Search results for "implants"
showing 10 items of 505 documents
Immediate post-extraction implants placed in acute periapical infected sites with immediate prosthetic provisionalization : a 1-year prospective coho…
2020
Background Few studies have reported the outcomes of immediate placement at infected post-extraction sites. The aim of this study was to compare clinical and radiological outcomes of immediately placed implants with immediate prosthetic provisionalization in sockets with or without acute periapical pathology. Material and Methods A total of 100 patients with immediately placed implants with immediate provisionalization and 1- year of follow up were included (50 patients with acute periapical pathology and a control group of 50 patients without acute periapical pathology). Clinical parameters (bleeding on probing, buccal keratinized mucosa width, clinical recession, and probing depth) and ra…
Volumetric variation of peri-implant soft tissues in convergent collar implants and crowns using the biologically oriented preparation technique (BOP…
2018
Background To evaluate the changes in the peri-implant soft tissues of convergent collar implants with biologically oriented preparation technique (BOPT) crowns, 10 months after loading. Material and Methods A pilot study was carried out from January 2016 to October 2017 involving 14 patients with one or two implants in the posterior mandibular sector. A total of 32 convergent collar implants were placed using a non-submerged protocol. Three months later the provisional cemented crowns were fitted using the BOPT approach with the finish line 1-1.5 mm below the gingival margin, simulating coronal emergence of a natural tooth. The soft tissue changes were measured with an intraoral scanner at…
Torque de desinserción y propiedades fisico-químicas de implantes dentales grabados con ácidos fluorhídrico y nítrico: Estudio experimental en perros
2006
Objetivo: Estudiar la composición, características superficiales y respuesta al torque de desinserción de una superficie implantaria tratada inicialmente con ácido fluorhídrico y posterior pasivado con ácidos fluorhídrico y nítrico. Diseño del estudio: En una primera fase, se seleccionaron 12 implantes en los que se estudiaron las características fisico-químicas mediante mediciones de energía dispersa de rayos X (EDS), microscopio electrónico de barrido y análisis de XPS (espectrometría de fotoelectrones). Asimismo, se colocaron 24 implantes -doce de 8 mm y doce de 10 mm de longitud-, en seis perros beagle, en los que tras un período de reposo, se procedió a la retirada de 12 implantes a la…
Effect of bone loss on the fracture resistance of narrow dental implants after implantoplasty. An in vitro study
2021
Background Implantoplasty (IP) involves polishing of the exposed surface of implants affected by peri-implantitis (PI). A study was made to determine whether the degree of bone loss influences the fracture resistance of implants with or without IP. Material and Methods An in vitro study was carried out on 32 narrow (3.5 mm) dental implants with a rough surface and external hexagonal connection. Implantoplasty was performed in half of the implants of the sample. Both the IP and control implants were divided into two subgroups according to the amount of bone loss (3 mm or 7.5 mm). Standardized radiographic assessment of implant width was performed using specific software. The main outcome var…
Tissue response and biomaterial integration: the efficacy of in vitro methods
2002
Implantation involves tissue trauma, which evokes an inflammatory response, coupled to a wound healing reaction, involving angiogenesis, fibroblast activation and matrix remodelling. Until now the type and extent of such reactions to give optimal integration of various biomaterials are practically unknown. Three principal fields of research can yield useful data to understand these phenomena better: studies on explanted biomaterials, animal models and relevant in vitro techniques. This paper will present examples of the latter field and the application of endothelial cell (EC) culture systems to study the effects of important tissue (e.g. pro-inflammatory cytokines, chemokines) and material…
Observational study: The use of the ventralight Echo PS (positioning system) prosthesis in the treatment of incisional hernia
2020
The treatment of incisional hernias, especially those that are multiple or recurring, has always represented important challenges for surgeons. An incisional hernia is a mechanical damage of the abdominal wall that can result in respiratory problems and alterations of splanchnic circulation, especially when in large size hernias. The increasing availability of prostheses with greater resistance Romato infections and tension, lightness, biocompatibility, and reduced visceral adhesions has improved outcomes and minimized relapses. It is still important, however, to carefully choose the type of prosthesis and surgical technique, whether laparotomic or laparoscopic, correlated to the positionin…
Infections in implantology: From prophylaxis to treatment
2007
Since the introduction of osseointegrated implant treatment, odontology, and in particular the area of prosthodontic replacement of lost teeth, has evolved in an unimaginable way, to the extent that the age-old idea of "restitutio ad integrum" has almost become possible. Implant treatment has a high success rate that has been rated as high as 95 to 99%, according to different casuists, but there is another group of cases in which implants fail, and in fact it is hard to know the causes of such failures. The microbiological component plays an important role in encouraging and facilitating implant infection during implant placement, and also later when the implant is in function in the mouth,…
Relation between bone density and primary implant stability
2010
Aims: This study aims to relate bone density in Hounsfield units (Hu) with the primary implant stability measured by insertion torque (Ncm) and resonance frequency analysis (ISQ). Materials and Methods: Ten patients were included in this study. A total of 54 implant sites were provided from 10 computerized tomography scans. The computerized tomography scan was used for the preoperative evaluation of bone density for each patient. The bone mean density around planned implants was determined with Physioplanet TM software. Bone quality according resistance to drilling, insertion torque and resonance frequency measurements were recorded. Results: A statistically significant relationship was obs…
Design characteristics, primary stability and risk of fracture of orthodontic mini-implants: Pilot scan electron microscope and mechanical studies
2013
Objectives: Orthodontic mini-implants (OMIs) are increasingly used in orthodontics but can fail for various reasons. This study investigates the effects of OMI design characteristics on the mechanical properties in artificial bone. Material and Methods: Twelve self-drilling OMIs (2 small, 6 medium, 4 large) from 8 manufacturers were tested for their primary stability in simulated medium-high cancellous bone and the risk to fracture in high-density methacrylate blocks. For the assessments of the maximum insertion torque (IT) and torsional fracture (TF) 5 of each OMI were used and for the pull-out strength (POS) 10. The OMIs were inserted with a torque screwdriver (12 sec/360°) until the bott…
Implant insertion torque value in immediate loading : a retrospective study
2019
Background The aim of this study is to verify if the Insertion Torque Value (ITV) of 32 Ncm for immediate loading protocol (ILP), as indicated by literature, is still, with the advance in implant research, a real significant cut-off for long-term implant survival. Material and Methods In this retrospective study, data from 224 patients that during three years of clinical practice, were submitted to the insertion of 322 implants with immediate loading protocol, have been recorded, pooled and analyzed. Data were organized based on Insertion Torque Value (ITV): > 32 Ncm (CG) and 32 Ncm are still characterized by a lower crestal bone resorption, there are no statistically significant difference…