Search results for "luminescence."

showing 10 items of 1568 documents

White-light phosphorescence emission from a single molecule: application to OLED.

2009

A simple mononuclear cyclometallated iridium(III) complex exhibits white photo- and electro- luminescence in the wavelength range from 440 to 800 nm, which originates from a single emitting excited state of mixed character. Bolink Henk, Henk.Bolink@uv.es ; Coronado Miralles, Eugenio, Eugenio.Coronado@uv.es

DesignLuminescenceUNESCO::QUÍMICAAb initioColorchemistry.chemical_elementEfficiency010402 general chemistryPhotochemistry:QUÍMICA [UNESCO]01 natural sciencesCatalysisCopolymerIridium ComplexesMaterials ChemistryOLEDMoleculeIridiumDiodeEmitting DevicesMononuclear cyclometallated iridiumPhosphorescence010405 organic chemistryChemistrybusiness.industryUNESCO::QUÍMICA::Química analíticaMetals and AlloysAb-InitioGeneral ChemistryDiodes0104 chemical sciences3. Good healthSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsBlueOLEDExcited stateGreen:QUÍMICA::Química analítica [UNESCO]Ceramics and CompositesOptoelectronicsMononuclear cyclometallated iridium ; Luminescence ; Phosphorescence ; OLEDLuminescencePhosphorescencebusinessChemical communications (Cambridge, England)
researchProduct

New flow-multicommutation method for the photo-chemiluminometric determination of the carbamate pesticide asulam

2004

This paper deals with a straightforward automated method for the determination of asulam in water based on the use of a flow manifold including three computer-controlled solenoid valves. The method involves irradiating on an aqueous solution of asulam in glycine buffer at pH 8.3 with UV light during 90 s, then follows the oxidation with potassium permanganate in a sulphuric medium and chemiluminescence-based detection of the resulting photoproducts. The limit of detection thus achieved is 40 mug l(-1). The detector response is linear up to a 5 mg l(-1) asulam concentration and the throughput is 30 samples h(-1). In parallel tests, oxidation with alkaline ferricyanide was also assessed and t…

Detection limitChemiluminescenceChromatographyAqueous solutionSolenoid valvesBiochemistryAnalytical Chemistrylaw.inventionchemistry.chemical_compoundPotassium permanganateAsulamchemistrylawMulticommutationReagentPhotodegradationQUIMICA ANALITICAEnvironmental ChemistryAsulamFerricyanidePhotodegradationSpectroscopyChemiluminescenceAnalytica Chimica Acta
researchProduct

A tandem-flow assembly for the chemiluminometric determination of hydroquinone

2003

A direct chemiluminescent procedure for determination of hydroquinone based on the emergent flow methodology known as multicommutation or tandem-flow is presented for first time. The manifold was based on a set of three channels and three solenoid valves; and, the determination was performed at 60degreesC and at flow-rate of 7.5 ml min(-1). The complete cycle lasted 35 s, which resulted in a sample flow trough of 103 h(-1). The chemical process was the hydroquinone oxidation with the system sulphuric acid-potassium permanganate; and the light emission was clearly enhanced by the presence of quinine sulphate and benzalkonium chloride reaching a detection limit of 30 Rg l(-1). The dynamic int…

Detection limitChemiluminescenceChromatographyHydroquinoneHydroquinonePermanganateAnalytical chemistrySulfuric acidAnalytical Chemistrylaw.inventionchemistry.chemical_compoundBenzalkonium chloridePotassium permanganatechemistryEnvironmental sampleslawTandem-flowQUIMICA ANALITICAmedicinePharmaceuticalsLight emissionChemiluminescencemedicine.drugTalanta
researchProduct

The natural compound chrysosplenol-D is a novel, ultrasensitive optical sensor for detection of Cu(II)

2020

Abstract Herein, we introduce a novel, ultrasensitive optical sensor for determination of Cu(II) ions over the concentration range of 0 to 1 μM Cu(II). The optical sensor is based on the natural molecule chrysosplenol-D (Chp-D) extracted from the flowering plant Chiliadenus montanus (Vahl.) Brullo. Free Chp-D emits fluorescence at 566 nm when excited at 292 nm. Chp-D chelates Cu(II) ions to form a 1:1 (metal:ligand) complex, which quenches the fluorescence emission peak of the free probe at 566 nm. “Turn-off” luminescence could be easily determined and provided distinct proof of the chelation of Cu(II) ions by Chp-D. This novel optical sensor offers a considerable fluorescence mechanism (ch…

Detection limitChemistryAnalytical chemistry02 engineering and technology010402 general chemistry021001 nanoscience & nanotechnologyCondensed Matter PhysicsCharge-transfer complex01 natural sciencesFluorescenceBinding constantAtomic and Molecular Physics and Optics0104 chemical sciencesElectronic Optical and Magnetic Materialssymbols.namesakeLinear rangeStokes shiftMaterials ChemistrysymbolsMoleculePhysical and Theoretical Chemistry0210 nano-technologyLuminescenceSpectroscopyJournal of Molecular Liquids
researchProduct

A portable and low cost equipment for flow injection chemiluminescence measurements.

2004

A compact, reliable and low cost flow injection chemiluminescence system is described. The flow system consists of a set of solenoid micro-pumps that can dispense reproductive micro-volumes of solutions. The luminometer was based on a coiled cell constructed from polyethylene tubing that was sandwiched between two large area photodiodes. The whole equipment costs about US$ 750 and weights ca. 3 kg. Equipment performance was evaluated by measuring low concentrations of hydrogen peroxide by oxidation of luminol and for the determination of ammonium, based on its inhibition of the luminescence provided by the reaction of luminol and sodium hypochlorite. Linear responses were achieved within 1.…

Detection limitChemistryAnalytical chemistryHypochloriteAnalytical ChemistryLuminollaw.inventionchemistry.chemical_compoundlawReagentSodium hypochloriteHydrogen peroxideLuminescenceChemiluminescenceTalanta
researchProduct

Theoretical prediction of the chemiluminescence behaviour of the ergot alkaloids

2004

Abstract The present manuscript is dealing with the application of molecular connectivity calculations to predict the chemiluminescent behaviour of ergot alkaloids when they react with common strong oxidants in liquid phase. Twenty compounds were theoretically studied by means of a discriminant equation formerly published, being 19 of them predicted as chemiluminescent with a high probability. Empirical confirmation of the chemiluminometric behaviour is performed with the few soluble and commercially available ergot alkaloids. On the basis of these results, a new FIA-direct chemiluminescent method is proposed for the determination of the ergot presenting the higher light emission, the pharm…

Detection limitChromatographyAlkaloidRepeatabilityTartrateBiochemistryAnalytical Chemistrylaw.inventionchemistry.chemical_compoundchemistryErgotamine TartratelawErgotaminemedicineEnvironmental ChemistryOrganic chemistryLight emissionSpectroscopyChemiluminescencemedicine.drugAnalytica Chimica Acta
researchProduct

Photochemical-chemiliminometric determination of aldicarb in a fully automated multicommutation based flow-assembly

2004

[EN] A sensitive and fully automated method for determination of aldicarb in technical formulations (Temik) and mineral waters is proposed. The automation of the flow-assembly is based on the multicommutation approach, which uses a set of solenoid valves acting as independent switchers. The operating cycle for obtaining a typical analytical transient signal can be easily programmed by means of a home-made software running in the Windows environment. The manifold is provided with a photoreactor consisting of a 150 cm long x 0.8 mm i.d. piece of PTFE tubing coiled around a 20 W low-pressure mercury lamp. The determination of aldicarb is performed on the basis of the iron(III) catalytic minera…

Detection limitChromatographyChemiluminescenceAldicarbAnalytical chemistryBiochemistryAnalytical Chemistrylaw.inventionMercury-vapor lampchemistry.chemical_compoundPotassium permanganatechemistryFully automatedlawMulticommutationTandem-flowPhotodegradationQUIMICA ANALITICAEnvironmental ChemistryPhotodegradationSpectroscopyTransient signalAldicarbChemiluminescence
researchProduct

Analytical strategy photodegradation/chemiluminescence/continuous-flow multicommutation methodology for the determination of the herbicide Propanil

2006

The present paper is dealing with an analytical strategy based on coupling photodegradation, chemiluminescence and multicommutation continuous-flow methodology for the determination of the pesticide Propanil, a common herbicide. The pesticide solution is inserted as small segments sequentially alternated with segments of the solution for adjusting the suitable medium for the photodegradation. Both flow-rates (sample and medium) are adjusted to required time for photodegradation, 2.0 min; and then, the resulting solution is also sequentially inserted as segments alternated with segments of the oxidizing solutions system, 1.00 x 10(-4) mol 1(-1) potassium permanganate in 2.00 mol 1(-1) sulphu…

Detection limitChromatographyChemiluminescenceCorrelation coefficientChemistryAlachlorAnalytical chemistryRepeatabilityAnalytical Chemistrylaw.inventionchemistry.chemical_compoundPotassium permanganatePhotoreactionlawMulticommutationPropanilQUIMICA ANALITICAPesticidesPhotodegradationChemiluminescence
researchProduct

Analysis of Chlorpyrifos in Water, Fruit Juice, and Honeybee Extract by Chemiluminescent Elisa

2008

Abstract The suitability of competitive enzyme-linked immunosorbent assays (ELISAs) with chemiluminescent detection-based immobilized antigen (indirect assay) for rapid and accurate determination of chlorpyrifos in various food matrices was tested. The limit of detection (LOD) values were 1–1.75 ng mL−1, the standard curve midpoint (IC50) was 3.5 ng mL−1, and the assay duration was 1.5 h. Assay application to the analysis of honeybee extract resulted in chlorpyrifos recoveries varying between 62 and 83% in 5–15 ng mL−1 herbicide concentration range.

Detection limitChromatographyChemistryBiochemistry (medical)Clinical BiochemistryFOOD/FRUIT JUICESBiochemistryCHEMILUMINESCENCECHLORPYRIFOSAnalytical Chemistrylaw.inventionStandard curveHONEYBEEchemistry.chemical_compoundlawChlorpyrifosElectrochemistryELISAFruit juiceIC50SpectroscopyChemiluminescenceAnalytical Letters
researchProduct

A chemiluminescence flow-based procedure for determination of carbaryl in natural waters exploiting multicommutation and enzymatic reaction

2007

A chemiluminescence procedure for the determination of carbaryl in natural waters using acetylcholinesterase and choline oxidase is described. The flow system designed to implement multicommutation approach controlled by microcomputer comprised five solenoid valves, two columns with immobilized enzymes on controlled pore glass beads and chemiluminometric flow cell. In the best experimental conditions a linear response ranging from 25 to 700 µg L-1 carbaryl was obtained. Water samples were spiked with carbaryl in order to access the accuracy and recoveries between 95 and 101% were obtained for a concentration level ranging from 25 to 100 µg L-1 carbaryl. Detection limit and variation coeffic…

Detection limitChromatographyImmobilized enzymeChemistryPotassiumchemistry.chemical_elementGeneral ChemistryCholine oxidasechemiluminescenceLuminollaw.inventionpesticide carbarylchemistry.chemical_compoundmulticommutationlawReagentCarbarylflow analysisChemiluminescenceenzymatic reaction
researchProduct