A Multi-Position Calibration Method for Consumer-Grade Accelerometers, Gyroscopes, and Magnetometers to Field Conditions
2017
This paper presents a calibration method for consumer-grade accelerometers, gyroscopes, and magnetometers. Considering the calibration of consumer-grade sensors, it is essential that no specialized equipment is required to create reference signals. In addition, the less is required from the reference signals, the more suitable the method is on the field. In the proposed method, the novelty in the calibration of the gyroscopes lies in the exploitation of only the known net rotations between the positions in a multi-position calibration. For accelerometers and magnetometers, the innovation is that the direction of reference signals, the gravity and the magnetic field of the Earth, are estimat…
A nonlinear mixed model approach to predict energy expenditure from heart rate.
2021
Abstract Objective. Heart rate (HR) monitoring provides a convenient and inexpensive way to predict energy expenditure (EE) during physical activity. However, there is a lot of variation among individuals in the EE-HR relationship, which should be taken into account in predictions. The objective is to develop a model that allows the prediction of EE based on HR as accurately as possible and allows an improvement of the prediction using calibration measurements from the target individual. Approach. We propose a nonlinear (logistic) mixed model for EE and HR measurements and an approach to calibrate the model for a new person who does not belong to the dataset used to estimate the model. The …
Calibration strategy of the JUNO experiment
2021
We present the calibration strategy for the 20 kton liquid scintillator central detector of the Jiangmen Underground Neutrino Observatory (JUNO). By utilizing a comprehensive multiple-source and multiple-positional calibration program, in combination with a novel dual calorimetry technique exploiting two independent photosensors and readout systems, we demonstrate that the JUNO central detector can achieve a better than 1% energy linearity and a 3% effective energy resolution, required by the neutrino mass ordering determination. peerReviewed
Calibration of the muon barrel chambers for the EMMA experiment
2017
The topic of this thesis was position calibration of muon barrel chambers used in the EMMA experiment. A detector ergo plank consist of seven chambers, and there were six uncalibrated detectors. The planks were set in a calibration stack, where there were four reference planks and six uncalibrated planks. Every chamber was divided into channels, and for every chamber, there was a specific position in the chamber. The position for each channel was ascertained by using manually calibrated reference planks and atmospheric muons. The calibration table was created for every chamber to obtain corresponding position for every channel in the chamber. The data collection was being done for approxima…
Autonomous hyperspectral UAS photogrammetry for environmental monitoring applications
2014
Abstract. The unmanned airborne system (UAS) remote sensing using lightweight multi- and hyperspectral imaging sensors offer new possibilities for the environmental monitoring applications. Based on the accurate measurements of the way in which the object reflect and emit energy, wide range of affecting variables can be monitored. Condition for reliable applications is reliable and accurate input data. In many applications, installation of geometric and radiometric reference targets in the object area is challenging, for instance, in forest or water areas. On the other hand, UASs are often operated in very poor conditions, under clouds or under variable cloud cover. Our objective is to deve…
Measurements of Low-Energy Protons using a Silicon Detector for Application to SEE Testing
2021
A silicon detector with a fast electronics chain is used for the dosimetry of protons in the range 0.5-5 MeV at the Centro Nacional de Aceleradores (CNA) 3 MV Tandem laboratory in Seville, Spain. In this configuration, measurements can be performed in pulsed mode, using a digitizer to record event-by-event proton energy depositions. The distributions of deposited energy were obtained thanks to a calibration with an alpha source. Measurements of flux and deposited energy are used to enable single event effect (SEE) testing on selected static random access memories (SRAMs).
Remote Sensing of 3-D Geometry and Surface Moisture of a Peat Production Area Using Hyperspectral Frame Cameras in Visible to Short-Wave Infrared Spe…
2016
Miniaturized hyperspectral imaging sensors are becoming available to small unmanned airborne vehicle (UAV) platforms. Imaging concepts based on frame format offer an attractive alternative to conventional hyperspectral pushbroom scanners because they enable enhanced processing and interpretation potential by allowing for acquisition of the 3-D geometry of the object and multiple object views together with the hyperspectral reflectance signatures. The objective of this investigation was to study the performance of novel visible and near-infrared (VNIR) and short-wave infrared (SWIR) hyperspectral frame cameras based on a tunable Fabry–Pérot interferometer (FPI) in measuring a 3-D digital sur…
Tietokonetomografian annosmittaukset : kalibrointikäytännöt ja epävarmuudet
2015
Tietokonetomografiassa säteilyannoksen määrittämiseen käytettävät ionisaatiokammiot kalibroidaan tavallisimmin vapaasti ilmassa suhteessa ilmakermaan. Kalibrointikäytännöistä voi kuitenkin aiheutua epävarmuutta annoksen määrittämiseen fantomimittauksissa, sillä olosuhteet fantomissa ovat erilaiset kuin vapaasti ilmassa. Tässä työssä tutkittiin kalibrointikäytännöistä johtuvia epävarmuuksia annosmittauksissa. Työn kokeellisessa osassa mitattiin erään puikkomaisen ionisaatiokammion energiavaste ja näiden tulosten pohjalta mallinnettiin kammio Monte Carlo -menetelmällä tehtäviä simulaatioita varten. Kammion mallintamisen jälkeen simulaatioissa tutkittiin absor…