Search results for "libration"
showing 10 items of 901 documents
Study and simulation of the read-out electronics design for a high-resolution plastic scintillating fiber based hodoscope
2015
Abstract This work presents the study and simulation of a high-resolution charged particle detection device for beam positioning, monitoring and calibration, together with its read-out proposal. To provide the precise positional information of the beam, the detection system has been based on Plastic Scintillating Fibers (PSF), while the read-out on a Silicon-PhotoDiode (Si-PD) array. To carry out the study, a PSF prototype with one detection plane has been experimentally tested with a β particle source. Besides, Monte Carlo simulations of the complete system have also been conducted. Both simulations and experimental tests give consistency to the results obtained. The work presented in this…
Calibration of a neutron time-of-flight multidetector system for an intensity interferometry experiment
2004
We present the details of an experiment on light particle interferometry. In particular, we focus on a time-of-flight technique which uses a cyclotron RF signal as a start and a liquid scintillator time signal as a stop, to measure neutron energy in the range of En approximate to 1.8-150 MeV. This dynamic range (up to 300 ns) is much larger than the beam bunch separation (54 ns) of the AGOR cyclotron (KVI). However, the problem of a short burst period is overcome by using the time information obtained from a fast projectile fragment phoswich detector. The complete analysis procedure to extract the final neutron kinetic energy spectra, is discussed. (C) 2003 Elsevier B.V. All rights reserved.
Efficiency calibration of a Ge(Li) detector by absolute counting of fallout nuclides by means of the 4πβ-γ coincidence method
1975
Abstract The 4 π β - γ coincidence method proves to be very suitable for absolute counting of fallout nuclides. Using such nuclides, absolute calibration of a Ge(Li) detector was carried out for different geometry positions.
Energy calibration and monitoring of the KATRIN experiment
2011
A new high precision voltage divider has been built for monitoring the analysing potential of the KATRIN main spectrometer. In addition a condensed 83mKr calibration source has been set up at the modified 1 eV resolving Mainz spectrometer, our measurements show that energy calibration and monitoring for KATRIN is feasible at the few ppm level.
Nanobeacon and laser beacon: KM3NeT time calibration devices
2015
In-Situ Calibration of UFFO/Lomonosov for Observation of GRBs
2017
The UFFO/Lomonosov has been successfully launched into Sun synchronous orbit and is operational through tests and calibrations since its launch on Apr. 28, 2016. As a pathfinder of UFFO, it will be the first space instrument to use a fast slewing mirror which reduce the trigger latency of optical telescope, less than a second, to explore early time domain of GRB evolution. In this article, we will report in detail the first mission, UFFO/Lomonosov, for the rapid response to observe early photons from GRBs in orbit.
2017
In the EXILL campaign a highly efficient array of high purity germanium (HPGe) detectors was operated at the cold neutron beam facility PF1B of the Institut Laue-Langevin (ILL) to carry out nuclear structure studies, via measurements of γ-rays following neutron-induced capture and fission reactions. The setup consisted of a collimation system producing a pencil beam with a thermal capture equivalent flux of about 108 n s−1cm−2 at the target position and negligible neutron halo. The target was surrounded by an array of eight to ten anti-Compton shielded EXOGAM Clover detectors, four to six anti-Compton shielded large coaxial GASP detectors and two standard Clover detectors. For a part of the…
Software Timing Calibration of the ARGO-YBJ Detector
2009
The ARGO-YBJ experiment is mainly devoted to search for astronomical gamma sources. The arrival direction of air showers is reconstructed thanks to the times measured by the pixels of the detector. Therefore, the timing calibration of the detector pixels is crucial in order to get the best angular resolution and pointing accuracy. Because of the large number of pixels a hardware timing calibration is practically impossible. Therefore an off-line software calibration has been adopted. Here, the details of the procedure and the results are presented. (C) 2008 Elsevier B.V. All rights reserved.
Calibration of a camera-projector monochromatic system
2015
Camera–projector systems are increasingly being used in many different applications, including object reconstruction. In recent years, a number of approaches have been proposed to calibrate such devices; in this paper a calibration method is presented which can be used with monochromatic systems. The method is based on open-source code, makes use of planar calibration patterns, is fully automatic, easy to use and fast. Additionally, no initial information regarding the camera interior orientation is needed, and both sensors (camera and projector) are fully calibrated during the process. The method is validated by a series of tests, where root mean square errors (RMSEs) in image space are ke…
Low Energy Protons at RADEF - Application to Advanced eSRAMs
2014
A low energy proton facility has been developed at RADEF, Jyvskyl, Finland. The proton energy selection, calibration and dosimetry are described. The first experiment with external users was performed using two memory test vehicles fabricated with 28 nm technology. Examples of single event upset measurements in the test vehicles embedded SRAMs (eSRAMs) as a function of proton energy are provided.