Search results for "imulation"
showing 10 items of 7271 documents
Key issues in decomposing fMRI during naturalistic and continuous music experience with independent component analysis
2014
Background: Independent component analysis (ICA) has been often used to decompose fMRI data mostly for the resting-state, block and event-related designs due to its outstanding advantage. For fMRI data during free-listening experiences, only a few exploratory studies applied ICA.New method: For processing the fMRI data elicited by 512-s modern tango, a FFT based band-pass filter was used to further pre-process the fMRI data to remove sources of no interest and noise. Then, a fast model order selection method was applied to estimate the number of sources. Next, both individual ICA and group ICA were performed. Subsequently, ICA components whose temporal courses were significantly correlated …
Tracking the corticospinal responses to strength training
2020
Purpose\ud The motor cortex (M1) appears to be a primary site of adaptation following both a single session, and repeated strength-training sessions across multiple weeks. Given that a single session of strength-training is sufficient to induce modification at the level of the M1 and corticospinal tract, this study sought to determine how these acute changes in M1 and corticospinal tract might accumulate across the course of a 2-week heavy-load strength-training program.\ud \ud Methods\ud Transcranial magnetic stimulation (TMS) was used to infer corticospinal excitability (CSE), intracortical facilitation (ICF), short and long-interval intracortical inhibition (SICI and LICI) and silent per…
Postactivation potentiation can counteract declines in force and power that occur after stretching.
2016
Stretching can decrease a muscle's maximal force, whereas short but intense muscle contractions can increase it. We hypothesized that when combined, postactivation potentiation induced by reactive jumps would counteract stretch-induced decrements in drop jump (DJ) performance. Moreover, we measured changes in muscle twitch forces and ankle joint stiffness (KAnkle ) to examine underlying mechanisms. Twenty subjects completed three DJs and 10 electrically evoked muscle twitches of the triceps surae subsequent to four different conditioning activities and control. The conditioning activities were 10 hops, 20s of static stretching of the triceps surae muscle, 20s of stretching followed by 10 ho…
Estimation of Muscular Fatigue under Electromyostimulation Using CWT
2012
International audience; The aims of this study are to investigate muscular fatigue and to propose a new fatigue index based on the continuous wavelet transform (CWT) which is compared to the standard fatigue indexes from literature. Fatigue indexes are all based on the electrical activity of muscles (electromyogram) acquired during an electrically stimulated contraction thanks to two modules (electromyostimulation + electromyography recording) that can analyze EMG signals in real time during electromyostimulation. The extracted parameters are compared with each other and their sensitivity to noise is studied. The effect of truncation of M waves is then investigated, enlightening the robustn…
Different neuronal contribution to N20 somatosensory evoked potential and to CO2 laser evoked potentials: an intracerebral recording study
2004
Abstract Objective : To investigate the possible contribution of the primary somatosensory area (SI) to pain sensation. Methods : Depth recordings of CO 2 laser evoked potentials (LEPs) and somatosensory evoked potentials (SEPs) were performed in an epileptic patient with a stereotactically implanted electrode (Talairach coordinates y =−23, z =40) that passed about 10 mm below the hand representation in her left SI area, as assessed by the source of the N20 SEP component. Results : The intracerebral electrode was able to record the N20 SEP component after non-painful electrical stimulation of her right median nerve. The N20 potential showed a phase reversal in the bipolar montage (at about …
Light scattering in artificial fog and simulated with light scattering filter.
2009
Disability glare, affecting e.g. road safety at night, may result either from intraocular light scattering or from external conditions such as fog. Measurements were made of light scattering in fog and compared with intraocular straylight data for normal eyes and eyes with simulated cataract. All measurements were made with a direct compensation flicker method. To estimate light scattering levels in fog, straylight measurements were carried in a fog chamber for different densities of fog. Density was characterized by the meteorological term visibility V and ranged from 7 to 25. Test distance for measurements in the fog was constant at 5 m. Cataract eye conditions were simulated by placing a…
Uncertainty quantification in simulations of epidemics using polynomial chaos.
2012
Mathematical models based on ordinary differential equations are a useful tool to study the processes involved in epidemiology. Many models consider that the parameters are deterministic variables. But in practice, the transmission parameters present large variability and it is not possible to determine them exactly, and it is necessary to introduce randomness. In this paper, we present an application of the polynomial chaos approach to epidemiological mathematical models based on ordinary differential equations with random coefficients. Taking into account the variability of the transmission parameters of the model, this approach allows us to obtain an auxiliary system of differential equa…
Facilitated neurogenic inflammation in unaffected limbs of patients with complex regional pain syndrome.
2003
Pain, edema, increased skin temperature, reddening and trophic changes characterize complex regional pain syndrome (CRPS). Recently, we have been able to show facilitated neurogenic inflammation on the affected limb. In the current study unaffected limbs were examined after resolution of the CRPS symptoms to assess possible generalized changes predisposing to CRPS. In 12 patients and in 12 healthy volunteers dermal microdialysis in combination with electrical C-fiber stimulation was employed to induce neuropeptide release. Dialysate protein concentration and axon reflex vasodilation were measured. Neither in patients nor in controls did electrical stimulation lead to protein extravasation, …
Optical and Visual Quality of the Visian Implantable Collamer Lens Using an Adaptive-Optics Visual Simulator
2013
To evaluate visual and optical quality of the implantable collamer lens for different powers and sizes of incision surgery.Prospective study in humans.An adaptive optics visual simulator was used to measure 3 powers of implantable collamer lenses and simulate the implantable collamer lens wavefront aberration's pattern for small- and large-incision surgery. Visual acuity (VA) and contrast sensitivity were measured in 11 observers for 3- and 5-mm pupils. Modulation transfer function, point spread function, and Strehl ratio were calculated.At 3 mm pupil, no statistically significant differences were found between both incision sizes for any implantable collamer lens power, except for -15 diop…
Testing Frequency-Domain Causality in Multivariate Time Series
2010
We introduce a new hypothesis-testing framework, based on surrogate data generation, to assess in the frequency domain, the concept of causality among multivariate (MV) time series. The approach extends the traditional Fourier transform (FT) method for generating surrogate data in a MV process and adapts it to the specific issue of causality. It generates causal FT (CFT) surrogates with FT modulus taken from the original series, and FT phase taken from a set of series with causal interactions set to zero over the direction of interest and preserved over all other directions. Two different zero-setting procedures, acting on the parameters of a MV autoregressive (MVAR) model fitted on the ori…