Search results for "lcsh:QC350-467"
showing 10 items of 35 documents
Phase-Sensitive Detection for Optical Sensing With Porous Silicon
2012
We report on a photonic sensor with an ultralow limit of detection (LoD) based on a phase interrogation readout scheme together with an anisotropic porous silicon (PSi) membrane. First, the fabrication of porous free-standing membranes from medium doped (100) surface oriented silicon, with pore diameters suitable for the infiltration of biomolecules, around 50 nm, is reported. Then, the phase interrogation scheme for characterizing the PSi membranes is presented whose results show that while volumetric sensitivity increases with the membrane thickness, the resolution in the birefringence measurements decrease dramatically due to depolarization effects. The best LoD was found to be equal to …
Electro-optical characterization of new classes of Silicon Carbide UV photodetectors
2014
In this paper, we present the fabrication process steps and the characterization of 4H-SiC vertical Schottky UV detectors, where interdigitated strips, acting as top metal contacts, have been realized in $\hbox{Ni}_{2}\hbox{Si}$ . These devices exploit the pinch-off surface effect. $I$ – $V$ and $C$ – $V$ characteristics, as functions of temperature, were measured in dark conditions. In addition, we have carried out responsivity measurements, for wavelengths ranging from 200 to 400 nm, at varying package temperature and applied reverse bias. A comparison among devices having different strip pitch sizes has been performed, thus finding out that the 10- $\mu\hbox{m}$ pitch class demonstrates …
All-Fiber Laser With Intracavity Acousto-Optic Dynamic Mode Converter for Efficient Generation of Radially Polarized Cylindrical Vector Beams
2017
We report an all-fiber laser that emits a radially polarized cylindrical vector beam (CVB) at 1 μm based on an intracavity acousto-optic mode converter. We efficiently generate the CVB, taking advantage of the acousto-optic coupling from the HE11 mode to the TM01 mode in a two-mode fiber. The laser can be switched from emitting a Gaussian-like beam to a radially polarized CVB. Radially polarized CVBs with modal and polarization purities >98% and a maximum power of 65 mW were generated.
Spatial localization of hotspots in Fano-resonant plasmonic oligomers for surface-enhanced coherent anti-Stokes Raman scattering
2020
AbstractRealization of Fano resonance in plasmonic oligomers is often exploited to design efficient plasmonic substrates for surface-enhanced coherent anti-Stokes Raman scattering. Disk-type Fano-resonant plasmonic oligomers are widely used to enhance the Raman signal of the probe material. Generally, hot spots are generated in those oligomers at different spatial locations at different wavelengths and only a few spatially overlapping hot spots at multiple wavelengths can be achieved with oblique incidence of excitation light. In this work, we proposed hexagonal gold nanoparticle based Fano-resonant plasmonic oligomers that can yield higher number of spatially overlapped hot spots compared …
Nonlinear Disorder Mapping Through Three-Wave Mixing
2010
We implement a simple and powerful approach to characterize the domain distribution in the bulk of quadratic ferroelectric crystals via far-field second-harmonic spectroscopy. The approach is demonstrated in a lithium tantalate sample with periodic electric field poling and random mark-to-space ratio.
Employing Microwave Graphene Field Effect Transistors for Infrared Radiation Detection
2018
In this work, we investigate the possibility of employing graphene field effect transistors, specifically designed for microwave applications, as infrared detectors for telecom applications. Our devices have been fabricated on a sapphire substrate employing CVD-grown transferred graphene. The roles of both the gate dielectric and the DC bias conditions have been evaluated in order to maximize the infrared generated signal through an experimental investigation of the signal-to-noise ratio dependence on the transistor operating point.
Fabrication-friendly polarization-sensitive plasmonic grating for optimal surface-enhanced Raman spectroscopy
2020
Plasmonic nanostructures are widely utilized in surface-enhanced Raman spectroscopy (SERS) from ultraviolet to near-infrared applications. Periodic nanoplasmonic systems such as plasmonic gratings are of great interest as SERS-active substrates due to their strong polarization dependence and ease of fabrication. In this work, we modelled a silver grating that manifests a subradiant plasmonic resonance as a dip in its reflectivity with significant near-field enhancement only for transverse-magnetic (TM) polarization of light. We investigated the role of its fill factor, commonly defined as a ratio between the width of the grating groove and the grating period, on the SERS enhancement. We des…
Retinal Straylight Before and After Penetrating Keratoplasty in an Eye with a Post-Herpetic Corneal Scar
2008
Objetivo: Estudio in vivo de la luz dispersa que alcanza la retina en un paciente antes y despues de someterse a una queratoplastia penetrante (o sus siglas en ingles, PKP). Metodos: En un paciente varon de 65 anos con una ulcera corneal herpetica se midio la proporcion de luz dispersa que alcanza la retina tanto antes como despues de una PKP, utilizando para ello un metodo psicometrico denominado "de comparacion por compensacion" («Compensation comparison method», C-Quant straylightmeter, Oculus GmbH, Alemania). Resultados: La cantidad de luz dispersa que alcanza la retina medida antes de la cirugia fue elevada en comparacion con los valores obtenidos en estudios previos en sujetos normale…
Variations of OCT measurements corrected for the magnification effect according to axial length and refractive error in children
2018
Purpose: The aim of this paper was to examine the distribution of macular, retinal nerve fiber layer (RNFL) thickness and optic disc parameters of myopic and hyperopic eyes in comparison with emmetropic control eyes and to investigate their variation according to axial length (AL) and spherical equivalent (SE) in healthy children. Methods: This study included 293 pairs of eyes of 293 children (145 boys and 148 girls), ranging in age from 6 to 17 years. Subjects were divided according to SE in control (emmetropia, 99 children), myopia (100 children) and hyperopia (94 children) groups and according to axial AL in 68 short ([Formula: see text]22.00[Formula: see text]mm, 68), medium (from [For…
Biometric characterization of the anterior segment in a Sahrawi pediatric population
2013
Purpose: To examine the biometric characteristics of the anterior segment in a group of Sahrawi children. Methods: A total of 66 children (33 male and 33 female, aged between 8 and 13 years) participated in this prospective, observational study. The non-invasive Pentacam Scheimpflug imaging device was used to measure corneal thickness (CT) (at the thinnest corneal point), mean anterior (Km Ant) and posterior (Km Post) corneal radii, corneal volume (CVol), anterior chamber depth (ACD) and anterior chamber volume (ACVol). The contribution of age and gender to the various parameters was investigated. Results: CT values of the present group of Sahrawi children were 521.70 ± 3.92 m. Boys had thi…