Search results for "ionizing"

showing 9 items of 149 documents

Uncertainty on radiation doses estimated by biological and retrospective physical methods

2018

International audience; Biological and physical retrospective dosimetry are recognised as key techniques to provide individual estimates of dose following unplanned exposures to ionising radiation. Whilst there has been a relatively large amount of recent development in the biological and physical procedures, development of statistical analysis techniques has failed to keep pace. The aim of this paper is to review the current state of the art in uncertainty analysis techniques across the 'EURADOS Working Group 10- Retrospective dosimetry' members, to give concrete examples of implementation of the techniques recommended in the international standards, and to further promote the use of Monte…

medicine.medical_specialtyRadiology Nuclear Medicine and Imaging[SDV]Life Sciences [q-bio]Public Health and Health CareRadiation DosageRisk Assessment030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineRadiation MonitoringRadiation IonizingmedicineDosimetryHumansStatistical analysisMedical physicsRadiometryUncertainty analysisMathematicsRadiationRadiological and Ultrasound TechnologyPhysicsUncertaintyPublic Health Environmental and Occupational HealthGeneral Medicineretrospective dosimetry biodosimetry physical dosimetry uncertainityEuropeChemistryWork (electrical)030220 oncology & carcinogenesisRadiation monitoringBody BurdenRisk assessmentWhole bodyMathematicsHuman
researchProduct

The Role of Epidemiology in Cancer Risk Assessment of Nonionizing Radiation

2011

medicine.medical_specialtybusiness.industryCancer risk assessmentEpidemiologyMedicineMedical physicsbusinessNon-ionizing radiationCancer Risk Evaluation
researchProduct

O2-Loading Treatment of Ge-Doped Silica Fibers: A Radiation Hardening Process

2016

International audience; The effects of a high-pressure O2-loading treatment on the radiation response of Ge-doped optical fibers (OFs) were investigated. We found that the incorporation of high concentration of interstitial molecular oxygen remarkably enhances the resistance to ionizing radiation of Ge-doped OFs in the UV-Visible domain and, at the same time, improves the transmission of UV light in the unirradiated OF sample. By comparison with previously reported results, the O2-loading treatment turned out to increase the radiation resistance of Ge-doped OFs more efficiently than F or Ce codoping. The understanding of such amelioration relies in basic radiation-induced mechanisms that we…

optical fiberMaterials scienceAnalytical chemistrychemistry.chemical_elementGermanium02 engineering and technologygermanosilicate01 natural scienceslaw.inventionIonizing radiationOpticslaw0103 physical sciencesIrradiationElectron paramagnetic resonanceRadiation hardeningRadiation resistance[PHYS]Physics [physics]radiation effect010308 nuclear & particles physicsbusiness.industryDopingSettore FIS/01 - Fisica SperimentaleResonance021001 nanoscience & nanotechnologyAtomic and Molecular Physics and Opticschemistry0210 nano-technologybusiness
researchProduct

Investigation of Coating Impact on OFDR Optical Remote Fiber-Based Sensors Performances for Their Integration in High Temperature and Radiation Envir…

2016

The response of optical frequency-domain reflectometry-based temperature sensors is here investigated in harsh environments (high temperature, high radiation dose) focusing the attention on the impact of the fiber coating on the sensor performances in such conditions. Our results demonstrate that the various coating types evolve differently under thermal treatment and/or radiations, resulting in a small (<5%) change in the temperature coefficient of the sensor. The identified procedure, consisting of a prethermal treatment of the fiber at its maximum coating operating temperature, is here verified up to 150 °C for higherature acrylate and up to 300 °C for polyamide coating. This method allo…

optical fiberOptical fiberMaterials science02 engineering and technologyRadiationengineering.material01 natural sciencesTemperature measurementIonizing radiationlaw.inventionhigh temperature020210 optoelectronics & photonicsOpticsCoatinglaw0103 physical sciences0202 electrical engineering electronic engineering information engineeringTraitement du signal et de l'imageOFDROptical fibersReflectometryRadiation010308 nuclear & particles physicsbusiness.industryAttenuationHigh temperatureAtomic and Molecular Physics and OpticsradiationFiber optic sensorengineeringOptoelectronicsbusinessDTSJournal of Lightwave Technology
researchProduct

HMG-CoA reductase inhibitors (statins) as anticancer drugs (Review)

2005

Apart from their lipid lowering activity, HMG-CoA reductase inhibitors (statins) impair numerous cellular functions associated with metastasis, e.g. gene expression, angiogenesis, cell adhesion, cell motility and invasiveness. Furthermore, statins have impact on apoptotic cell death and modulate cellular susceptibility to cell killing by anticancer drugs and ionizing radiation. Part of the effects provoked by statins are due to the inhibition of the prenylation of low molecular weight GTPases, in particular Ras and Rho, which play key roles in signaling evoked by stimulation of cell surface receptors. C-terminal lipid modification of Ras/Rho GTPases is essential for their correct intracellu…

rho GTP-Binding ProteinsCancer ResearchCell DeathbiologyCell growthGTPaseCell killingOncologyBiochemistryPrenylationras GTPase-Activating ProteinsNeoplasmsRadiation IonizingHMG-CoA reductaseCell AdhesionCancer researchbiology.proteinHumansProtein prenylationHydroxymethylglutaryl-CoA Reductase InhibitorsNeoplasm MetastasisLipid modificationCell adhesionCell ProliferationInternational Journal of Oncology
researchProduct

Late Activation of Stress-activated Protein Kinases/c-Jun N-terminal Kinases Triggered by Cisplatin-induced DNA Damage in Repair-defective Cells

2011

Although stress-activated protein kinases/c-Jun N-terminal kinases (SAPK/JNK) are rapidly activated by genotoxins, the role of DNA damage in this response is not well defined. Here we show that the SEK1/MKK4-mediated dual phosphorylation of SAPK/JNK (Thr-183/Tyr-185) correlates with the level of cisplatin-DNA adducts at late times (16–24 h) after drug treatment in both human and mouse cells. Transfection of platinated plasmid DNA also caused SAPK/JNK activation. A defect in transcription-coupled nucleotide excision repair resting on a mutation in Cockayne syndrome group B protein promoted the late SAPK/JNK activation following cisplatin exposure. Signaling to SAPK/JNK was accompanied by act…

rho GTP-Binding ProteinsDNA RepairMAP Kinase Kinase 4DNA repairDNA damageDNA damage response; DNA repair; cisplatin-DNA adducts; SAPK/JNKp38 mitogen-activated protein kinasesAntineoplastic AgentsCell Cycle ProteinsAtaxia Telangiectasia Mutated ProteinsProtein Serine-Threonine KinasesDNA and ChromosomesBiologyBiochemistryAtaxia Telangiectasia Mutated ProteinsDNA AdductsMiceRadiation IonizingAnimalsHumansDNA Breaks Double-StrandedMolecular BiologyReplication protein ACells CulturedMice KnockoutKinaseTumor Suppressor ProteinsJNK Mitogen-Activated Protein KinasesCell BiologyMolecular biologyDNA-Binding ProteinsEnzyme Activationc-Jun N-terminal kinasesbiology.proteinCisplatinSignal TransductionNucleotide excision repairJournal of Biological Chemistry
researchProduct

Impact of Gamma Radiation on Dynamic R

2019

GaN high-electron-mobility transistors (HEMTs) are promising next-generation devices in the power electronics field which can coexist with silicon semiconductors, mainly in some radiation-intensive environments, such as power space converters, where high frequencies and voltages are also needed. Its wide band gap (WBG), large breakdown electric field, and thermal stability improve actual silicon performances. However, at the moment, GaN HEMT technology suffers from some reliability issues, one of the more relevant of which is the dynamic on-state resistance (RON_dyn) regarding power switching converter applications. In this study, we focused on the drain-to-source on-resistance (RDSON) char…

total ionizing dose (TID)high-electron-mobility transistor (HEMT)assurance testingradiation effectsgallium nitride (GaN)radiation hardnessArticleMaterials (Basel, Switzerland)
researchProduct

Excess electronic recoil events in XENON1T

2020

We report results from searches for new physics with low-energy electronic recoil data recorded with the XENON1T detector. With an exposure of 0.65 t-y and an unprecedentedly low background rate of $76\pm2$ events/(t y keV) between 1 and 30 keV, the data enables sensitive searches for solar axions, an enhanced neutrino magnetic moment, and bosonic dark matter. An excess over known backgrounds is observed at low energies and most prominent between 2 and 3 keV. The solar axion model has a 3.4$\sigma$ significance, and a 3D 90% confidence surface is reported for axion couplings to electrons, photons, and nucleons. This surface is inscribed in the cuboid defined by $g_{ae}<3.8 \times 10^{-12}$,…

xenon: targetaxionssolar axionmagnetic momentdimension: 3neutrino: solarPhysics beyond the Standard ModelSolar neutrinodark matter: direct detection01 natural sciences7. Clean energyHigh Energy Physics - ExperimentDark matter direct detection axionHigh Energy Physics - Experiment (hep-ex)neutrinoXENONHigh Energy Physics - Phenomenology (hep-ph)background: lowRecoilelectron: recoil[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]beta-raysParticle Physics Experimentscoupling: (axion 2electron)multi-purpose particle detectornuclear instrumentationComputingMilieux_MISCELLANEOUSinstrumentationPhysicsxenon: liquidboson: dark matteraxion 2nucleontritiumnew physics: search forsemileptonic decayboson: vectortensionneutrino: magnetic momentHigh Energy Physics - Phenomenologyaxion 2photonlow backgroundbosonNeutrinoionizing radiationNucleonAstrophysics - Cosmology and Nongalactic AstrophysicsCosmology and Nongalactic Astrophysics (astro-ph.CO)dark matter detectorelectronic recoilElectron captureXENON1T detectorDark matterlow-energy electronic recoil dataFOS: Physical sciences[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]dark matterNONuclear physicsPE2_2PE2_1tritium: semileptonic decay0103 physical sciencessolar axion modelsurface[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]axion: couplingPE2_4010306 general physicspseudoscalarAxiondark matter: vectordark matter XENON1T detector electronic recoilsolar neutrinodetectorDark Matter Axions Beta Decay Liquid Xenon TPC010308 nuclear & particles physicsaxion 2electroncoupling: (axion 2nucleon)dark matter: detectormodel: axionGran Sassometrology[PHYS.HPHE]Physics [physics]/High Energy Physics - Phenomenology [hep-ph]axionstellar constraintscoupling: (axion 2photon)High Energy Physics::Experimentparticle dark matterdirect detectionbeta decayaxion: solar[PHYS.ASTR]Physics [physics]/Astrophysics [astro-ph]experimental results
researchProduct

Hydrogels for Three-Dimensional Ionizing-Radiation Dosimetry

2021

Radiation-sensitive gels are among the most recent and promising developments for radiation therapy (RT) dosimetry. RT dosimetry has the twofold goal of ensuring the quality of the treatment and the radiation protection of the patient. Benchmark dosimetry for acceptance testing and commissioning of RT systems is still based on ionization chambers. However, even the smallest chambers cannot resolve the steep dose gradients of up to 30–50% per mm generated with the most advanced techniques. While a multitude of systems based, e.g., on luminescence, silicon diodes and radiochromic materials have been developed, they do not allow the truly continuous 3D dose measurements offered by radiation-se…

xylenol-orangeMaterials sciencePolymers and Plasticspoly-vinyl alcoholScienceDose profileBioengineeringGeneral. Including alchemyReviewRadiation01 natural sciences030218 nuclear medicine & medical imagingIonizing radiationBiomaterials03 medical and health sciencesMagnetic resonance imaging0302 clinical medicineQD1-650103 physical sciencesthree-dimensional dosimetryDosimetryIrradiationQD1-999QD146-197Optical tomography010308 nuclear & particles physicsbusiness.industryOrganic ChemistryQpolyacrylamide gelChemistrySpectrophotometryAbsorbed doseglutaraldehydeRadiation protectionLuminescencebusinessInorganic chemistryBiomedical engineeringferrous sulfateGels
researchProduct