Search results for "ion source"
showing 10 items of 337 documents
Direct analysis in real-time high-resolution mass spectrometry as a valuable tool for polyphenols profiling in olive oil
2018
A fast and reliable method to characterize the polyphenolic compound profiles in extra virgin olive oil (EVOO) has been developed using direct analysis in real time (DART) and linear ion-trap Orbitrap mass spectrometry (LTQ-Orbitrap-MS). Hydroalcoholic extraction increased speed and reduced matrix effects, and DART-MS/MS ensured accurate analysis. Characterization of polyphenol fingerprinting in EVOO samples takes 2 min. This method exhibited proper linearity (R2 ≥ 0.99) in the range of 5–2500 μg g−1, limit of detection (LOD) of 1.5 μg g−1 (signal-to noise S/N = 3), and limits of quantitation (LOQs) of 5 μg g−1 (S/N = 10) for resveratrol (a polyphenol not detected in olive oil). Six spiked …
Interaction risk with proton pump inhibitors in general practice: significant disagreement between different drug-related information sources.
2006
Aims To compare information on drug–drug interactions (DDIs) reported on two standard drug-related information sources (Summary of Product Characteristics and Drugdex system by Micromedex), by assessing the prevalence and predictors of potential DDI with proton pump inhibitors (PPIs) in general practice. Methods From the ‘Caserta-1’ Local Health-Service database, 156 general practitioners (GPs) were recruited. From more than 180 000 individuals registered on their lists, we selected patients receiving co-prescription of PPI and medications at interaction risk, according to the Italian Summary of Product Characteristics (SPC) of PPI and Drugdex information, during the year 2003. Thereafter, …
An efficient excitation scheme for resonance ionization of tin in a laser ion source
1992
An efficient three-colour, three-step resonant excitation/ionization scheme has been found for tin that leads from the 5p23P2 level of the ground-state multiplet via two excited atomic levels (λ1 = 317.51 nm and λ2 = 811.40 nm) to an autoionizing state 9s3P2(λ3 = 823.49 nm) at 59375.9 cm−1. This excitation path permits the saturation of all transitions with the limited power available from a copper vapour laser pumped dye laser system (Esat ≈ 1.5 mJcm2 for λ3). The high repetition rate of such a laser system is essential for a highly efficient laser ion source.
Studies of plasma breakdown and electron heating on a 14 GHz ECR ion source through measurement of plasma bremsstrahlung
2011
Temporal evolution of plasma bremsstrahlung emitted by a 14?GHz electron cyclotron resonance ion source (ECRIS) operated in pulsed mode is presented in the energy range 1.5?400?keV with 100??s resolution. Such a high temporal resolution together with this energy range has never been measured before with an ECRIS. Data are presented as a function of microwave power, neutral gas pressure, magnetic field configuration and seed electron density. The saturation time of the bremsstrahlung count rate is almost independent of the photon energy up to 100?keV and exhibits similar characteristics with the neutral gas balance. The average photon energy during the plasma breakdown is significantly highe…
A software tool to acquire, synchronise and playback multimedia data: an application in kinesiology
2000
Assessing the physical condition of the human body frequently requires evaluating different tests performed by different devices. This information has to be analysed simultaneously to derive conclusions, and so a temporal relationship must be established between the data sources. In this paper, synchronisation of the sources of information is achieved by synchronising the clocks of computers connected in a Local Area Network. A clock synchronisation protocol is used and a global time is stamped in each information data flow. During analysis, the time-stamp is used to playback the data in a synchronised way. The proposed system is valid for any medical application in which data synchronisati…
Nanoelectrospray with ion-trap mass spectrometry for the determination of beta-casomorphins in derived milk products.
2009
Beta-casomorphins (b-CMs) are bioactive peptides derived from casein with opioid agonist effects similar to morphine. The use of electrospray (ESI) with quadrupole ion-trap mass spectrometry (QIT-MS) for these compounds in two matrices, cheese and milk, was examined. It was compared to a liquid chromatography (LC) coupled to mass spectrometry (LC-MS), and a "soft" ionisation technique, NanoMate, with selected ion monitoring (SIM), which are unreliable for the determination of trace casomorphins in derived milk products. b-CM mass fragmentation pathways were done for the four most common b-CMs: beta-casomorphin (1-5) bovine (b-CM-5), beta-casomorphin (1-7) bovine (b-CM-7), [D-Ala2, D-Pro4,Ty…
Clinical microbeam radiation therapy with a compact source: specifications of the line-focus X-ray tube
2020
Highlights • Line-focus X-ray tubes are suitable for clinical microbeam radiation therapy (MRT). • A modular high-voltage supply safely enables high electron beam powers. • An electron accelerator was designed to generate an eccentric focal spot. • We simulated a peak-to-valley dose ratio above 20 for single-field MRT. • Microbeam arc therapy spares healthy brain tissue compared to single-field MRT.
Performance of the on-line isotope separation facility HELIOS at the Mainz reactor
1981
Abstract The helium-jet on-line isotope eparation facility HELIOS is in operation at the Mainz reactor for spectroscopic studies on mass separated neutron-rich nuclides far from the line of beta-stability. The basic features and achievements of the facility are reported. A total of 45 isotopes of the elements Rb, Sr, Y, Sn, Sb, Te, Cs, Ba, La, Ce, Pr and Nd have been separated and identified so far. Overall efficiencies up to 2% have been obtained using the integrated skimmer ion source arrangement either in a hollow cathode or in a high temperature surface ionization mode. The delay time for the HELIOS system was determined to be about 1 s.
Information sources used for vacation tourists in tourist destinations
2012
En esta investigación se analiza el uso de las fuentes de información y su incidencia en distintas etapas del proceso de decisión, incidiendo en la búsqueda de información realizada por los turistas en destino. Los resultados muestran que tanto el número y tipo de fuentes de información utilizadas, así como la intensidad de la búsqueda y las decisiones tomadas en destino, es muy diferente del que realizan los turistas antes de llegar a su destino vacacional. Basados en los resultados, como parte de las conclusiones, se exponen ciertas directrices de interés para la gestión empresarial, en relación a la utilización de fuentes de información en los destinos turísticos. This research examines …
Strukturuntersuchung von polyestern durch direkten abbau im massenspektrometer, 3. Poly-β-propiolacton, poly-β-pivalolacton und poly-δ-valerolacton
1978
Poly(oxycarbonylethylene) (poly-β-propiolactone), poly(oxycarbonyl-1,1-dimeothylethylene) (poly-β-pivalolactone), and poly(oxycarbonyltetramethylene) (poly-δ-valerolactone) were pyrolyzed directly in the ion source of a mass spectrometer and their thermal and electron impact induced degradation mechanisms are established. Poly-β-propiolactone is thermally degraded by rupture of the OCH2-bond by a cis elimination to give carboxyl and acryloyl endgroups, whereas poly-δ-valerolactone depolymerizes to δ-valerolactone. Poly-β-pivalolactone degrades thermally to cyclic oligomers of pivalolactone, which could be proved by a separated pyrolysis and IR-spectroscopy and gel chromatography.