Evaluation of advanced silica packings for the separation of biopolymers by high-performance liquid chromatography

1987

Following previous studies of the use of non-porous monodisperse 1.5-microns n-octyl- and n-octadecyl-bonded silicas in gradient elution of proteins, this work was aimed at elucidating further the properties of this novel column material for peptide and protein separations in comparison with wide-pore silicas. First, it is demonstrated that with short columns (e.g., 35 X 8 mm I.D.) packed with these non-porous reversed-phase materials, mixtures of small peptides and mixtures of proteins can be very efficiently resolved. When the chain length of the bonded ligand was varied, the retention of a test set of proteins in gradient elution followed the ligand sequence C18 greater than C8 approxima…

ChromatographyChemistryElutionDiffusionOrganic ChemistryDispersityGeneral MedicineMole fractionBiochemistryHigh-performance liquid chromatographyCapacity factorAnalytical ChemistryPhase (matter)SelectivityJournal of Chromatography A
researchProduct

Near-critical carbon dioxide extraction and liquid chromatography determination of UV filters in solid cosmetic samples: A green analytical procedure

2005

Near-critical carbon dioxide extraction of four UV filters used as sunscreens in lipsticks and makeup formulations is reported. Extraction parameters were optimized. Efficient recoveries were obtained after 15 min of dynamic extraction with a 80:20 CO2/ethanol mixture at 300 atm and 54 degrees C, using a 1.8 mL/min flow rate. Extracts were collected in ethanol, and appropriately diluted with ethanol and 1% acetic acid to obtain a 70:30 v/v ethanol/1% acetic acid solution. The four UV filters were determined by LC with gradient elution using ethanol/1% acetic acid as mobile phase. The accuracy of the analytical procedure was estimated by comparing the results with those obtained by methods b…

ChromatographyChemistryElutionExtraction (chemistry)Supercritical fluid extractionUV filterFiltration and SeparationCosmeticsCarbon DioxideHigh-performance liquid chromatographySupercritical fluidAnalytical ChemistryAcetic acidchemistry.chemical_compoundSample preparationSunscreening AgentsChromatography LiquidJournal of Separation Science
researchProduct

Liquid chromatography and characterization of ether-functionalized imidazolium ionic liquids on mixed-mode reversed-phase/cation exchange stationary …

2010

Abstract A new series [CnOmmim]Cl of imidazolium cation-based ionic liquids (ILs), with an ether functional group on the alkyl side-chain, has been prepared. The possibility of analyzing the ionic liquids by high performance liquid chromatography (HPLC) was investigated on mixed-mode reversed/cation exchange stationary phase with the aqueous-acetonitrile mobile phase. Elution parameters, such as retention factor, selectivity and column efficiency, were studied as functions of mobile phase composition and pH. The ILs were characterized by elemental analysis, and infrared, UV and 1H, 13C NMR spectroscopy.

ChromatographyChemistryElutionGeneral Chemical EngineeringHydrophilic interaction chromatographyIon chromatographyAnalytical chemistryEtherGeneral ChemistryReversed-phase chromatographyHigh-performance liquid chromatographychemistry.chemical_compoundPhase (matter)Ionic liquidComptes Rendus Chimie
researchProduct

Univariate method for background correction in liquid chromatography–Fourier transform infrared spectrometry

2007

An univariate method is proposed for background correction in on-line gradient liquid chromatography-Fourier transform infrared (LC-FTIR) spectrometry using acetonitrile:water as mobile phase components. The method is based on the calculation of the ratio of absorbances (AR) at two characteristic wavenumbers for each spectrum. This parameter is subsequently used to locate the most appropriated eluent spectrum within a reference spectra matrix (RSM) to be subtracted from each spectrum included in the sample chromatogram. To correct minor changes in eluent spectra intensity during the elution of analytes, a correction factor (Kf), defined as the ratio of the absorbance of the sample and the s…

ChromatographyChemistryElutionOrganic ChemistryAnalytical chemistryInfrared spectroscopyGeneral MedicineReference StandardsMass spectrometryBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryMatrix (chemical analysis)ChemometricsAbsorbanceDiuronSpectroscopy Fourier Transform InfraredAtrazineFourier transform infrared spectroscopyChromatography LiquidJournal of Chromatography A
researchProduct

Extraction of clenbuterol from calf urine using a molecularly imprinted polymer followed by quantitation by high-performance liquid chromatography wi…

2002

A method for the extraction of clenbuterol from calf urine samples using a molecularly imprinted polymer (MIP) has been developed. The aim was that the final extracts from the MIP should allow quantitation of clenbuterol down to 0.5 ng/mL urine using HPLC with UV detection. The MIP was produced using brombuterol as a template and the selectivity of the MIP, for clenbuterol, was tested against a non-imprinted polymer (produced without template) and was found to be high. After loading of 5 mL diluted centrifuged urine, selective binding was established in acetonitrile-acetic acid (98:2). For further elution of interferences, 0.5 M ammonium acetate buffer pH 5 and 70% acetonitrile in water was…

ChromatographyChemistryElutionOrganic ChemistryExtraction (chemistry)Molecularly imprinted polymerReproducibility of ResultsGeneral MedicineReversed-phase chromatographyReference StandardsSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryClenbuterolmedicineAnimalsCattleClenbuterolSpectrophotometry UltravioletSample preparationSolid phase extractionAdrenergic alpha-AgonistsChromatography High Pressure Liquidmedicine.drugJournal of Chromatography A
researchProduct

Liquid chromatographic procedure for the evaluation of β-blockers in pharmaceuticals using hybrid micellar mobile phases

1997

Abstract A reversed-phase chromatographic procedure with a micellar eluent is proposed for the determination of several β-blockers (acebutolol, atenolol, carteolol, celiprolol, labetalol, metoprolol, nadolol, oxprenolol, propranolol, and timolol) in pharmaceutical formulations (tablets, capsules, and ophthalamic solutions). A study is shown on the chromatographic behaviour of these drugs with mobile phases containing sodium dodecyl sulphate (0.075–0.15 M ) and propanol (0–15%, v/v), at different pH values (3–7). The excellent correlation between log of the octanol-water partition coefficient and log of capacity factor, for the ten drugs in mobile phases of SDS and propanol, suggested that t…

ChromatographyChemistryElutionOrganic ChemistryGeneral MedicineReversed-phase chromatographyBiochemistryHigh-performance liquid chromatographyCapacity factorDosage formAnalytical ChemistryPartition coefficientPropanolchemistry.chemical_compoundOxprenololmedicinemedicine.drugJournal of Chromatography A
researchProduct

Solid-Phase Extraction Techniques for Assay of Diuretics in Human Urine Samples

1991

Abstract Solid-phase extraction techniques were evaluated for the treatment of urine samples in the analysis of diuretics before injection into an HP-Hypersyl ODS-C18 column. Six different reversed-phase extraction columns were tested, and the results obtained are compared with those obtained in a classical liquid-liquid extraction with ethyl acetate. The solid-phase extraction procedures are the best overall choice for all the diuretics tested, due to their versatility, the minor time-consuming, and the good recovery percentages obtained. C18 and C8 packings give the highest recoveries for a majority of the diuretics studied. However, CH or PH columns, due to their greater selectivity, can…

ChromatographyChemistryElutionmedicine.medical_treatmentExtraction (chemistry)Ethyl acetateHigh-performance liquid chromatographyMatrix (chemical analysis)chemistry.chemical_compoundmedicineMolecular MedicineSolid phase extractionDiureticThiazidemedicine.drugJournal of Liquid Chromatography
researchProduct

Green Analytical Chemistry

2021

ChromatographyChemistryExtraction (chemistry)010401 analytical chemistryAnalytical chemistryAnalytical Chemistry (journal)02 engineering and technology010402 general chemistry021001 nanoscience & nanotechnology01 natural sciences0104 chemical sciencesLiquid–liquid extractionGreen metricsSolid phase extraction0210 nano-technology
researchProduct

Supported liquid membrane extraction of glyphosate metabolites

2001

Use of the supported liquid membrane (SLM) technique for (aminomethyl)phosphonic acid (AMPA) extraction is presented. For the extraction of this analyte a suitable SLM system involves a liquid membrane containing Aliquat 336 – a cationic carrier that facilitates AMPA transport. The extraction of this compound, as in the case of glyphosate, is dependent on the donor phase pH and the concentration and type of counter-ion in the acceptor phase, although some differences are also observed. In both cases the transport mechanism is counter-coupled transport in which the driving force of mass transport over the membrane is created by the gradient of chloride anions from the acceptor to donor phase.

ChromatographyChemistryExtraction (chemistry)Filtration and SeparationAliquat 336ChlorideAcceptorAnalytical Chemistrychemistry.chemical_compoundMembraneLiquid–liquid extractionMass transferPhase (matter)medicinemedicine.drugJournal of Separation Science
researchProduct

Determination of tetracyclines in multi-specie animal tissues by pressurized liquid extraction and liquid chromatography–tandem mass spectrometry

2009

Abstract A specific, sensitive and robust pressurized liquid extraction (PLE) and liquid chromatography tandem mass spectrometry (LC–MS/MS) method for determining tetracycline, chlortetracycline, oxytetracycline and doxycycline in bovine, swine, poultry and lamb muscle tissues is presented. PLE was performed using an ASE ® 200 from Dionex and water as extractant, followed by solid-phase extraction (SPE) using an Oasis HLB cartridge. The method was validated for beef, chicken, pork and lamb meat in compliance with the requirements set by Commission Decision, 2002/657/EC [Commission Decision 2002/657/EC (2002). Implementing Council Directive 96/23/EC concerning the performance of analytical m…

ChromatographyChemistryExtraction (chemistry)General MedicineOxytetracyclineMass spectrometryAnalytical ChemistryLiquid chromatography–mass spectrometrymedicinemedia_common.cataloged_instanceSample preparationSolid phase extractionEuropean unionQuantitative analysis (chemistry)Food Sciencemedicine.drugmedia_commonFood Chemistry