Search results for "leakage"

showing 10 items of 146 documents

Impact of Gamma Radiation on Dynamic RDSON Characteristics in AlGaN/GaN Power HEMTs

2019

GaN high-electron-mobility transistors (HEMTs) are promising next-generation devices in the power electronics field which can coexist with silicon semiconductors, mainly in some radiation-intensive environments, such as power space converters, where high frequencies and voltages are also needed. Its wide band gap (WBG), large breakdown electric field, and thermal stability improve actual silicon performances. However, at the moment, GaN HEMT technology suffers from some reliability issues, one of the more relevant of which is the dynamic on-state resistance (R) regarding power switching converter applications. In this study, we focused on the drain-to-source on-resistance (R) characteristic…

Materials scienceassurance testingRadiation effects02 engineering and technologyHigh-electron-mobility transistorradiation hardness01 natural scienceslcsh:Technologylaw.inventiontotal ionizing dose (TID)lawPower electronics0103 physical sciencesGeneral Materials Sciencelcsh:MicroscopyHigh-electron-mobility transistor (HEMT)Radiation hardeningLeakage (electronics)lcsh:QC120-168.85010302 applied physicsRadiation hardnessAssurance testinghigh-electron-mobility transistor (HEMT)lcsh:QH201-278.5business.industrylcsh:TTransistorWide-bandgap semiconductor021001 nanoscience & nanotechnologyThreshold voltageSemiconductorlcsh:TA1-2040Gallium nitride (GaN)adiation effectsradiation effectsOptoelectronicslcsh:Descriptive and experimental mechanicslcsh:Electrical engineering. Electronics. Nuclear engineeringTotal ionizing dosegallium nitride (GaN)0210 nano-technologybusinesslcsh:Engineering (General). Civil engineering (General)lcsh:TK1-9971Materials
researchProduct

An in vitro evaluation of two dentine adhesive systems to seal the pulp chamber using a glucose penetration model

2010

Objectives: To evaluate the sealing capability of Cavit TM G with or without Clearfil TM S3 Bond and Prime & Bond NT placed in the pulp chamber. Study Design: Forty single rooted premolars, extracted for orthodontic and periodontal reasons, with intact coronal surface and mature apices, were standardized to a length of 15 mm. The teeth were instrumented, filled with a gutta-percha master cone and divided into three groups to obturate the pulp chambers: Cavit TM G; Clearfil TM S3 Bond plus Cavit TM G and Prime & Bond® NT plus Cavit TM G. A glucose leakage model was used for evaluating the coronal microleakage. The Mann-Whitney test was used to evaluate the differences in the means of the glu…

Dental Pulp CavityDental LeakageMaterials scienceTime Factorsbusiness.industryDentistryPenetration (firestop)In Vitro Techniques:CIENCIAS MÉDICAS [UNESCO]Models BiologicalGlucoseOtorhinolaryngologyDentin-Bonding AgentsDentine adhesiveUNESCO::CIENCIAS MÉDICASPulp (tooth)HumansSurgeryDental Pulp CavitybusinessGeneral DentistryDentin Bonding Agents
researchProduct

Fault Diagnosis for Nonlinear Hydraulic-Mechanical Drilling Pipe Handling System

2011

Leakage and increased friction are common faults in hydraulic cylinders that can have serious consequences if they are not detected at early stage. In this paper, the design of a fault detector for a nonlinear hydraulic mechanical system is presented. By considering the system in steady state, two residual signals are generated and analysed with a composite hypothesis test which accommodates for unknown parameters. The resulting detector is able to detect abrupt changes in leakage or friction given the noisy pressure and position measurements. Test rig measurements validate the properties of residuals and high fidelity simulation and experimental results demonstrate the performance and feas…

Mechanical systemEngineeringNonlinear systemHydraulic cylinderbusiness.industryDetectorStructural engineeringHydraulic machinerybusinessResidualLeakage (electronics)Statistical hypothesis testing
researchProduct

Impact of Terrestrial Neutrons on the Reliability of SiC VD-MOSFET Technologies

2021

Accelerated terrestrial neutron irradiations were performed on different commercial SiC power MOSFETs with planar, trench and double-trench architectures. The results were used to calculate the failure cross-sections and the failure in time (FIT) rates at sea level. Enhanced gate and drain leakage were observed in some devices which did not exhibit a destructive failure during the exposure. In particular, a different mechanism was observed for planar and trench gate MOSFETs, the first showing a partial gate rupture with a leakage path mostly between drain and gate, similar to what was previously observed with heavy-ions, while the second exhibiting a complete gate rupture. The observed fail…

Nuclear and High Energy PhysicsMaterials sciencepower MOSFETs01 natural sciences7. Clean energyelektroniikkakomponentitStress (mechanics)chemistry.chemical_compoundReliability (semiconductor)silicon carbidepuolijohteet0103 physical sciencesMOSFETSilicon carbideElectrical and Electronic EngineeringPower MOSFETSilicon Carbide; Power MOSFETs; neutrons; Single Event Effects; Single Event Burnout; gate damagesingle event burnoutLeakage (electronics)010308 nuclear & particles physicsbusiness.industrygate damageneutronsneutronitsingle event effectssäteilyfysiikkaNuclear Energy and EngineeringchemistryLogic gateTrenchtransistoritOptoelectronicsOtherbusinessIEEE Transactions on Nuclear Science
researchProduct

Quantitative thermoelastic stress analysis by means of low-cost setups

2020

Abstract A low-cost Thermoelastic Stress Analysis (TSA) experimental setup is proposed which uses an ordinary micro-bolometer and in-house developed signal processing scripts. The setup is evaluated by analysing the thermoelastic signal from a tensile and a SENT specimen made of stainless steel AISI 304L, and the bolometer performances are compared with those of a state of the art photon detector. Signal processing is based on off-line cross-correlation, using a self-reference signal which is retrieved from the acquired thermal data. Procedures are in particular developed to recognise, quantify and correct errors due to spectral leakage and loss of streamed frames. The thermoelastic signal …

Signal processingMaterials scienceMicro-bolometersAcoustics/dk/atira/pure/subjectarea/asjc/2500/2504/dk/atira/pure/subjectarea/asjc/2200/2208Crack-growth monitoringThermoelastic stress analysis02 engineering and technologyFatigue testing01 natural sciencesSignallaw.invention010309 opticsSettore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchineThermoelastic dampingData acquisitionlaw0103 physical sciencesCalibrationElectrical and Electronic EngineeringSpectral leakageStress intensity factorSignal processing/dk/atira/pure/subjectarea/asjc/3100/3107Mechanical EngineeringBolometer021001 nanoscience & nanotechnologyAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsIR-thermography/dk/atira/pure/subjectarea/asjc/2200/22100210 nano-technology
researchProduct

A New Model of Skull Base Reconstruction following Expanded Endonasal or Transoral Approaches – Long-Term Results in Primates

2007

<i>Objective:</i> The direct endonasal or transoral transclival approaches to the skull base permit effective minimally invasive surgery along the clivus region. Developing consistently effective techniques to prevent cerebrospinal fluid (CSF) leaks and their consequences (infections and healing processes with long and complicated recoveries) remains a major challenge. In this study, we tested over a long period a method of bone reconstruction newly developed by us, which makes use of a specially designed elastic silicone plug that can be employed for bone replacement after minimally invasive skull base surgery without risk of postoperative CSF leaks. After acute testing of plug…

Malemedicine.medical_specialtySiliconesPostoperative ComplicationsClivusmedicineAnimalsMinimally Invasive Surgical ProceduresBase (exponentiation)Cerebrospinal FluidSkull BaseCerebrospinal Fluid Leakagebusiness.industryForeign-Body ReactionSilicone plugEndoscopyProstheses and ImplantsLong term resultsPlastic Surgery ProceduresAnti-Bacterial AgentsSurgerySkullmedicine.anatomical_structureModels AnimalSkull base surgeryInvasive surgeryPapio hamadryasSurgerybusinessEuropean Surgical Research
researchProduct

Microbiological assessment of the implant-abutment interface in different connections: cross-sectional study after 5 years of functional loading.

2014

Objective To evaluate the bacterial microflora present inside the implant connection and in the peri-implant sulcus fluid of healthy implants, and to analyze the relationships between these harboring sites for four different implant systems after at least 5 years of functional loading. Materials and methods A cross-sectional study was performed involving 40 patients treated with metal-ceramic cemented bridges supported by at least two healthy implants functionally loaded for 5 years. Four different implant-abutment connections were studied: external hexagon (control group), double internal hexagon (test group 1), internal hexagon with external collar (test group 2), and conical connection (…

MaleDentistryEikenella corrodensDental AbutmentsClinical study; Implant connection; Implant-abutment microgap; Microbial leakageClinical studyImplant-abutment microgapHumansAgedDental Implantsbiologybusiness.industryAggregatibacter actinomycetemcomitansPrevotella intermediaCampylobacter rectusTreponema denticolaDental Implant-Abutment DesignGingival Crevicular Fluidbiology.organism_classificationRed complexCross-Sectional StudiesTreatment OutcomeImplant connectionFemaleImplantMicrobial leakageDental Prosthesis Implant-SupportedOral SurgeryFusobacterium nucleatumbusinessClinical oral implants research
researchProduct

A comparative study of the sealing ability of two root canal obturation techniques

1995

A comparison was made of the ability of two root canal obturating techniques to prevent dye microleakage: gutta-percha lateral condensation and mechanically plasticized gutta-percha (JS Quick-fill). Twenty central incisors were prepared and obturated by each technique. After rendering the teeth transparent, linear dye penetration was found to be 0.48 and 0.52 mm, respectively. The difference between the two techniques was not significant. As for the distribution of the sealing cement (AH26) in the teeth obturated with JS Quickfill, the cement was located in the most peripheral zone of the obturation alongside the dentinal walls, whereas the gutta-percha was found in the central part of the …

Dental LeakageDye penetrationCementJS-quickfillRoot Canal ObturationMaterials sciencebusiness.industryRoot canalDentistryLateral condensationIncisorstomatognathic diseasesPeripheral zonemedicine.anatomical_structurestomatognathic systemEvaluation Studies as TopicRoot Canal ObturationmedicineHumansMaxillary central incisorGutta-PerchabusinessGeneral DentistryJournal of Endodontics
researchProduct

SETUP OF VIRTUAL EXPERIMENTS AND CRITICAL ANALYSIS OF CONVENTIONAL THERMOECONOMIC DIAGNOSIS OF MULTIPLE FAULTS IN AIR-CONDENSED ROOFTOP SYSTEMS

2012

The diagnosis of soft faults in vapor compression cooling systems is a crucial activity, since malfunctions may provoke heavy degradation in plant performance and increase the power consumption for space cooling. Among the various Faults Detection and Diagnosis techniques developed over the last two decades, thermoeconomic diagnosis has been playing only a marginal role due to the difficulties encountered when applying the conventional thermoeconomic approaches to vapor compression refrigeration plants. In this paper a critical analysis on capabilities and limits of thermoeconomic diagnosis of refrigeration systems is proposed. The reference plant assumed for this study is a 116 kWc air-con…

ExergyCost allocationEngineeringbusiness.industryRefrigerationMechanical engineeringEnergy consumptionReliability engineeringRefrigerantAir conditioningThermoeconomic diagnosis refrigeration multiple faults virtual experimentSettore ING-IND/10 - Fisica Tecnica IndustrialeVapor-compression refrigerationbusinessLeakage (electronics)
researchProduct

Does Optimal Volume Fraction in Percutaneous Vertebroplasty Prevent Cement Leakage?

2018

CementVertebroplastybusiness.industrymedicine.medical_treatmentPercutaneous Vertebroplasty vertebral fracture cementBone CementsPercutaneous vertebroplasty03 medical and health sciences0302 clinical medicineVolume fractionFractures CompressionmedicineSpinal FracturesSurgery030216 legal & forensic medicine030212 general & internal medicineNeurology (clinical)businessBiomedical engineeringCement leakageWorld neurosurgery
researchProduct