Search results for "ion source"
showing 10 items of 337 documents
The effect of plasma electrode collar structure on the performance of the JYFL 14GHz electron cyclotron resonance ion source
2013
Abstract The influence of a so-called collar structure on the performance of the JYFL 14 GHz electron cyclotron resonance ion source (ECRIS) has been studied experimentally at the Department of Physics, University of Jyvaskyla (JYFL). The collar is a cylindrical structure extruding inwards from the plasma electrode. The collar length was varied between 5 and 60 mm. For some ion species a moderate performance improvement was achieved in terms of extracted beam current and transverse emittance up to 30 mm collar length. Longer collars resulted in a substantial performance decrease. Different collar materials, i.e. nonmagnetic stainless steel, aluminum and Al 2 O 3 , and a wide range of ion sp…
Broadband microwave emission spectrum associated with kinetic instabilities in minimum-B ECR plasmas
2017
Plasmas of electron cyclotron resonance ion sources (ECRISs) are prone to kinetic instabilities due to the resonant heating mechanism resulting in anisotropic electron velocity distribution. Frequently observed periodic oscillations of extracted ion beam current in the case of high plasma heating power and/or strong magnetic field have been proven to be caused by cyclotrontype instabilities leading to a notable reduction and temporal variation of highly charged ion production. Thus, investigations of such instabilities and techniques for their suppression have become important topics in ECRIS research. The microwave emission caused by the instabilities contains information on the electron e…
Time resolved measurements of hydrogen ion energy distributions in a pulsed 2.45 GHz microwave plasma
2017
A plasma diagnostic study of the Ion Energy Distribution Functions (IEDFs) of H+, H+2H2+, and H+3H3+ ions in a 2.45 GHz hydrogen plasma reactor called TIPS is presented. The measurements are conducted by using a Plasma Ion Mass Spectrometer with an energy sector and a quadrupole detector from HIDEN Analytical Limited in order to select an ion species and to measure its energy distribution. The reactor is operated in the pulsed mode at 100 Hz with a duty cycle of 10% (1 ms pulse width). The IEDFs of H+, H+2H2+, and H+3H3+ are obtained each 5 μs with 1 μs time resolution throughout the entire pulse. The temporal evolution of the plasma potential and ion temperature of H+ is derived from the d…
High efficiency resonance ionization of palladium with Ti:sapphire lasers
2016
This work presents the development and testing of highly efficient excitation schemes for resonance ionization of palladium. To achieve the highest ionization efficiencies, a high-power, high repetition rate Ti:sapphire laser system was used and 2-step, 3-step and 4-step schemes were investigated and compared. Starting from different excited steps, the frequencies of the final ionization steps were tuned across the full accessible spectral range of the laser system, revealing several autoionizing Rydberg series, which converge towards the energetically higher lying state of the Pd+ ion ground state configuration. Through proper choice of these excitation steps, we developed a highly efficie…
Measurements of the energy distribution of electrons lost from the minimum B-field -- the effect of instabilities and two-frequency heating
2020
Further progress in the development of ECR ion sources (ECRIS) requires deeper understanding of the underlying physics. One of the topics that remains obscure, though being crucial for the performance of the ECRIS, is the electron energy distribution (EED). A well-developed technique of measuring the EED of electrons escaping axially from the magnetically confined plasma of an ECRIS was used for the study of EED in unstable mode of plasma confinement, i.e. in the presence of kinetic instabilities. The experimental data were recorded for pulsed and CW discharges with a room-temperature 14 GHz ECRIS at the JYFL accelerator laboratory. The measurements were focused on observing differences bet…
Charge breeding at GANIL: Improvements, results, and comparison with the other facilities
2019
International audience; The 1+/n+ method, based on an ECRIS charge breeder (CB) originally developed at the LPSC laboratory, is now implemented at GANIL for the production of Radioactive Ion Beams (RIBs). Prior to its installation in the middle of the low energy beam line of the SPIRAL1 facility, the 1+/n+ system CB has been modified based on the experiments performed on the CARIBU Facility at Argone National Laboratory. Later, it has been tested at the 1+/n+ LPSC test bench to validate its operation performances. Charge breeding efficiencies as well as charge breeding times have been measured for noble gases and alkali elements. The commissioning phase started at GANIL in the second half-y…
Hydrogen plasma induced photoelectron emission from low work function cesium covered metal surfaces
2017
Experimental results of hydrogen plasma induced photoelectron emission from cesium covered metal surfaces under ion source relevant conditions are reported. The transient photoelectron current during the Cs deposition process is measured from Mo, Al, Cu, Ta, Y, Ni, and stainless steel (SAE 304) surfaces. The photoelectron emission is 2–3.5 times higher at optimal Cs layer thickness in comparison to the clean substrate material. Emission from the thick layer of Cs is found to be 60%–80% lower than the emission from clean substrates. peerReviewed
Cyclotron instability in the afterglow mode of minimum-B ECRIS.
2016
It was shown recently that cyclotron instability in non-equilibrium plasma of a minimum-B electron cyclotron resonance ion source (ECRIS) causes perturbation of the extracted ion current and generation of strong bursts of bremsstrahlung emission, which limit the performance of the ion source. The present work is devoted to the dynamic regimes of plasma instability in ECRIS operated in pulsed mode. Instability develops in decaying plasma shortly after heating microwaves are switched off and manifests itself in the form of powerful pulses of electromagnetic emission associated with precipitation of high energy electrons. Time-resolved measurements of microwave emission bursts are presented. I…
Lead evaporation instabilities and failure mechanisms of the micro oven at the GTS-LHC ECR ion source at CERN
2020
The GTS-LHC ECR ion source (named after the Grenoble Test Source and the Large Hadron Collider) at CERN provides heavy ion beams for the chain of accelerators from Linac3 up to the LHC for high energy collision experiments and to the Super Proton Synchrotron for fixed target experiments. During the standard operation, the oven technique is used to evaporate lead into the source plasma to produce multiple charged lead ion beams. Intensity and stability are key parameters for the beam, and the operational experience is that some of the source instabilities can be linked to the oven performance. Over long operation periods of several weeks, the evaporation is not stable which makes the tuning …
Gasdynamic ECR ion source for negative ion production
2018
H− ion sources are needed in various areas of accelerator technology, such as beam injection into cyclotrons and storage rings and as a part of neutral beam injectors for plasma heating in experimental facilities studying thermonuclear fusion. It was recently demonstrated that gasdynamic ion source based on ECR discharge in a simple mirror trap is very efficient for proton beam production [1]. Here we use the gasdynamic plasma source as the first stage driver of volumetric negative ion production through dissociative electron attachment (DEA) [2]. Experiments were performed with a pulsed 37 GHz / up to 100 kW gyrotron radiation in a dual-trap magnetic system, which consists of two identical…