Search results for "libration"

showing 10 items of 901 documents

Calibration of an airborne HO<sub><i>x</i></sub> instrument using the All Pressure Altitude-b…

2020

Abstract. Laser-induced fluorescence (LIF) is a widely used technique for both laboratory-based and ambient atmospheric chemistry measurements. However, LIF instruments require calibrations in order to translate instrument response into concentrations of chemical species. Calibration of LIF instruments measuring OH and HO2 ( HOx ) typically involves the photolysis of water vapor by 184.9 nm light, thereby producing quantitative amounts of OH and HO2 . For ground-based HOx instruments, this method of calibration is done at one pressure (typically ambient pressure) at the instrument inlet. However, airborne HOx instruments can experience varying cell pressures, internal residence times, tempe…

010302 applied physicsAtmospheric ScienceMaterials science010504 meteorology & atmospheric sciencesNozzleDetectorAnalytical chemistryHumidity01 natural sciencesAtmospheric chemistry0103 physical sciencesCalibrationPressure altitudeWater vapor0105 earth and related environmental sciencesAmbient pressureAtmospheric Measurement Techniques
researchProduct

The filter and calibration wheel for the ATHENA wide field imager

2016

The planned filter and calibration wheel for the Wide Field Imager (WFI) instrument on Athena is presented. With four selectable positions it provides the necessary functions, in particular an UV/VIS blocking filter for the WFI detectors and a calibration source. Challenges for the filter wheel design are the large volume and mass of the subsystem, the implementation of a robust mechanism and the protection of the ultra-thin filter with an area of 160 mm square. This paper describes performed trade-offs based on simulation results and describes the baseline design in detail. Reliable solutions are envisaged for the conceptual design of the filter and calibration wheel. Four different varian…

010302 applied physicsComputer scienceDetectorFilter wheel mechanism FEM structural and acoustic analysis ATHENA WFIVolume (computing)Blocking (statistics)01 natural sciencesSquare (algebra)Settore FIS/05 - Astronomia E AstrofisicaPosition (vector)Filter (video)0103 physical sciencesElectronic engineeringCalibration010303 astronomy & astrophysicsSimulation
researchProduct

Conic optical fiber probe for generation and characterization of microbubbles in liquids

2021

Abstract A novel optical fiber probe has been developed to provide mechanical stability to microbubbles generated in fluids, the tip of the fiber is etched with hydrofluoric acid to pierce a truncated horn that fastens the microbubbles to the fiber tip and prevents misalignment or detachment caused by convection currents, vibrations or shocks in the liquid. Microbubbles are photo-thermally generated on the etched fiber and used as Fabry-Perot cavity sensor. Two methods were used to interrogate the probe: the first one, in the wavelength domain, is suitable for calibration in static or quasi static situations; the second one, in the time domain, can be used in dynamic environments. Experimen…

010302 applied physicsConvectionMaterials sciencebusiness.industryMetals and Alloys02 engineering and technology021001 nanoscience & nanotechnologyCondensed Matter Physics01 natural sciencesSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsWavelengthOptics0103 physical sciencesMicrobubblesCalibrationFiberTime domainElectrical and Electronic Engineering0210 nano-technologybusinessInstrumentationQuasistatic processBar (unit)Sensors and Actuators A: Physical
researchProduct

Analog isolated electronic dynamometer based on a magnetoresistive current sensor.

2017

In this work, an electronic system is presented to measure the force applied by a solenoid. The originality of the work is focused on the use of a magnetoresistive current sensor to provide the isolation barrier needed in the actual industrial plant where the solenoids are working. The design of the electronic system is presented as well as experimental measurements as a result of a calibration process showing a negligible hysteresis with that specific sensor. The magnetoresistive current sensor is used to develop transmission functions rather than playing its usual sensing roles.

010302 applied physicsDynamometerMagnetoresistancebusiness.industryComputer science010401 analytical chemistryElectrical engineeringProcess (computing)Solenoid01 natural sciences0104 chemical sciencesHysteresisNuclear magnetic resonanceTransmission (telecommunications)0103 physical sciencesCalibrationCurrent sensorbusinessInstrumentationThe Review of scientific instruments
researchProduct

Mass calibration of the energy axis in ToF- E elastic recoil detection analysis

2016

We report on procedures that we have developed to mass-calibrate the energy axis of ToF-E histograms in elastic recoil detection analysis. The obtained calibration parameters allow one to transform the ToF-E histogram into a calibrated ToF-M histogram.

010302 applied physicsPhysicsNuclear and High Energy Physicsta114Physics::Instrumentation and DetectorsPhysics::Medical PhysicsAstrophysics::Instrumentation and Methods for AstrophysicsERD02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesNuclear physicsElastic recoil detectionComputer Science::Computer Vision and Pattern RecognitionHistogramelastic recoil detection analysis0103 physical sciencesCalibrationmass calibrationToF-ENuclear Experiment0210 nano-technologyInstrumentationEnergy (signal processing)Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Silicon dosimeters based on Floating Gate Sensor: design, implementation and characterization

2020

A rad-hard monolithic dosimeter has been implemented and characterized in a standard 180 nm CMOS technology. The radiation sensor (C-sensor) is based on a Floating Gate (FG) MOS discharge principle. The output current is processed by a current-to-voltage (I/V) interface and then converted by a 5-bit flash ADC. The dosimeter is re-usable (FG can be recharged) and can detect a dose up to 1krad (Si) with a resolution of 30rad (Si) typical over temperature 0 to 85°C range. The ADC allows easy further signal processing for calibration and averaging, etc. The power consumption of C-sensor plus I/V interface is < 2mW from a 5 V power supply. The overall layout area is less than 0.25mm2. The Rad…

010302 applied physicsSignal processingMaterials scienceDosimeterSettore ING-IND/20 - Misure E Strumentazione Nucleari010308 nuclear & particles physicsbusiness.industryAnalog-to-digital converterHardware_PERFORMANCEANDRELIABILITYFlash ADC01 natural sciencesPower (physics)law.inventionCMOSlawAnalog-to-Digital converter current-to-voltage interfaces Dosimeter edgeless transistors (ELT) Floating Gate MOS radiation hardening by design (RHBD) total ionizing dose (TID)Absorbed dose0103 physical sciencesHardware_INTEGRATEDCIRCUITSCalibrationOptoelectronicsbusiness2020 IEEE 20th Mediterranean Electrotechnical Conference ( MELECON)
researchProduct

A New LA ‐ ICP ‐ MS Method for Ti in Quartz: Implications and Application to High Pressure Rutile‐Quartz Veins from the Czech Erzgebirge

2016

Experimental determination of the pressure and temperature controls on Ti solubility in quartz provides a calibration of the Ti-in-quartz (TitaniQ) geothermometer applicable to geological conditions up to ~ 20 kbar. We present a new method for determining 48Ti mass fractions in quartz by LA-ICP-MS at the 1 μg g−1 level, relevant to quartz in HP-LT terranes. We suggest that natural quartz such as the low-CL rims of the Bishop Tuff quartz (determined by EPMA; 41 ± 2 μg g−1 Ti, 2s) is more suitable than NIST reference glasses as a reference material for low Ti mass fractions because matrix effects are limited, Ca isobaric interferences are avoided, and polyatomic interferences at mass 48 are i…

010401 analytical chemistryPolyatomic ionAnalytical chemistrychemistry.chemical_elementMineralogyGeologyElectron microprobe010502 geochemistry & geophysics01 natural sciences0104 chemical scienceschemistryGeochemistry and PetrologyRutileCalibrationIsobaric processMass fractionQuartz0105 earth and related environmental sciencesTitaniumGeostandards and Geoanalytical Research
researchProduct

Dissipative analogies of step-pool features: From rills to mountain streams

2019

Abstract In this paper the dissipative similarity of step-pool units at different spatial scales ranging from rills to streams is analyzed. This investigation benefits from the latest theoretical advances in open channel flow resistance, high-resolution topography from close-range photogrammetry applied to rill erosion and the availability of published data from literature on step-pool streams. At first, the integration of a power velocity distribution allowed to obtain a theoretically-based expression of Darcy-Weisbach friction factor, in which Γ function and δ exponent of the velocity profile are included. Then this theoretically-deduced flow resistance relationship is calibrated and test…

010504 meteorology & atmospheric sciencesFlow (psychology)GeometrySTREAMSPlot measurement01 natural sciencesFlow velocityCalibrationSettore AGR/08 - Idraulica Agraria E Sistemazioni Idraulico-Forestali0105 earth and related environmental sciencesEarth-Surface Processesgeographygeography.geographical_feature_category04 agricultural and veterinary sciencesFunction (mathematics)Open-channel flowRillFlow velocityFlow resistance040103 agronomy & agricultureDissipative systemRill flowSoil erosion0401 agriculture forestry and fisheriesStep-poolGeology
researchProduct

Radiometric calibration of SeaWIFS in the near infrared

2005

The radiometric calibration of the Sea-Viewing Wide-Field-of-View Sensor (SeaWiFS) in the near infrared (band 8, centered on 865 nm) is evaluated by use of ground-based radiometer measurements of solar extinction and sky radiance in the Sun's principal plane at two sites, one located 13 km off Venice, Italy, and the other on the west coast of Lanai Island, Hawaii. The aerosol optical thickness determined from solar extinction is used in an iterative scheme to retrieve the pseudo aerosol phase function, i.e., the product of single-scattering albedo and phase function, in which sky radiance is corrected for multiple scattering effects. No assumption about the aerosol model is required. The ae…

010504 meteorology & atmospheric sciencesMaterials Science (miscellaneous)Solar zenith angle01 natural sciencesIndustrial and Manufacturing Engineering010309 optics[SDU.STU.CL] Sciences of the Universe [physics]/Earth Sciences/ClimatologyOptics0103 physical sciences14. Life underwaterBusiness and International ManagementRadiometric calibration0105 earth and related environmental sciencesRemote sensingRadiometerbusiness.industryAtmospheric correctionAerosolSeaWiFS13. Climate action[SDU.STU.CL]Sciences of the Universe [physics]/Earth Sciences/ClimatologyInfrared windowRadianceEnvironmental science[ SDU.STU.CL ] Sciences of the Universe [physics]/Earth Sciences/Climatologybusiness
researchProduct

Validation of SMAP surface soil moisture products with core validation sites

2017

Abstract The NASA Soil Moisture Active Passive (SMAP) mission has utilized a set of core validation sites as the primary methodology in assessing the soil moisture retrieval algorithm performance. Those sites provide well-calibrated in situ soil moisture measurements within SMAP product grid pixels for diverse conditions and locations. The estimation of the average soil moisture within the SMAP product grid pixels based on in situ measurements is more reliable when location specific calibration of the sensors has been performed and there is adequate replication over the spatial domain, with an up-scaling function based on analysis using independent estimates of the soil moisture distributio…

010504 meteorology & atmospheric sciencesMean squared error0211 other engineering and technologiesSoil Science02 engineering and technology01 natural scienceslaw.inventionlawValidationCalibrationComputers in Earth SciencesRadarSpatial domainWater content021101 geological & geomatics engineering0105 earth and related environmental sciencesRemote sensingRadiometerPixelGeologySMAP22/4 OA procedureITC-ISI-JOURNAL-ARTICLEEnvironmental scienceSatelliteSoil moisture
researchProduct