Currents Distribution During a Fault in an MV Network: Methods and Measurements

2016

When a single line to ground fault happens on the MV side of a HV/MV system, only a small portion of the fault current is injected into the ground by the ground-grid of the faulty substation. In fact the fault current is distributed between grounding electrodes and MV cables sheaths. In systems with isolated neutral or with resonant earthing this may be sufficient to provide safety from electric shock. Experimental measurements were performed on a real MV distribution network: a real single line to ground fault was made and fault currents were measured in the faulty substation and in four neighboring substations. In this paper the problem of fault current distribution is introduced, the tes…

EngineeringDistribution (number theory)020209 energyGlobal earthing system02 engineering and technologyglobal earthing systemsFault (power engineering)Industrial and Manufacturing EngineeringFault current limiter0202 electrical engineering electronic engineering information engineeringmedicineCurrent distributionElectrical and Electronic EngineeringElectrical conductorsingle line to ground faultglobal earthing systems (GESs)Current distribution electrical safety global earthing systems (GESs) grounding power distribution faults power system faults single line to ground fault (SLGF)business.industryGroundElectric shockElectrical engineeringpower system faultsgroundingmedicine.diseaseGridSingle linecurrent distribution; electrical safety; global earthing systems; grounding; power distribution faults; power system faults; single line to ground fault; control and systems engineering; industrial and manufacturing engineering; electrical and electronic engineeringSettore ING-IND/33 - Sistemi Elettrici Per L'EnergiaSettore ING-IND/31 - ElettrotecnicaPower system faultControl and Systems Engineeringsingle line to ground fault (SLGF)power distribution faultselectrical safetybusinessCurrent distribution; electrical safety; global earthing systems (GESs); grounding; power distribution faults; power system faults; single line to ground fault (SLGF); Control and Systems Engineering; Industrial and Manufacturing Engineering; Electrical and Electronic EngineeringPower distribution fault
researchProduct

Arc Fault Detection Method Based on CZT Low-Frequency Harmonic Current Analysis

2017

This paper presents a method for the detection of series arc faults in electrical circuits, which has been developed starting from an experimental characterization of the arc fault phenomenon and an arcing current study in several test conditions. Starting from this, the authors have found that is it possible to suitably detect arc faults by means of a high-resolution low-frequency harmonic analysis of current signal, based on chirp zeta transform, and a proper set of indicators. The proposed method effectiveness is shown by means of experimental tests, which were carried in both arcing and nonarcing conditions and in the presence of different loads, chosen according to the UL 1699 standard…

Engineeringarc fault detection020209 energyseries arcsArc-fault circuit interrupter02 engineering and technologyUL 1699Fault detection and isolationlaw.inventionHarmonic analysisElectric arcarc fault circuit interrupter (AFCI)Arc dischargeslawArc discharges arc fault circuit interrupter (AFCI) arc fault detection electrical safety fault diagnosis home protection interrupters power system harmonics power system measurements series arcs UL 1699Fault current limiterhome protection0202 electrical engineering electronic engineering information engineeringElectronic engineeringElectrical and Electronic EngineeringInstrumentationpower system harmonicsinterruptersbusiness.industry020208 electrical & electronic engineeringfault diagnosispower system measurementsFault indicatorElectrical networkHarmonicelectrical safetybusinessSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Circuit proposals for high-voltage latching current limiters

2019

This work discusses some ideas to adapt existing low voltage Latching Current Limiter (LCL) circuits to high voltage operation to provide a basis for future designs. Component selection, driver and ancillary power supply are key issues discussed which eventually provides a high-voltage LCL proposal. Experimental validation of two different prototypes (380Vdc and 1kVdc) is included as well as some digital techniques to enhance LCL capabilities.

Current limitingWork (electrical)Computer scienceComponent (UML)LimiterElectronic engineeringHigh voltageLow voltagePower (physics)Electronic circuit2019 European Space Power Conference (ESPC)
researchProduct

FAST EDGE-FILTERED IMAGE UPSAMPLING.

2011

We present a novel edge preserved interpolation scheme for fast upsampling of natural images. The proposed piecewise hyperbolic operator uses a slope-limiter function that conveniently lends itself to higher-order approximations and is responsible for restricting spatial oscillations arising due to the edges and sharp details in the image. As a consequence the upsampled image not only exhibits enhanced edges, and discontinuities across boundaries, but also preserves smoothly varying features in images. Experimental results show an improvement in the PSNR compared to typical cubic, and spline-based interpolation approaches.

business.industryIterative reconstructionClassification of discontinuitiesEdge detectionArticleUpsamplingSpline (mathematics)PiecewiseComputer visionArtificial intelligenceFlux limiterbusinessImage resolutionMathematicsProceedings. International Conference on Image Processing
researchProduct

Nuclear Analysis of an ITER Blanket Module

2013

ITER blanket system is the reactor’s plasma-facing component, it is mainly devoted to provide the thermal and nuclear shielding of the Vacuum Vessel and external ITER components, being intended also to act as plasma limiter. It consists of 440 individual modules which are located in the inboard, upper and outboard regions of the reactor. In this paper attention has been focused on to a single outboard blanket module located in the equatorial zone, whose nuclear response under irradiation has been investigated following a numerical approach based on the Monte Carlo method and adopting the MCNP5 code. The main features of this blanket module nuclear behaviour have been determined, paying part…

Nuclear and High Energy PhysicsNeutron transportMaterials sciencebusiness.industryNuclear engineeringNeutronics Blanket ITER Monte Carlo methodBlanketNuclear powerNuclear physicsNuclear Energy and EngineeringNeutron fluxElectromagnetic shieldingLimiterNuclear fusionNeutronbusinessSettore ING-IND/19 - Impianti Nucleari
researchProduct

Current and Voltage Behaviour During a Fault in a HV/MV System: Methods and Measurements

2015

When a single line to ground fault happens on the MV side of a HV/MV system, only a small portion of the fault current is injected into the ground by the ground-grid of the faulty substation. In fact the fault current is distributed between grounding electrodes and MV cables sheaths. In systems with isolated neutral or with resonant earthing this may be sufficient to provide safety from electric shock. Experimental measurements were performed on a real MV distribution network: a real single line to ground fault was made and fault currents were measured in the faulty substation and in four neighbouring substations. In this paper the problem of fault current distribution is introduced, the te…

Engineeringelectrical and electronic engineeringGlobal earthing systemCurrent distribution; Electrical safety; Global earthing systems; grounding; Power distribution faults; Single line to ground faultHardware_PERFORMANCEANDRELIABILITYFault (power engineering)Fault current limiterElectronic engineeringmedicineGlobal earthing systemscurrent distribution; electrical safety; global earthing systems; grounding; power distribution faults; single line to ground fault; electrical and electronic engineering; energy engineering and power technologyenergy engineering and power technologyCurrent distributionPower distribution faultsElectrical safetySingle line to ground faultElectric shockGroundbusiness.industryElectrical engineeringgroundingSingle linemedicine.diseaseEarthing systemSettore ING-IND/33 - Sistemi Elettrici Per L'EnergiaSettore ING-IND/31 - ElettrotecnicaCurrent (fluid)businessPower distribution faultVoltage
researchProduct

A fiber-based limiter at 170 Gbit/s for all-optical regeneration

2009

We report the numerical and experimental studies of a spectrally filtered fiber-based optical limiter at 170 Gbit/s. The device, including less than 1 km-long of highly nonlinear optical fiber and a 3 nm-width filter, exhibits good performance at an average input power of 14.5 dBm. No power penalty has been observed and a strong robustness against optical noise has been demonstrated.

Multi-mode optical fiberMaterials scienceOptical fiberbusiness.industrydBmPhysics::OpticsNonlinear opticslaw.inventionRobustness (computer science)lawLimiterOptoelectronicsDispersion-shifted fiberTelecommunicationsbusinessOptical filter2009 International Conference on Advanced Technologies for Communications
researchProduct

Analysis of Torque Developed in Axial Flux, Single-Phase Brushless DC Motor With Salient-Pole Stator

2004

An analysis of the torque developed by a single-phase disc brushless permanent magnet motor with salient-pole stator is presented. The machine represents a new family of brushless disc motors with the starting torque issue appearing to be most challenging. To produce a starting torque, the permanent magnets on one of the rotor discs are distributed nonuniformly. However, this significantly distorts a shape of the cogging torque versus rotational angle characteristic which, in turn, affects a waveform of the overall torque. A three-dimensional (3-D) finite-element model is used for the purpose of determining of angular variations of the torque developed by the motor. To find how the torque v…

PhysicsStall torqueTorque motorCogging torqueEnergy Engineering and Power TechnologyControl engineeringQuantitative Biology::Subcellular ProcessesTorque limiterDirect torque controlControl theoryTorque sensorAstrophysics::Earth and Planetary AstrophysicsElectrical and Electronic EngineeringDamping torqueSynchronous motorIEEE Transactions on Energy Conversion
researchProduct

Performance Improvement of Grid-Integrated Doubly Fed Induction Generator under Asymmetrical and Symmetrical Faults

2023

The doubly fed induction generator (DFIG)-based wind energy conversion system (WECS) suffers from voltage and frequency fluctuations due to the stochastic nature of wind speed as well as nonlinear loads. Moreover, the high penetration of wind energy into the power grid is a challenge for its smooth operation. Hence, symmetrical faults are most intense, inflicting the stator winding to low voltage, disturbing the low-voltage ride-through (LVRT) functionality of a DFIG. The vector control strategy with proportional–integral (PI) controllers was used to control rotor-side converter (RSC) and grid-side converter (GSC) parameters. During a symmetrical fault, however, a series grid-side converter…

series grid-side converterControl and OptimizationRenewable Energy Sustainability and the EnvironmentEnergy Engineering and Power TechnologyBuilding and Constructiondoubly fed induction generator; wind energy conversion system; point of common coupling; low-voltage ride-through; fault current limiter; series grid-side converterDoubly fed induction generatorlow-voltage ride-throughSettore ING-IND/33 - Sistemi Elettrici Per L'Energiawind energy conversion systempoint of common couplingElectrical and Electronic EngineeringEngineering (miscellaneous)fault current limiterEnergy (miscellaneous)Energies; Volume 16; Issue 8; Pages: 3350
researchProduct

Measuring the isotope effect on the gross beryllium erosion in JET

2022

Abstract The isotope effect, hydrogen (H) versus deuterium (D), on the gross beryllium (Be) erosion yield has been measured in ohmic limiter plasmas in JET tokamak by spectroscopic means. A simplified method to extract the effective sputtering yield from the quotient of the radiances of the D α or D γ and the Be II lines at 527 nm was applied. A clear isotope effect has been found, the erosion yield of D being about a factor of 2 larger compared to H in the whole explored plasma density range. This is in agreement with physical sputtering data obtained with H+ and D+ ion beams and also with material surface computer simulations. The already published contribution of chemically assisted phys…