Search results for "kalibrointi"

showing 9 items of 9 documents

A Multi-Position Calibration Method for Consumer-Grade Accelerometers, Gyroscopes, and Magnetometers to Field Conditions

2017

This paper presents a calibration method for consumer-grade accelerometers, gyroscopes, and magnetometers. Considering the calibration of consumer-grade sensors, it is essential that no specialized equipment is required to create reference signals. In addition, the less is required from the reference signals, the more suitable the method is on the field. In the proposed method, the novelty in the calibration of the gyroscopes lies in the exploitation of only the known net rotations between the positions in a multi-position calibration. For accelerometers and magnetometers, the innovation is that the direction of reference signals, the gravity and the magnetic field of the Earth, are estimat…

EngineeringaccelerometersField (physics)painovoimaCalibration (statistics)Magnetometermagneettiset anturitgyroscopesgyroskoopitAccelerometer01 natural scienceskalibrointilaw.invention010309 opticslawPosition (vector)Inertial measurement unit0103 physical scienceskiihtyvyysanturitElectrical and Electronic EngineeringInstrumentationRemote sensingta213business.industry213 Electronic automation and communications engineering electronics010401 analytical chemistryAstrophysics::Instrumentation and Methods for AstrophysicsGyroscopemagnetometerscalibrationgravity0104 chemical sciencesEarth's magnetic fieldbusinessmagnetic sensorsIEEE Sensors Journal
researchProduct

A nonlinear mixed model approach to predict energy expenditure from heart rate.

2021

Abstract Objective. Heart rate (HR) monitoring provides a convenient and inexpensive way to predict energy expenditure (EE) during physical activity. However, there is a lot of variation among individuals in the EE-HR relationship, which should be taken into account in predictions. The objective is to develop a model that allows the prediction of EE based on HR as accurately as possible and allows an improvement of the prediction using calibration measurements from the target individual. Approach. We propose a nonlinear (logistic) mixed model for EE and HR measurements and an approach to calibrate the model for a new person who does not belong to the dataset used to estimate the model. The …

Mixed modelsykePhysiologyComputer science0206 medical engineeringindividual calibrationBiomedical EngineeringBiophysicsPhysical activityphysical activityheart rate monitoringModel parameters02 engineering and technologykalibrointilogistinen sekamallisykemittaus [energiankulutus]03 medical and health sciences0302 clinical medicineHeart RatePhysiology (medical)energy expenditureCalibrationHumanslogistic mixed modeltilastolliset mallitExerciseMonitoring PhysiologicHeterogeneous groupPrediction interval020601 biomedical engineeringmittausmenetelmätNonlinear systemEnergy expenditureExercise TestsykemittaritEnergy Metabolismfyysinen aktiivisuus.Algorithmfyysinen aktiivisuusenergiankulutus (aineenvaihdunta)030217 neurology & neurosurgeryPhysiological measurement
researchProduct

Calibration strategy of the JUNO experiment

2021

We present the calibration strategy for the 20 kton liquid scintillator central detector of the Jiangmen Underground Neutrino Observatory (JUNO). By utilizing a comprehensive multiple-source and multiple-positional calibration program, in combination with a novel dual calorimetry technique exploiting two independent photosensors and readout systems, we demonstrate that the JUNO central detector can achieve a better than 1% energy linearity and a 3% effective energy resolution, required by the neutrino mass ordering determination. peerReviewed

Physics::Instrumentation and DetectorsAstrophysics::Instrumentation and Methods for AstrophysicsneutriinotHigh Energy Physics::Experimentfysiikkakalibrointi
researchProduct

Calibration of the muon barrel chambers for the EMMA experiment

2017

The topic of this thesis was position calibration of muon barrel chambers used in the EMMA experiment. A detector ergo plank consist of seven chambers, and there were six uncalibrated detectors. The planks were set in a calibration stack, where there were four reference planks and six uncalibrated planks. Every chamber was divided into channels, and for every chamber, there was a specific position in the chamber. The position for each channel was ascertained by using manually calibrated reference planks and atmospheric muons. The calibration table was created for every chamber to obtain corresponding position for every channel in the chamber. The data collection was being done for approxima…

ajautumiskammiokosminen säteilykalibrointi
researchProduct

Autonomous hyperspectral UAS photogrammetry for environmental monitoring applications

2014

Abstract. The unmanned airborne system (UAS) remote sensing using lightweight multi- and hyperspectral imaging sensors offer new possibilities for the environmental monitoring applications. Based on the accurate measurements of the way in which the object reflect and emit energy, wide range of affecting variables can be monitored. Condition for reliable applications is reliable and accurate input data. In many applications, installation of geometric and radiometric reference targets in the object area is challenging, for instance, in forest or water areas. On the other hand, UASs are often operated in very poor conditions, under clouds or under variable cloud cover. Our objective is to deve…

lcsh:Applied optics. PhotonicsgeometryPoint cloudradiometryphotogrammetrylcsh:Technologykalibrointiremote sensingEnvironmental monitoringRemote sensingBlock (data storage)fotogrammetriaData processingblockForest inventorylcsh:Tlcsh:TA1501-1820Hyperspectral imagingcalibrationGeographyPhotogrammetryhyperspectrallcsh:TA1-2040Precision agriculturekaukokartoitusgeometriaUASlcsh:Engineering (General). Civil engineering (General)point cloud
researchProduct

Measurements of Low-Energy Protons using a Silicon Detector for Application to SEE Testing

2021

A silicon detector with a fast electronics chain is used for the dosimetry of protons in the range 0.5-5 MeV at the Centro Nacional de Aceleradores (CNA) 3 MV Tandem laboratory in Seville, Spain. In this configuration, measurements can be performed in pulsed mode, using a digitizer to record event-by-event proton energy depositions. The distributions of deposited energy were obtained thanks to a calibration with an alpha source. Measurements of flux and deposited energy are used to enable single event effect (SEE) testing on selected static random access memories (SRAMs).

protonitNuclear and High Energy PhysicspiiSilicon detectorMaterials sciencebusiness.industrySingle event effectskalibrointiLow energysäteilyfysiikkaNuclear Energy and EngineeringilmaisimetdosimetritOptoelectronicsSilicon detectorElectrical and Electronic EngineeringDetectors and Experimental TechniquesLow-energy protonsbusinessIEEE Transactions on Nuclear Science ( Volume: 69, Issue: 3, March 2022)
researchProduct

Remote Sensing of 3-D Geometry and Surface Moisture of a Peat Production Area Using Hyperspectral Frame Cameras in Visible to Short-Wave Infrared Spe…

2016

Miniaturized hyperspectral imaging sensors are becoming available to small unmanned airborne vehicle (UAV) platforms. Imaging concepts based on frame format offer an attractive alternative to conventional hyperspectral pushbroom scanners because they enable enhanced processing and interpretation potential by allowing for acquisition of the 3-D geometry of the object and multiple object views together with the hyperspectral reflectance signatures. The objective of this investigation was to study the performance of novel visible and near-infrared (VNIR) and short-wave infrared (SWIR) hyperspectral frame cameras based on a tunable Fabry–Pérot interferometer (FPI) in measuring a 3-D digital sur…

spectroscopygeometry010504 meteorology & atmospheric sciencesInfraredspektroskopiata11710211 other engineering and technologiesGeometryradiometry02 engineering and technologyremotely piloted aircraft01 natural scienceskalibrointiremote sensingCalibrationgeographic information systemComputer visionElectrical and Electronic Engineeringta218021101 geological & geomatics engineering0105 earth and related environmental sciencesRemote sensingta113ta213Contextual image classificationbusiness.industryHyperspectral imagingOtaNanocalibrationstereo visionVNIRInterferometryGeneral Earth and Planetary SciencesRGB color modelEnvironmental scienceRadiometrygeometriakaukokartoitusArtificial intelligencebusinessimage classificationIEEE Transactions on Geoscience and Remote Sensing
researchProduct

Tietokonetomografian annosmittaukset : kalibrointikäytännöt ja epävarmuudet

2015

Tietokonetomografiassa säteilyannoksen määrittämiseen käytettävät ionisaatiokammiot kalibroidaan tavallisimmin vapaasti ilmassa suhteessa ilmakermaan. Kalibrointikäytännöistä voi kuitenkin aiheutua epävarmuutta annoksen määrittämiseen fantomimittauksissa, sillä olosuhteet fantomissa ovat erilaiset kuin vapaasti ilmassa. Tässä työssä tutkittiin kalibrointikäytännöistä johtuvia epävarmuuksia annosmittauksissa. Työn kokeellisessa osassa mitattiin erään puikkomaisen ionisaatiokammion energiavaste ja näiden tulosten pohjalta mallinnettiin kammio Monte Carlo -menetelmällä tehtäviä simulaatioita varten. Kammion mallintamisen jälkeen simulaatioissa tutkittiin absor…

säteilyannoksetröntgensäteilydosimetrittietokonetomografiasäteilySäteilyturvakeskuskalibrointi
researchProduct

Kalibrointimittauslaitteiston suunnittelu ja valmistus värähtelyanturille

2009

värähtelytmittaritmittauslaitteetanturitkalibrointi
researchProduct