Search results for "liquid"
showing 10 items of 4351 documents
LC–ESI–FT–MSn Metabolite Profiling of Symphytum officinale L. Roots Leads to Isolation of Comfreyn A, an Unusual Arylnaphthalene Lignan
2020
Preparations of comfrey (Symphytum officinale L.) roots are used topically to reduce inflammation. Comfrey anti-inflammatory and analgesic properties have been proven in clinical studies. However, the bioactive compounds associated with these therapeutic activities are yet to be identified. An LC&ndash
Nitration of cathepsin D enhances its proteolytic activity during mammary gland remodelling after lactation
2009
Proteomic studies in the mammary gland of control lactating and weaned rats have shown that there is an increased pattern of nitrated proteins during weaning when compared with controls. Here we report the novel finding that cathepsin D is nitrated during weaning. The expression and protein levels of this enzyme are increased after 8 h of litter removal and this up-regulation declines 5 days after weaning. However, there is a marked delay in cathepsin D activity since it does not increase until 2 days post-weaning and remains high thereafter. In order to find out whether nitration of cathepsin D regulates its activity, iNOS (inducible nitric oxide synthase)−/− mice were used. The expression…
Rapid determination of baicalin and total baicalein content in Scutellariae radix by ATR-IR and NIR spectroscopy
2013
In this study methods for the quantification of baicalin and total baicalein in Scutellariae radix with near infrared (NIR) spectroscopy and attenuated-total-reflectance mid-infrared (ATR-IR) spectroscopy in hyphenation with multivariate analysis were developed and compared. The reference analysis was performed by high performance liquid chromatography coupled to diode array detection (HPLC-DAD). Different pretreatments like standard normal variate (SNV), multiplicative scatter correction (MSC), first and second derivative Savitzky-Golay were applied on the spectra to optimize the calibrations. A principal component analysis was performed with both spectroscopic methods to distinguish wild …
Pyrocoll, an Antibiotic, Antiparasitic and Antitumor Compound Produced by a Novel Alkaliphilic Streptomyces Strain
2003
A new secondary metabolite was detected in the culture extract of Streptomyces sp. AK 409 by HPLC-diode-array screening. The metabolite was identified as pyrocoll, which is known to be a constituent of cigarette smoke. Pyrocoll is known as a synthetic compound, but until now had not been isolated as a natural product from a microorganism. The compound showed biological activity against various Arthrobacter strains, filamentous fungi, several pathogenic protozoa, and some human tumor cell lines.
Multi-site analytical evaluation of a chemiluminescent magnetic microparticle immunoassay (CMIA) for sirolimus on the Abbott ARCHITECT analyzer.
2009
Objective This study evaluated a new chemiluminescent magnetic microparticle immunoassay (CMIA) for sirolimus on the ARCHITECT analyzer. Design and methods Patient and laboratory proficiency samples were tested at three European sites and one site in the United States. Results The CMIA total %CV's were all < 8% and the Limit of Quantification (LOQ) was < 1.52 ng/mL across the four sites. It cross-reacts to sirolimus metabolites F4 and F5 and showed no hematocrit interference over a range of 25% to 55%. Patient specimen correlations to three LC/MS/MS methods gave R ≥ 0.91 at three sites and mean biases of 14%, 25% and 39%. CMIA patient specimen correlations to the Abbott IMx gave R ≥ 0.94 at…
A noise analyzer for monitoring static electrification current
2005
Abstract This paper presents a static electrification current signal analyzer used for measuring and processing of the variable component of the changes in electrostatic charge that occur on a solid-body/liquid boundary interface. Due to high sensitivity and low uncertainty, the analyzer allows a precise evaluation of the phenomenon generated. The device operates in a spinning-disk system. The tests carried out indicate that it is possible to measure random components which depend, to a large extent, on hydrodynamic conditions and on the properties of the liquid phase. The device can be applied to the testing of transformer oils. It can be also used for measurements of other liquids having …
Spin relaxation in Cu and Al spin conduits
2014
We study the spin relaxation in Al and Cu spin conduits embedded in non-local spin valve nanostructures. Measuring the key spin transport properties, we determine the spin and charge diffusion constants as well as the spin flip time. By varying the temperature, we find that the maximum of the non-local spin resistance change occurs at finite temperatures with a clear difference between Al and Cu. In particular, we find that the maximum of the non-local spin signal in Al is less pronounced and occurs at lower temperatures compared to Cu suggesting that the self-passivating Al surface plays a role. Having fabricated devices with both materials in identical processes, we can attribute the diff…