Search results for "implants"
showing 10 items of 505 documents
Validation of a Portuguese version of the Groningen radiotherapy-induced xerostomia questionnaire
2022
The aim of this study was to validate and determine at pretest level the reliability of the Portuguese version of the Groningen radiotherapy-induced xerostomia questionnaire. This study employed 37 head and neck cancer patients. Each patient signed an informed consent and responded to the Portuguese version of the questionnaire in the form of an interview. This was repeated again after 2 weeks. A standard single question provided a validity check. Data were analyzed using Cronbach?s ? to test its reliability and total and interitem correlation, and intraclass correlation to determine its internal consistency and test-retest reliability. Construct validity supported by objective measurements…
Analogical and Digital Workflow in the Design and Preparation of the Emergence Profile of Biologically Oriented Preparation Technique (BOPT) Crowns o…
2019
: The Biologically Oriented Preparation Technique (BOPT), developed by Ignacio Loi and published in 2008, is a consolidated concept in the modeling and preservation of pericoronal soft tissues. The present study describes the analogical and digital methods allowing adequate design and preparation of the emergence profile of BOPT crowns in the working model, with a view to comparing the workflow and advantages of each method. At present, not all the digital procedures have been fully optimized to completely replace the traditional analogical methods. Nevertheless, it is only a matter of time until dental digitalization technology totally replaces the analogical clinical methods. The digital …
Rehabilitation of severely resorbed maxillae with zygomatic implants: An update
2007
Studies highlight the zygomatic bone as a suitable anatomical structure for implant placements since they cross four corticals. Zygomatic implants were described by Branemark in 1998, since then zygomatic implants are indicated in maxillae with atrophy of the posterior area. They have been used in systemic diseases associated with bone loss in this area, and in patients who have suffered radical surgery for maxillofacial tumors. Computed tomography is recommended before placement in order to discount any pathology of the maxillary sinus. The surgical technique has been slightly modified since its description with procedures such as the sinus slot technique. The success rate obtained by diff…
Sinus elevation by in situ utilization of bone scrapers : technique and results
2007
Objectives: The objective was to present a novel technique for antrostomy performed before sinus elevation in atrophic maxilla for subsequent implant placement. Material and methods: The study included 10 sinus elevations performed by the proposed technique in nine consecutive patients presenting with inadequate posterior maxillary height. The technique is described, calculating the antrostomy surface area, volume of bone tissue obtained and final height attained in each case. A total of 16 implants were placed. Results: All ten elevations were accomplished. Mean antrostomy surface area was 0.55 mm2 , mean bone volume obtained was 0.56 cm3 and mean height attained was 11.7 mm from a baselin…
Systemic risk factors for peri-implant bone loss: a systematic review and meta-analysis
2014
The aim of this study was to determine the influence of patient-related systemic risk factors (systemic disease, genetic traits, chronic drug or alcohol consumption, and smoking status) on peri-implant bone loss at least 1 year after implant installation and prosthetic loading. An electronic search was performed of MEDLINE, EMBASE, and The Cochrane Central Register of Controlled Trials up to January 2012. One thousand seven hundred and sixty-three studies were identified. After applying a three-stage screening process, 17 articles were included in the qualitative analysis, but only 13 in the quantitative analysis, since smoking was a common exposure. The meta-analysis of these 13 studies (4…
Barbed Dental Ti6Al4V Alloy Screw : Design and Bench Testing
2023
Background context. Dental implants are designed to replace a missing tooth. Implant stability is vital to achieving osseointegration and successful implantation. Although there are many implants available on the market, there is room for improvement. Purpose. We describe a new dental implant with improved primary stability features. Study design. Lab bench test studies. Methods. We evaluated the new implant using static and flexion–compression fatigue tests with compression loads, 35 Ncm tightening torque, displacement control, 0.01 mm/s actuator movement speed, and 9–10 Hz load application frequency, obtaining a cyclic load diagram. We applied variable cyclic loadings of prede…
Patient-centered outcomes after surgical treatment of peri-implantitis: a prospective clinical study.
2022
Background: Peri-implantitis is an inflammatory process affecting soft and hard tissues surrounding dental implants, causing progressive marginal bone loss. Peri-implant surgery is the treatment of choice. However, evidence about its impact on patients' quality of life (QoL) is limited. This study aimed to assess pain and QoL in the first seven post-operative days and measure patient satisfaction at the end of this period. Material and methods: A prospective cohort study was conducted in patients with peri-implantitis. Patients reported pain on a visual analogue scale (VAS) ranging from 0 to 100mm every day during the first week after surgery. They then completed the OHIP-14sp questionnaire…
Current characterisation for ultra low power wireless body area networks
2010
The emerging area of body area networks (BAN) imposes challenging requirements on hardware and software to achieve the desired lifetimes for certain devices such as long term medical implants. In this paper, we propose a novel approach to the measurement and characterisation of the energy consumption of BAN devices. The approach uses a low cost energy auditing circuit and addresses the problem of accurately measuring low-level current consumption. This new technique will allow precise and analytical measurements of systems and components in terms of energy. This will help circuit designers minimise power consumption in BAN devices. Software engineers might use this approach to validate and …
Immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associat…
2019
Background The aim of the present study was to radiographically evaluate the vertical socket walls changes, and the peri-implant marginal bone remodelling, and clinicallly the soft tissues conditions around the non-submerged single implants placed into the inter radicular septum of mandibular molar sockets, associated with a collagen membrane, after 3 years of loading. Material and Methods Thirty patients underwent to placement of a non-submerged implants with a laser-microtextured collar into the inter radicular septum of mandibular molar fresh extraction sockets. A collagen membrane and the mucoperiosteal flap were adapted around the neck of the implants, leaving the laser-microtextured c…
Evaluación de 80 implantes, sometidos a carga inmediata en desdentados inferiores tras un seguimiento de dos años
2006
Objetivo: Analizar el comportamiento tanto clínico como radiológico de ochentas implantes con una nueva superficie tratada mediante una disolución de ácido sulfúrico y fluorhídrico con posterior tratamiento térmico, que han sido sometidos a carga inmediata en pacientes rehabilitados con sobredentaduras inferiores. Diseño del artículo: Estudio observacional, prospectivo en 20 pacientes rehabilitados con sobredentaduras inferiores, soportadas sobre cuatro implantes de 13 milímetros de longitud. Todos los pacientes fueron planificados e incluídos tras el consentimiento, anamnesis, exploración clínica y estudio radiográfico y mediante montaje clínico previo de la prótesis inferior. Resultados: …