Search results for "ionization-time"

showing 2 items of 2 documents

Optimization of the preanalytical steps of matrix-assisted laser desorption ionization-time of flight mass spectrometry identification provides a fle…

2012

ABSTRACT We report here that modifications of the preanalytical steps of matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) identification of yeasts, with regard to the original protocol provided by the manufacturers, appear to be efficient for the reliable routine identification of clinical yeast isolates in medical laboratories. Indeed, when one colony was sampled instead of five and the protein extraction protocol was modified, the performance of MALDI-TOF MS was superior to that of the API ID 32C method (discrepancies were confirmed by using molecular identification), allowing the correct identification of 94% of the 335 clinical isolates prospec…

Microbiology (medical)Microbiological TechniquesTime Factorsmedical laboratories[SDV]Life Sciences [q-bio]clinical yeast isolatesMatrix assisted laser desorption ionization time of flightMycologyMass spectrometrySpecimen Handlingflight mass spectrometry03 medical and health sciencesYeastsHumansionization-time030304 developmental biologyMolecular identification0303 health sciencesChromatography030306 microbiologyChemistryYeastCulture MediaIdentification (information)Mycosesmatrix-assisted laserSpectrometry Mass Matrix-Assisted Laser Desorption-Ionization[SDE]Environmental SciencesidentificationJournal of clinical microbiology
researchProduct

Assessing the MALDI-TOF MS sample preparation procedure to analyze the influence of thermo-oxidative ageing and thermo-mechanical degradation on poly…

2011

[EN] Multiple processing by means of successive injection cycles was used to simulate the thermo-mechanical degradation effects on the oligomeric distribution of PLA under mechanical recycling. Likewise, an accelerated thermal ageing over PLA glass transition was performed in order to simulate its service life. MALDI-TOF MS was used for the analysis and the sample preparation procedure was assessed by means of a statistical Design of Experiments (DoE). The quality effects in use for the analysis were signal-to-noise ratio and Resolution. Different matrixes, analyte/matrix proportions and the use of NaTFA as cationization agent were considered. A deep inspection of the statistical results pr…

Solucions polimèriquesPolymers and PlasticsGeneral Physics and AstronomyTransesterificationsThermo-mechanical degradationSample preparation procedureMatrix (chemical analysis)DegradationMechanismsMaterials ChemistryCationizationMechanical recyclingSample preparationRepeating unitPoly(lactide)Signal to noise ratioChemistryMultiple processingDesign of Experiments (DoE)AnalytesInjection cyclesPolylactidesMAQUINAS Y MOTORES TERMICOSMatrix-assisted laser desorption/ionization-time-of-flight mass spectrometryGlass transitionDesign of experimentsGlass lasersThermo mechanicalMALDI TOF MSChromatographyMatrixMass spectrometrySignal to noiseTermoplàsticsOrganic ChemistryDegradation mechanismThermo-oxidative ageingStatistical design of experimentsMatrix-assisted laser desorption/ionizationInvestigation methodsMatrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS)Polylactide (PLA)AgeingOligomersDegradation (geology)DesorptionDeep inspectionExperimentsPoly(lactide)European Polymer Journal
researchProduct