Search results for "liquid"
showing 10 items of 4351 documents
Analytical capabilities of high performance liquid chromatography – Atmospheric pressure photoionization – Orbitrap mass spectrometry (HPLC-APPI-Orbi…
2015
A new analytical method was established and validated for the analysis of 27 brominated flame retardants (BFRs), including so called "emerging" and "novel" BFRs (EBFRs and NBFRs) in fish samples. High performance liquid chromatography (HPLC) coupled to Orbitrap mass spectrometry (Orbitrap-MS) employing atmospheric pressure photoionization (APPI) interface operated in negative mode was used for the identification/quantitation of contaminants. HPLC-Orbitrap-MS analysis provided a fast separation of selected analytes within 14 min, thus demonstrating a high throughput processing of samples. The developed methodology was tested by intralaboratory validation in terms of recovery, repeatability, …
Adsorbent phases with nanomaterials for in-tube solid-phase microextraction coupled on-line to liquid nanochromatography
2015
Following the present trends in miniaturization, a methodology that combines on-line In-Tube Solid-Phase Microextraction (IT-SPME) with Liquid Nanochromatography (nano-LC) and UV-vis diode array detection (DAD) was developed. This coupling was achieved by using two interconnected valves (i.e. conventional and micro-automatic valves) in the system of injection. As for IT-SPME, different materials, containing in some cases nanostructures or nanoparticles and in other cases polymeric adsorbent phases immobilized on capillary columns, were tested in order to improve extraction efficiencies of organic compounds; diclofenac was selected as the target analyte. Additionally, the transfer time of th…
Procedure for automated background correction in flow systems with infrared spectroscopic detection and changing liquid-phase composition
2009
This paper describes a partial least squares (PLS) based automatic procedure to correct for changes in the spectral contribution of the solvent or solvent mixtures from solute spectra recorded in these solvents. The procedure was developed for successful on-line Fourier transform infrared (FT-IR) detection in gradient high-performance liquid chromatography (HPLC) separations. It requires a reference FT-IR data set containing all possible combinations of the expected variation in solvent composition. Furthermore, a spectral region ( A) in these spectra is required where the solvents show absorption but the analytes do not. This is the case for the system ACN:H2O, an often-applied solvent mi…
In-tube solid-phase microextraction-capillary liquid chromatography as a solution for the screening analysis of organophosphorus pesticides in untrea…
2006
This paper describes a method for the selective screening of organophosphorus pesticides in water. In-tube solid-phase microextraction (SPME) in an open capillary column coupled to capillary liquid chromatography (LC) with UV detection has been used to effect preconcentration, separation and detection of the analytes in the same assembly. For in-tube SPME two capillary columns of the same length and different internal diameters and coating thicknesses have been tested and compared, a 30 cm x 0.25 mm I.D., 0.25 micro m thickness coating column, and a 30 cm x 0.1 mm I.D., 0.1 micro m of coating thickness column. In both columns the coating was 95% dimethylpolysiloxane (PDMS)-5% diphenylpolysi…
Validation of a confirmatory method for the determination of macrolides in liver and kidney animal tissues in accordance with the European Union regu…
2006
Abstract This study proposes a simple multiresidue liquid chromatography–diode array detector (LC–DAD) method capable of determining seven macrolide antibiotics in samples of liver and kidney animals at concentrations lower than those allowed by current legislation. Samples were prepared by homogenizing the tissue with EDTA–McIlvaine's buffer and extracted with an Oasis HLB cartridge. The consumption of organic solvent during extraction was minimum. The analytes were detected by LC–DAD and also by liquid chromatography–mass spectrometry with electrospray ionization (LC–(ESI)MS). The method was specific, stable and robust enough for the required purposes. The DAD method was validated in acco…
o-Phthalaldehyde–N-acetylcysteine polyamine derivatives: formation and stability in solution and in C18 supports
2001
A comparative study of different derivatization procedures has been performed in order to improve the stability of the reaction products o-phthalaldehyde-N-acetylcysteine (OPA-NAC) polyamines. Procedures such as solution derivatization, solution derivatization followed by retention on a packing support, derivatization on different packing supports and on-column derivatization, have been optimized and compared. The degradation rate constant (k) of the derivative was dependent on the procedure used and on the analyte. For the spermine (the most unstable isoindol tested) k was 8 +/- 2 x 10(-2) min(-1) in solution versus 7.7 +/- 1.1 x 10(-4) min(-1) on the (C18) solid support. The results obtai…
Column-switching techniques for high-performance liquid chromatography of drugs in biological samples.
1993
In recent years, an increasing number of publications have demonstrated the potential of column-switching techniques for the chromatographic separation, determination and preparative isolation of analytes from biological matrices. Column-switching systems greatly facilitate drug analysis, by on-line sample clean-up and trace enrichment, or by improving the analytical separative process. In this paper, the main applications of column-switching techniques to drug analysis in biological samples, are reviewed.
Green aspects, developments and perspectives of liquid phase microextraction techniques.
2014
Determination of analytes at trace levels in complex samples (e.g. biological or contaminated water or soils) are often required for the environmental assessment and monitoring as well as for scientific research in the field of environmental pollution. A limited number of analytical techniques are sensitive enough for the direct determination of trace components in samples and, because of that, a preliminary step of the analyte isolation/enrichment prior to analysis is required in many cases. In this work the newest trends and innovations in liquid phase microextraction, like: single-drop microextraction (SDME), hollow fiber liquid-phase microextraction (HF-LPME), and dispersive liquid-liqu…
Environmentally friendly LC for the simultaneous determination of ascorbic acid and its derivatives in skin-whitening cosmetics
2008
Ascorbic acid (AA), also known as vitamin C, is a very popular skin-whitening agent used in cosmetics. However, the use of AA (and also its sodium or magnesium salts) in cosmetic products is limited owing to its labile oxidative properties. In order to avoid its early degradation, different derivatives have been designed, such as ascorbyl phosphate (APH; as magnesium or sodium salts) and ascorbyl palmitate (AP), and more recently the ascorbyl glucoside (AG). Bearing in mind that all these chemicals in skin-whitening cosmetic products must be determined in order to control the efficacy of such products, this paper focuses on developing a wide-ranging LC analytical method able to determine th…
Development and validation of a fast and sensitive chromatographic assay for all-trans-retinol and tocopherols in human serum and plasma using liquid…
2002
A sensitive HPLC assay for all-trans-retinol, alpha-tocopherol, and gamma-tocopherols in human serum and plasma is reported. Sample preparation is performed in one step and involves precipitation of proteins and extraction of lipids with two volumes of an ethanol-chloroform mixture (3:1, v/v) without I.S. addition. After removal of the precipitated protein, 20 microl aliquots of the supernatant (equivalent to 6.7 microl of serum or plasma) were injected into the HPLC system and analyzed using fluorometric detection. RP-HPLC was performed using a C(18) S3 ODS2 column with a methanol-water step gradient (97:3 to 100) at 1.0 ml/min. The quantification limit expressed as nanograms of analyte pe…