosthesis ImplantationElectrocardiographyPostoperative ComplicationsAortic valve replacementECG gatingmedicine.arteryAscending aortaMultidetector computed tomographymedicineHumansRadiology Nuclear Medicine and imagingAortic valve prosthesicardiovascular diseasesAortaNeuroradiologyAortamedicine.diagnostic_testbusiness.industryMultidetector CTUltrasoundInterventional radiologySettore MED/23 - Chirurgia CardiacaGeneral MedicineMiddle Agedmedicine.diseaseIopamidolAortic valve replacementTreatment OutcomeEchocardiographyEcg gatingcardiovascular systemRadiographic Image Interpretation Computer-AssistedFemaleRadiologybusinessTomography X-Ray ComputedSettore MED/36 - Diagnostica Per Immagini E Radioterapia
researchProduct

Computed Tomography-Aortography Versus Color-Duplex Ultrasound for Surveillance of Endovascular Abdominal Aortic Aneurysm Repair: A Prospective Multi…

2020

Background Color-duplex ultrasonography (DUS) could be an alternative to computed tomography-aortography (CTA) in the lifelong surveillance of patients after endovascular aneurysm repair (EVAR), but there is currently no level 1 evidence. The aim of this study was to assess the diagnostic accuracy of DUS as an alternative to CTA for the follow-up of post-EVAR patients. Methods Between December 16, 2010, and June 12, 2015, we conducted a prospective, blinded, diagnostic-accuracy study, in 15 French university hospitals where EVAR was commonly performed. Participants were followed up using both DUS and CTA in a mutually blinded setup until the end of the study or until any major aneurysm-rel…

Malemedicine.medical_specialtyAortographyTime FactorsComputed Tomography Angiographymedicine.medical_treatmentComputed tomographyDiagnostic accuracy030204 cardiovascular system & hematology030230 surgeryLikelihood ratios in diagnostic testingEndovascular aneurysm repairAortography03 medical and health sciencesBlood Vessel Prosthesis Implantation0302 clinical medicinePostoperative ComplicationsPredictive Value of TestsColor duplex ultrasoundMultidetector Computed TomographymedicineHumansRadiology Nuclear Medicine and imagingProspective StudiesUltrasonography Doppler ColorProspective cohort studyAgedAged 80 and overmedicine.diagnostic_testbusiness.industryEndovascular ProceduresReproducibility of Resultsmedicine.diseaseAbdominal aortic aneurysmTreatment OutcomeRetreatmentFemaleRadiologyFranceCardiology and Cardiovascular MedicinebusinessAortic Aneurysm AbdominalCirculation. Cardiovascular imaging
researchProduct

Development of a coronary aneurysm 6 months after stent implantation assessed by intracoronary ultrasound.

1996

Malemedicine.medical_specialtyArterial diseasemedicine.medical_treatmentCoronary DiseaseAneurysmmedicineStent implantationHumansAngioplasty Balloon CoronaryUltrasonographyVascular diseasebusiness.industryCoronary AneurysmStentMiddle Agedmedicine.diseaseCoronary VesselsCoronary heart diseaseSurgeryIntracoronary ultrasoundStentsRadiologyCardiology and Cardiovascular MedicinebusinessComplicationAmerican heart journal
researchProduct

Use of engineered bone for sinus augmentation.

2008

Tissue-engineered bone grafts represent an appealing alternative for maxillary sinus augmentation because they eliminate the significant drawbacks associated with extra- and intraoral bone-harvesting procedures. In the present case series, we document the outcomes of sinus augmentation surgery using tissue-engineered bone grafts.Three patients requiring bilateral sinus augmentation received tissue-engineered bone grafts combined with xenograft prior to implant placement. Implants were placed and loaded 6 and 12 months postaugmentation, respectively. Radiographs were taken and clinical examinations were performed preoperatively and at 4, 6, 12, and 18 months postaugmentation. Biopsies were o…

Malemedicine.medical_specialtyBone RegenerationMaxillary sinusRadiographyDentistryBone MatrixOral Surgical ProceduresPeriosteummedicineHumansBone regenerationPolyglactin 910Sinus (anatomy)Bone TransplantationOsteoblastsTissue EngineeringTissue Scaffoldsbusiness.industryDental Implantation EndosseousGeneral EngineeringMaxillary SinusMiddle AgedSurgeryImplant placementmedicine.anatomical_structurePeriodonticsFemaleImplantbusinessPosterior maxillaOral Surgical Procedures PreprostheticJournal of periodontology
researchProduct

?Reliability of new poly (lactic-co-glycolic acid) membranes treated with oxygen plasma plus silicon dioxide layers for pre-prosthetic guided bone re…

2017

Background: The use of cold plasmas may improve the surface roughness of poly(lactic-co-glycolic) acid (PLGA) membranes, which may stimulate the adhesion of osteogenic mediators and cells, thus accelerating the biodegradation of the barriers. Moreover, the incorporation of metallic-oxide particles to the surface of these membranes may enhance their osteoinductive capacity. Therefore, the aim of this paper was to evaluate the reliability of a new PLGA membrane after being treated with oxygen plasma (PO) plus silicon dioxide (SiO) layers for guided bone regeneration (GBR) processes. Material and Methods: Circumferential bone defects (diameter: 11 mm; depth: 3 mm) were created on the top of ei…

Malemedicine.medical_specialtyBone RegenerationSilicon dioxide02 engineering and technologyBone tissue03 medical and health scienceschemistry.chemical_compound0302 clinical medicinePolylactic Acid-Polyglycolic Acid CopolymermedicineAnimalsLactic AcidBone regenerationGeneral DentistryGlycolic acidNanocompositeResearchoxygen plasma (PO2)technology industry and agricultureMembraneMembranes Artificial030206 dentistryAdhesionBiodegradationSilicon Dioxide021001 nanoscience & nanotechnology:CIENCIAS MÉDICAS [UNESCO]SurgeryOxygenDental ImplantationPLGASilicon dioxide layersmedicine.anatomical_structureMembraneOtorhinolaryngologychemistryUNESCO::CIENCIAS MÉDICASGuided Tissue Regeneration PeriodontalSurgeryRabbitsOral Surgery0210 nano-technologyPolyglycolic AcidPoly(lactic-co-glycolic acid) (PLGA)Guided bone regeneration (GBR)Biomedical engineering
researchProduct

Tumor Marker Carbohydrate Antigen 125 Predicts Adverse Outcome After Transcatheter Aortic Valve Implantation

2013

ObjectivesThis study sought to predict the value of tumor marker carbohydrate antigen 125 (CA125) before and after transcatheter aortic valve implantation (TAVI) for all-cause death and a composite endpoint of death, admission for heart failure, myocardial infarction, and stroke (major adverse cardiac events [MACE]).BackgroundRisk stratification after TAVI remains challenging. The use of biomarkers in this setting represents an unmet need.MethodsCA125 was measured in 228 patients before and after TAVI. The association with outcomes was assessed using parametric Cox regression and joint modeling for baseline and longitudinal analyses, respectively. CA125 was evaluated as logarithm transforma…

Malemedicine.medical_specialtyCardiac CatheterizationTime FactorsAortic Valve InsufficiencyMyocardial InfarctionKaplan-Meier EstimateRisk AssessmentCA125Interquartile rangeRisk FactorsInternal medicineMedicineHumansMyocardial infarctionLongitudinal StudiesRegistriesStroketranscatheter aortic valve implantationTumor markerAgedProportional Hazards ModelsAged 80 and overHeart FailureHeart Valve Prosthesis ImplantationProportional hazards modelbusiness.industryMembrane ProteinsAortic Valve Stenosismedicine.diseasejoint modelingHospitalizationStrokeLogistic ModelsTreatment OutcomeCardiovascular DiseasesHeart failureCA-125 AntigenMultivariate AnalysisCardiologybiomarkerBiomarker (medicine)FemaleprognosisbusinessCardiology and Cardiovascular MedicineMaceBiomarkersJACC: Cardiovascular Interventions
researchProduct

Cardiopulmonary Hemodynamic Profile Predicts Mortality After Transcatheter Tricuspid Valve Repair in Chronic Heart Failure.

2020

This study was designed to assess hemodynamic changes in response to transcatheter tricuspid valve edge-to-edge repair (TTVR) and to identify hemodynamic predictors associated with mortality.Severe tricuspid regurgitation (TR) is associated with high mortality. TTVR effectively alleviates heart failure symptoms, but comprehensive hemodynamic characterization of patients undergoing TTVR is currently lacking.This international, multicenter study included 236 patients undergoing TTVR. Data from clinical assessment, echocardiography, intraprocedural right heart catheterization, and noninvasive cardiac output measurement were analyzed. Hemodynamic predictors for mortality were identified using l…

Malemedicine.medical_specialtyCardiac CatheterizationTime FactorsHemodynamicsRegurgitation (circulation)030204 cardiovascular system & hematologyNew york heart association03 medical and health sciences0302 clinical medicineInternal medicineMedicineHumans030212 general & internal medicineTRICUSPID VALVE REPAIRAgedHeart FailureHeart Valve Prosthesis ImplantationTricuspid valvebusiness.industryProportional hazards modelHemodynamicsRecovery of Functionmedicine.diseaseTricuspid Valve Insufficiencymedicine.anatomical_structureTreatment OutcomeMulticenter studyHeart failureCardiologyFemaleTricuspid ValveCardiology and Cardiovascular MedicinebusinessJACC. Cardiovascular interventions
researchProduct

Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement

2013

Background— Aortic root rupture is a major concern with balloon-expandable transcatheter aortic valve replacement (TAVR). We sought to identify predictors of aortic root rupture during balloon-expandable TAVR by using multidetector computed tomography. Methods and Results— Thirty-one consecutive patients who experienced left ventricular outflow tract (LVOT)/annular/aortic contained/noncontained rupture during TAVR were collected from 16 centers. A caliper-matched sample of 31 consecutive patients without annular rupture, who underwent pre-TAVR multidetector computed tomography served as a control group. Multidetector computed tomography assessment included short- and long-axis diameters an…

Malemedicine.medical_specialtyCardiac CatheterizationTranscatheter aorticAortic rootmedicine.medical_treatmentAortic Rupturemultidetector computed tomographySettore MED/11 - Malattie dell'Apparato CardiovascolareCohort StudiesValve replacementPredictive Value of TestsRisk FactorsPhysiology (medical)Internal medicineMultidetector computed tomographymedicine80 and overVentricular outflow tractHumanscardiovascular diseasesannular calcification; annular rupture; multidetector computed tomography; transcatheter heart valves; Aged; Aged 80 and over; Angioplasty Balloon; Aortic Rupture; Aortic Valve; Aortic Valve Stenosis; Calcinosis; Cohort Studies; Female; Heart Valve Prosthesis Implantation; Humans; Logistic Models; Male; Predictive Value of Tests; Risk Factors; Tomography X-Ray Computed; Cardiac CatheterizationTomographyAgedAged 80 and overHeart Valve Prosthesis Implantationbusiness.industrySinotubular JunctionAngioplastyCalcinosisAortic Valve Stenosismedicine.diseaseX-Ray ComputedBalloon expandable stentLogistic Modelstranscatheter heart valvesAortic ValveCardiologycardiovascular systemannular ruptureFemaleRadiologyCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedAngioplasty BalloonBalloonCalcificationannular calcification
researchProduct