Search results for "lens"
showing 10 items of 948 documents
Fighting carbon loss of degraded peatlands by jump-starting ecosystem functioning with ecological restoration
2015
Degradation of ecosystems is a great concern on the maintenance of biodiversity and ecosystem services. Ecological restoration fights degradation aiming at the recovery of ecosystem functions such as carbon (C) sequestration and ecosystem structures like plant communities responsible for the C sequestration function. We selected 38 pristine, drained and restored boreal peatland sites in Finland and asked i) what is the long-term effect of drainage on the peatland surface layer C storage, ii) can restoration recover ecosystem functioning (surface layer growth) and structure (plant community composition) and iii) is the recovery of the original structure needed for the recovery of ecosystem f…
Perfiles de potencia de las lentes de contacto medidas con NIMO TR1504
2017
This study was supported by the Ministerio de Economía y Competitividad and FEDER (Grant DPI2015-71256-R) and by the Generalitat Valenciana (Grant PROMETEOII-2014-072), Spain.
Repeatability of in vitro power profile measurements for multifocal contact lenses
2015
Abstract Purpose To evaluate the repeatability of an optical device (NIMO TR1504, Lambda-X, Belgium) for measuring multifocal contact lens power profiles. Methods The NIMO TR1504 was used to measure power profiles 30 times for each of 10 different contact lenses from 4 major companies. All contact lenses were labelled as −3 D for distance vision; half were for high addition and half for low addition. The optical zone in all measurements was set to 3-mm radius. For each lens, the median power profile and the residuals of the 30 measurements were calculated. The 95% confidence bands and two indices that summarize measurement errors were calculated: the repeatability limit and an index of repe…
Antibacterial and antifungal effects of soft contact lens disinfection solutions.
1998
To study the antibacterial and antifungal effects of soft contact lens disinfection solutions.Eight contact lens disinfection solutions containing hydrogen peroxide or biguanides or polyquad compounds were evaluated with respect to their ability to disinfect a saline solution experimentally contaminated with different bacteria and with a fungus. We used cultures in blood Agar, MuellerHinton agar and Saboureaud's agar to identify the bacterial and fungal growth following 14 h of exposure to the disinfection solutions.Hydrogen peroxide, DYMED and polyhexamide solutions prevented the growth of the four bacteria studied. The solution containing biguanide prevented the growth of Escherichia coli…
pH of multipurpose contact lens solutions over time
1998
The pH of nine different brands of multipurpose contact lens solutions available in Spain was determined over a period of 32 days after opening the bottles. Five bottles of nine solutions were used, each of which was buffered and obtained from different manufacturers. The pH measurements were taken using a micropH 2002 Crison pH-meter (accuracy +/- 0.001 pH units). Each solution was measured three times daily over the test period using 10-ml samples taken from the same container. Fluctuations in pH over time were observed but these were within the range of ocular comfort. The average pH of all the solutions tested proved to be between 6.99 and 7.56.
Comparative study of pH for different saline and multi-purpose contact lens solutions.
1997
In this study, we determined the pH of different saline and multipurpose contact lens solutions available on the Spanish market. We examined 10 samples of 14 solutions, seven of which are saline solutions and seven multipurpose ones, from different manufacturers. Both types of solution were found to have significant variations in pH, with values ranging from 6.70 to 7.57 for the saline solutions and 6.84 to 7.63 for the multipurpose solutions. We concluded that the solutions should not affect the ocular physiological performance because their pH values are within the buffering capacity of the eye.
The impact of daily disposable soft contact lens wear on tear film surface quality over a three month period
2017
“In situ” corneal and contact lens thickness changes with high resolution OCT
2012
Purpose: To show the utility of high resolution spectral domain optical coherence tomography (HR SOCT) for the in situ evaluation of epithelial, stromal and contact lens (CL) thickness changes under closed-eye conditions without lens removal. Settings: Clinical and Experimental Optometry Research Lab, University of Minho, Portugal. Methods: Eight young healthy patients wore a thick soft CL during 90 minutes under closed-eye conditions and measures of epithelial and stromal corneal thickness were obtained at regular intervals using a HR SOCT (Copernicus HR, Optopol Tech. SA, Poland). Results: Minimal changes in epithelial thickness were detected with a transient statistically significant inc…
Corneal aberrations pre and post-application of new contact lens in the astigmatism after penetrating keratoplasty.
2007
The Impact of the Mass Spectrum of Lenses in Quasar Microlensing Studies. Constraints on a Mixed Population of Primordial Black Holes and Stars
2020
We show that quasar microlensing magnification statistics induced by a population of point microlenses distributed according to a mass-spectrum can be very well approximated by that of a single-mass, "monochromatic", population. When the spatial resolution (physically defined by the source size) is small as compared with the Einstein radius, the mass of the monochromatic population matches the geometric mean of the mass-spectrum. Otherwise, the best-fit mass can be larger. Taking into account the degeneracy with the geometric mean, the interpretation of quasar microlensing observations under the hypothesis of a mixed population of primordial black holes and stars, makes the existence of a s…