Search results for "liquid"

showing 10 items of 4351 documents

Review: Determination of Vitamin D in Dairy Products by High Performance Liquid Chromatography

2005

This work reviews the methods used for the determination of vitamin D in some dairy products (milk and infant formulas) by high performance liquid chromatography (HPLC). The low vitamin D contents and the presence of interfering compounds require sample treatment and purification of the extract. The advantages and drawbacks of hot and cold saponification, direct extraction and different types of extract purification are also discussed, taking into account the lack of vitamin D stability by heating, exposure to light and oxidation. With respect to chromatographic determination, the mode (normal or reverse phase), type of column (microcolumn or conventional) and detection system (UV, electro…

Chromatography010405 organic chemistryChemistryGeneral Chemical Engineering010401 analytical chemistryExtraction (chemistry)Vitamina dMass spectrometry01 natural sciencesHigh-performance liquid chromatographyIndustrial and Manufacturing Engineering0104 chemical sciencesInfant formulaBy-productVitamin D and neurologySaponificationFood ScienceFood Science and Technology International
researchProduct

Eucalyptol-based green extraction of brown alga Zonaria tournefortii

2018

Abstract A green extraction method, based on the use of 1,8-cineole (eucalyptol) as biosolvent, has been developed to prepare crude extracts from the brown alga Zonaria tournefortii characterized by chemical composition, particularly dominated by phenolic compounds derived from phloroglucinol. The main advantage of the developed technique are the recovery of eucalyptol, based on multistep liquid-liquid extraction with distilled water, followed by centrifugation and elimination of the aqueous phase, and the complete recycling of biosolvent by steam distillation. A comparative study between the proposed green extract and the conventional extract, prepared by solvent maceration using the mixtu…

Chromatography010405 organic chemistryDPPH010401 analytical chemistryExtraction (chemistry)Aqueous two-phase systemPharmaceutical ScienceManagement Monitoring Policy and Law01 natural sciencesPollutionHigh-performance liquid chromatography0104 chemical scienceslaw.inventionSteam distillationchemistry.chemical_compoundEucalyptolchemistrylawMaceration (wine)Environmental ChemistryPhenolsSustainable Chemistry and Pharmacy
researchProduct

Comparison of photodiode array, evaporative light scattering, and single-quadrupole mass spectrometric detection methods for the UPLC analysis of pyr…

2017

ABSTRACTIt is important to analyze pyrolysis liquids to evaluate the yield of valuable products as well as unfavorable by-products. This work focuses on choosing detectors for reversed-phase ultra high-performance liquid chromatography analysis of pyrolysis liquids. The linearity, sensitivity, precision, and recovery of photodiode array (PDA) detector, single-quadrupole mass spectrometer (MS), and evaporative light scattering (ELS) detector were compared for the quantitative determination of several typical compounds found in pyrolysis liquids. PDA and MS detectors were found to be suitable for the quantification of furans and phenol derivatives (furfural, vanillin, syringol), but sugars an…

Chromatography010405 organic chemistryLevoglucosan010401 analytical chemistryClinical BiochemistrySyringolAnalytical chemistryPharmaceutical ScienceMass spectrometry01 natural sciencesBiochemistryHigh-performance liquid chromatographyLight scattering0104 chemical sciencesAnalytical ChemistryPhotodiodelaw.inventionchemistry.chemical_compoundchemistryChromatography detectorlawPyrolysisJournal of Liquid Chromatography & Related Technologies
researchProduct

Application of point-to-point matching algorithms for background correction in on-line liquid chromatography–Fourier transform infrared spectrometry …

2009

A new background correction method for the on-line coupling of gradient liquid chromatography and Fourier transform infrared spectrometry has been developed. It is based on the use of a point-to-point matching algorithm that compares the absorption spectra of the sample data set with those of a previously recorded reference data set in order to select an appropriate reference spectrum. The spectral range used for the point-to-point comparison is selected with minimal user-interaction, thus facilitating considerably the application of the whole method. The background correction method has been successfully tested on a chromatographic separation of four nitrophenols running acetonitrile (0.08…

ChromatographyAbsorption spectroscopyChemistryReference data (financial markets)Analytical chemistryInfrared spectroscopyFourier transform spectroscopyAnalytical ChemistryNitrophenolschemistry.chemical_compoundSpectroscopy Fourier Transform InfraredBackground Correction MethodFourier transform infrared spectroscopySpectroscopyAcetonitrileAlgorithmsChromatography LiquidTalanta
researchProduct

Retention mechanisms for basic drugs in the submicellar and micellar reversed-phase liquid chromatographic modes.

2008

The reversed-phase liquid chromatographic (RPLC) behavior (retention, elution strength, selectivity, efficiency, and peak asymmetry) for a group of basic drugs (beta-blockers), with mobile phases containing the anionic surfactant sodium dodecyl sulfate (SDS) and acetonitrile, revealed different separation environments, depending on the concentrations of both modifiers: hydro-organic, submicellar at low surfactant concentration and high concentration of organic solvent, micellar, and submicellar at high concentration of both surfactant and organic solvent. In the surfactant-mediated modes, the anionic surfactant layer adsorbed on the stationary phase interacts strongly with the positively ch…

ChromatographyAcetonitrilesElutionSodium Dodecyl SulfateReversed-phase chromatographyMicelleAnalytical Chemistrychemistry.chemical_compoundPulmonary surfactantchemistryPharmaceutical PreparationsPhase (matter)SolventsSolubilitySodium dodecyl sulfateAcetonitrileMicellesChromatography LiquidAnalytical chemistry
researchProduct

An approach to evaluate the information in chromatographic fingerprints: Application to the optimisation of the extraction and conservation condition…

2015

A new approach is reported for high-performance liquid chromatography to measure the level of information in fingerprints. For this purpose, the concept of peak prominence, which is the protruding part of each visible peak with regard to the valleys that delimit it, was used. The peaks in the fingerprints are ranked according to the areas of the peak prominences, and a threshold is established to discriminate between the significant peaks and those that are irreproducible. The approach was applied to evaluate the impact of several extraction conditions (solvent nature and composition, time and temperature of the treatment, amount of sample, and time and temperature of conservation of the ex…

ChromatographyAcetonitrilesPlants MedicinalTeaPlant ExtractsOrganic ChemistryExtraction (chemistry)Analytical chemistryGeneral MedicineReversed-phase chromatographyGreen teaBiochemistryChemistry Techniques AnalyticalAnalytical ChemistryLinear gradientSolventchemistry.chemical_compoundchemistrySolventsMedicinal herbsMethanolAcetonitrileChromatography High Pressure LiquidJournal of chromatography. A
researchProduct

Performance of micellar mobile phases in reversed-phase chromatography for the analysis of pharmaceuticals containing beta-blockers and other antihyp…

1996

A rapid and simple reversed-phase micellar liquid chromatographic procedure for the simultaneous determination of the beta-blockers atenolol, metoprolol and oxprenolol, the diuretics amiloride, bendroflumethiazide, chlorthalidone and hydrochlorothiazide and the vasodilator hydralazine in pharmaceuticals, is proposed. An interpretive optimization procedure, which uses the chromatographic data for only five mobile phases, was applied to select a suitable micellar mobile phase. A comparative study was also made of the performance of micellar and aqueous-organic mobile phases in the analysis of pharmaceuticals that combine beta-blockers and diuretics. The determination of all the drugs could be…

ChromatographyAdrenergic beta-AntagonistsReversed-phase chromatographyAtenololHydralazineBiochemistryHigh-performance liquid chromatographyDosage formAnalytical Chemistrychemistry.chemical_compoundHydrochlorothiazidechemistryOxprenololElectrochemistrymedicineSolventsEnvironmental ChemistryBendroflumethiazideSodium dodecyl sulfateDiureticsSpectroscopyAntihypertensive AgentsChromatography High Pressure LiquidMicellesmedicine.drugThe Analyst
researchProduct

Comparative HPLC/ESI-MS and HPLC/DAD study of different populations of cultivated, wild and commercial Gentiana lutea L.

2015

The root of Gentiana lutea L., famous for its bitter properties, is often used in alcoholic bitter beverages, food products and traditional medicine to stimulate the appetite and improve digestion. This study presents a new, fast, and accurate HPLC method using HPLC/ESI-MS and HPLC/DAD for simultaneous analysis of iridoids (loganic acid), secoiridoids (gentiopicroside, sweroside, swertiamarin, amarogentin) and xanthones (isogentisin) in different populations of G.lutea L., cultivated in the Monti Sibillini National Park, obtained wild there, or purchased commercially. Comparison of HPLC/ESI-MS and HPLC/DAD indicated that HPLC/ESI-MS is more sensitive, reliable and selective. Analysis of twe…

ChromatographyAlcoholic BeveragesXanthonesIridoid GlucosidesGeneral MedicineAmarogentinBiologyHigh-performance liquid chromatographyPlant RootsMass SpectrometryAnalytical Chemistrychemistry.chemical_compoundHplc esi msLoganic acidchemistryPyronesFood productsTasteIridoidsGentianaGentiana luteaHplc methodHplc dadChromatography High Pressure LiquidFood ScienceFood chemistry
researchProduct

Chiral determination of amphetamine and related compounds using chloroformates for derivatization and high-performance liquid chromatography

1999

The enantiomeric determination of amphetamine and various amphetamine-type compounds by liquid chromatography after chiral derivatization with 9-fluorenylmethyl chloroformate-L-proline (FMOC-L-Pro) is reported. The results obtained were compared with those achieved after achiral derivatization with 9-fluorenylmethyl chloroformate and subsequent separation of the derivatives on a beta-cyclodextrin chiral stationary phase. Conditions for the derivatization of amphetamines with FMOC-L-Pro were investigated, including the effect of the derivatization reagent concentration, pH and reaction time, using amphetamine, ephedrine and pseudoephedrine as model compounds. On the basis of these studies, p…

ChromatographyAmphetaminesStereoisomerismChloroformatePseudoephedrineSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundchemistryReagentElectrochemistrymedicineEnvironmental ChemistryOrganic chemistryCentral Nervous System StimulantsEnantiomerEphedrineDerivatizationQuantitative analysis (chemistry)Chromatography High Pressure LiquidSpectroscopymedicine.drugThe Analyst
researchProduct

Study of liquid–liquid extraction of ethanol + water azeotropic mixtures using two imidazolium-based ionic liquids

2018

Abstract The present work was focused on the study of two imidazolium-based ionic liquids (ILs) as solvents in liquid–liquid extraction of ethanol from aqueous mixtures. With this aim, the experimental liquid–liquid equilibria (LLE) data of water (1) + ethanol (2) + 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([emim][Tf2N]) (3) and water (1) + ethanol (2) + 1-hexyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([hmim][Tf2N]) (4) systems were obtained at different temperatures: 283.2, 303.2, and 323.2 K, in order to check the influence of temperature. The results were correlated by non-random two-liquid (NRTL) and universal quasichemical (UNIQUAC) models with good c…

ChromatographyAqueous solutionUNIQUAC02 engineering and technology021001 nanoscience & nanotechnologyAtomic and Molecular Physics and Opticschemistry.chemical_compound020401 chemical engineeringchemistryLiquid–liquid extractionIonic liquidNon-random two-liquid modelPhysical chemistryGeneral Materials Science0204 chemical engineeringPhysical and Theoretical Chemistry0210 nano-technologyImideSelectivityTernary operationThe Journal of Chemical Thermodynamics
researchProduct