Search results for "implants"
showing 10 items of 505 documents
Impression of multiple implants using photogrammetry: Description of technique and case presentation
2014
Aim: To describe a technique for registering the positions of multiple dental implants using a system based on photogrammetry. A case is presented in which a prosthetic treatment was performed using this technique. Study Design: Three Euroteknika® dental implants were placed to rehabilitate a 55-year-old male patient with right posterior maxillary edentulism. Three months later, the positions of the implants were registered using a photogrammetry-based stereo-camera (PICcamera®). After processing patient and implant data, special abut - ments (PICabutment®) were screwed onto each implant. The PICcamera® was then used to capture images of the implant positions, automatically taking 150 image…
Microbiological assessment of the implant-abutment interface in different connections: cross-sectional study after 5 years of functional loading.
2014
Objective To evaluate the bacterial microflora present inside the implant connection and in the peri-implant sulcus fluid of healthy implants, and to analyze the relationships between these harboring sites for four different implant systems after at least 5 years of functional loading. Materials and methods A cross-sectional study was performed involving 40 patients treated with metal-ceramic cemented bridges supported by at least two healthy implants functionally loaded for 5 years. Four different implant-abutment connections were studied: external hexagon (control group), double internal hexagon (test group 1), internal hexagon with external collar (test group 2), and conical connection (…
Silicone-Silver Penile Prosthesis: Description, Operative Approach and Results
1980
A silicone penile prosthesis in which silver wires are embedded to allow for voluntary bending of the penis for urination and resting position and for straightening for intercourse is described. The implantation is done via a hemicircular incision on the dorsum of the penis in the sulcus coronarius. Buck's fascia is identified and opened, and the corpora are dilated up to 30F. After the exact length is determined with a special sizer the prosthesis is slipped into each corpus cavernosum. The advantage of this approach is the optimal insertion of the prosthesis distal to the sulcus coronarius, thereby preventing kinking of the glans during intercourse. Our experiences with the implantation i…
Knowledge, aptitudes, and preferences in implant dentistry teaching/training among undergraduate dental students at the University of Barcelona
2017
Background Oral implant rehabilitation should be considered a treatment option for any edentulous patient and Implant Dentistry is currently a discipline taught in the undergraduate formation. The level of knowledge acquired and how the students perceive the quality of training in Implant Dentistry could assess to know if it is necessary to improve the syllabus. Material and Methods A questionnaire was developed with 11 questions: Basic knowledge (7); Perception of training received (2); Ways in which students would receive training (2). To be responded anonymously and voluntarily for undergraduates students in the Faculty of Dentistry (University of Barcelona, Spain). Results One hundred a…
Single-blind randomized clinical trial to evaluate clinical and radiological outcomes after one year of immediate versus delayed implant placement su…
2013
Purpose: To evaluate and compare peri-implant health, marginal bone loss and success of immediate and delayed implant placement for rehabilitation with full-arch fixed prostheses. Material and Methods: The present study was a prospective, randomized, single-blind, clinical preliminary trial. Patients were randomized into two treatment groups. In Group A implants were placed immediately post-extraction and in Group B six months after extraction. The following control time-points were established: one week, six months and twelve months after loading. Measurements were taken of peri-implant crevicular fluid volume, plaque index, gingival retraction, keratinized mucosa, probing depth, modified …
Orthodontic load on short maxillary implants with reduced sink depth: an experimental study.
2008
Objective The aim of this study was to investigate experimentally the positional stability and histomorphometric findings of length-reduced temporary anchorage devices (Orthosystem, length: 4 mm) with reduced sink depth. Material and methods For this purpose, four maxillary pre-molars ((2)P(2), (3)P(3)) were extracted from each of four foxhounds. After a 16-week alveolar healing period, 16 implants (four per dog) were inserted into the edentulous areas. Four implants (one per dog) were placed simultaneously in the mid-palatal area. The implants were intentionally submerged to about three-quarters of their length. After a 10-week unloaded implant healing period, the implants in the P3 areas …
Drilling dimension effects in early stages of osseointegration and implant stability in a canine model
2015
Background: This study histologically evaluated two implant designs: a classic thread design versus another specifically designed for healing chamber formation placed with two drilling protocols. Material and Methods: Forty dental implants (4.1 mm diameter) with two different macrogeometries were inserted in the tibia of 10 Beagle dogs, and maximum insertion torque was recorded. Drilling techniques were: until 3.75 mm (regular-group); and until 4.0 mm diameter (overdrilling-group) for both implant designs. At 2 and 4 weeks, samples were retrieved and processed for histomorphometric analysis. For torque and BIC (bone-to-implant contact) and BAFO (bone area fraction occupied), a general-linea…
A Randomized Trial of a Schlemm's Canal Microstent with Phacoemulsification for Reducing Intraocular Pressure in Open-Angle Glaucoma
2014
Purpose To assess the safety and effectiveness of the Hydrus Microstent (Ivantis, Inc, Irvine, CA) with concurrent cataract surgery (CS) for reducing intraocular pressure (IOP) in open-angle glaucoma (OAG). Design Prospective, multicenter, randomized, single-masked, controlled clinical trial. Participants One hundred eyes from 100 patients 21 to 80 years of age with OAG and cataract with IOP of 24 mmHg or less with 4 or fewer hypotensive medications and a washed-out diurnal IOP (DIOP) of 21 to 36 mmHg. Methods On the day of surgery, patients were randomized 1:1 to undergo CS with the microstent or CS alone. Postoperative follow-up was at 1 day, 1 week, and 1, 3, 6, 12, 18, and 24 months. Wa…
Biodegradable collagen matrix implant versus mitomycin-C in trabeculectomy: five-year follow-up.
2015
Background Clinical studies comparing trabeculectomy augmented with Ologen implant (OLO) versus trabeculectomy plus mitomycin-C (MMC) show contradictory results. To obtain long-term data, we report an extended 5-year follow-up trial evaluating the safety and efficacy of OLO as adjuvant compared to low-dosage MMC in trabeculectomy. Methods Forty glaucoma patients (40 eyes) assigned to trabeculectomy with MMC or Ologen. Primary outcome: target IOP at ≤21, ≤17 and ≤15 mmHg; complete and qualified success endpoint rates. Secondary outcomes: visual acuity (VA), mean deviation (MD), bleb evaluation, according to Moorfields Bleb Grading System (MBGS); spectral domain OCT (SD-OCT) bleb examination;…
European study of the efficacy of a cross-linked gel stent for the treatment of glaucoma
2020
indexation en cours.; PURPOSE: This study investigated the efficacy and safety of a cross-linked collagen stent (XEN 45) with or without cataract surgery in the treatment of glaucoma. SETTING: Real-life setting. DESIGN: Prospective, open-label, multicenter clinical trial. METHODS: Eligible patients with glaucoma inadequately controlled by treatment, or poor compliance or intolerance to topical therapy were included. Patients were divided into those with implant only (solo group; phakic and pseudophakic patients) and implant combined with cataract surgery (combo group). Differences in average intraocular pressure (IOP) and number of medications between baseline and study end (12 months), and…