Search results for "keratoplasty"
showing 8 items of 18 documents
Recurrent Granular Dystrophy of the Cornea
2006
Purpose: To describe a case of severe corneal granular dystrophy with clinicopathologic and molecular genetic findings. Methods: The DNAs of a 53-year-old male patient suffering from corneal granular dystrophy and nonaffected family members was analyzed by molecular genetic methods. Clinical features, and histopathologic and immunohistochemical findings from the penetrating keratoplasty specimen, are described. Results: Histopathologic and molecular genetic findings confirmed the diagnosis. A new genetic polymorphism is described. Histopathologic evidence supports the assumption of the epithelial origin of the described dystrophy. Conclusions: A severe course of corneal granular dystrophy c…
Favorable outcome in open globe injuries with low OTS score
2014
Purpose:.Open globe eye injuries can have profound social and economic consequences. Here, we describe two cases of war and outdoor activity open globe eye injury where, despite a low OTS score,.current microsurgical technology allowed for a favorable outcome.Case report 1: A 33-year-old Libyan soldier had been treated for an open-globe grenade blast trauma to his left eye, which showed light perception and OTS score 2..He had undergone a lensectomy and PPV with silicone oil tamponade. Surgical treatment included scleral buckling,.cornea trephination, tem-porary Eckardt keratoprosthesis, PPV revision, intraocular lens (IOL) implantation, and corneal grafting. Six months later, his VA was im…
Retinal Straylight Before and After Penetrating Keratoplasty in an Eye with a Post-Herpetic Corneal Scar
2008
Objetivo: Estudio in vivo de la luz dispersa que alcanza la retina en un paciente antes y despues de someterse a una queratoplastia penetrante (o sus siglas en ingles, PKP). Metodos: En un paciente varon de 65 anos con una ulcera corneal herpetica se midio la proporcion de luz dispersa que alcanza la retina tanto antes como despues de una PKP, utilizando para ello un metodo psicometrico denominado "de comparacion por compensacion" («Compensation comparison method», C-Quant straylightmeter, Oculus GmbH, Alemania). Resultados: La cantidad de luz dispersa que alcanza la retina medida antes de la cirugia fue elevada en comparacion con los valores obtenidos en estudios previos en sujetos normale…
Trasplante de córnea: aspectos bioéticos
2019
Resumen: Este trabajo aborda los aspectos bioéticos del trasplante de córnea, desde la donación y los tipos de la misma, incluyendo el comercio de órganos y tejidos, así como la metodología del trasplante y el uso de tratamientos inmunosupresores, además del consentimiento informado y la participación del paciente en las decisiones. Se analizan las técnicas actuales, la efectividad y las circunstancias en las que se puede aplicar cada una de ellas así como los estudios emergentes basados en la terapia celular. Algunos de los estudios emplean células troncales derivadas de embriones humanos, y otras de tejidos adultos y células troncales pluripotentes inducidas (iPS). Se propone un análisis …
Implantation of a custom intraocular lens with a 30-diopter torus for the correction of high astigmatism after penetrating keratoplasty.
2003
Abstract We present a 62-year-old woman who had implantation of an intraocular lens (IOL) with a torus of 30.0 diopters (D) in an eye after penetrating keratoplasty. The patient presented with cataract and a best corrected visual acuity of 20/400. Penetrating keratoplasty was performed in 1975 because of decompensated keratoconus. With a clear but inferiorly decentered corneal graft, visual acuity was limited because of keratoplasty-related high corneal astigmatism of 22.5@156 that could not be successfully treated with spectacles or contact lenses. A custom toric IOL with –30.0 D of cylindrical power was implanted in the capsular bag via a sclerocorneal tunnel incision. Additionally, a sph…
Irregularity of the posterior corneal surface during applanation using a curved femtosecond laser interface and microkeratome cutting head.
2012
PURPOSE: To evaluate the irregularity of the posterior corneal surface and intrastromal dissection during the preparation of donor tissue for Descemet stripping automated endothelial keratoplasty (DSAEK) using a curved interface femtosecond laser and microkeratome. METHODS: Sixteen human donor corneas unsuitable for transplantation were divided into two groups: a femtosecond (FS) laser group (n=7) using the VisuMax femtosecond laser (Carl Zeiss Meditec) and a microkeratome group (n=9) using the Amadeus II microkeratome (Ziemer Ophthalmic Group). The corneas were fixed on artificial anterior chambers. Horizontal cross-sections were obtained using spectral-domain optical coherence tomography…
Bilateral Ultrathin Descemet’s Stripping Automated Endothelial Keratoplasty vs. Bilateral Penetrating Keratoplasty in Fuchs’ Dystrophy: Corneal Highe…
2021
Background and Objectives: The objective of this paper is to compare the visual outcomes and quality of life (QoL) after bilateral ultrathin Descemet’s stripping automated endothelial keratoplasty (UT-DSAEK) with bilateral penetrating keratoplasty (PK) for Fuchs’ endothelial dystrophy (FED). Materials and Methods: Retrospective comparative cohort study, including 11 patients with FED who underwent bilateral PK and 13 patients with FED who underwent bilateral UT-DSAEK. All patients were already pseudophakic or had undergone a combined cataract procedure. The main outcomes were corrected distance visual acuity (CDVA) corneal higher-order aberrations (HOAs), contrast sensitivity (CS) and quali…
Optical quality of hyperopic and myopic phakic intraocular lenses
2013
Aims: To assess and compare the optical quality of the myopic and hyperopic implantable collamer lens (ICL) from its wavefront aberrations for different powers and pupil diameters. Settings and Design: Prospective study. Material and Methods: The wavefront aberrations of two myopic (−3 and −6 diopters (D)) and two hyperopic V4b ICLs (+3 and +6D) were measured in vitro . To assess and compare the optical quality of different powers of ICLs, we analyzed the root mean square (RMS) of total higher order aberrations (HOAs), trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration at 3- and 4.5-mm pupil. In addition, the point spread functions (PSFs) of each ICL evaluated were ca…