Search results for "maxilla"
showing 10 items of 450 documents
Binaural beats or 432 Hz music? which method is more effective for reducing preoperative dental anxiety?
2020
Background The aim of this prospective clinical study was to investigate the effectiveness of binaural beats and music at a frequency of 432 Hz and compare which method is more effective for reducing preoperative dental anxiety in impacted third molar surgery. Material and Methods Ninety patients were randomly selected to the binaural beats group, music group and control group. Visual analog scale used to evaluate dental anxiety before the local anesthesia in the first measurement. Local anesthesia was applied to the all patients. Patients in the music group listened to 432 Hz tuned music using earphones for 10 minutes. Patients in the binaural beats group listened to binaural beats using e…
Complications of guided surgery and immediate loading in oral implantology: a report of 12 cases.
2011
Objectives: The growing interest in minimally invasive surgery, together with the possibility of fitting prostheses with immediate function, have led to the development of software capable of planning and manufacturing a surgical guide and prosthesis that can be placed upon conclusion of the implant surgery step. The present study evaluates the surgical and prosthetic complications of implant treatment with the guided surgery technique, together with patient comfort during and after treatment. Patients and methods: A retrospective observational study was made of 19 patients with partially or totally edentulous upper and/or lower maxillae, involving the placement of a total of 122 implants. …
Analysis of marginal bone loss and implant stability quotient by resonance frequency analysis in different osteointegrated implant systems. Randomize…
2019
Background The aim of the present prospective clinical study is to compare the stability of the implant-bone interface by the ISQ quotient and marginal bone loss (MBL) rate during one year of follow-up in four system implants with the same surface and different design. Material and Methods Prospective randomized clinical trial of 21 patients in which four implant systems with the same surface and different design were placed. Patients were treated by the same operator following a similar surgical protocol with submerged technique. The second surgery to perform the prosthesis was performed at 3 months. All patients went to their review at 6 months and a year. A periapical radiograph for cres…
Zirconia Removable Telescopic Dentures Retained on Teeth or Implants for Maxilla Rehabilitation. Three-Year Observation of Three Cases
2010
Abstract This report addresses maxillary restoration with removable telescopic crown-retained palatal free dentures. One patient with 7 natural teeth (PERIO), a second patient with 6 dental implants (IMPL), and a third patient with 2 natural teeth and 4 dental implants (IMPL-PERIO) were treated. Zirconia copings for natural teeth and individual zirconia implant abutments were fabricated in CAD/CAM and used as primary crowns. Electroformed gold copings were used as secondary telescopes. All maxilla supraconstructions were fabricated with zirconia and CAD/CAM. Patients were monitored during a 3-year period; all teeth and implants survived, and no biological or mechanical complications occurre…
Effects of mandibular setback surgery on upper airway dimensions and their influence on obstructive sleep apnoea - a systematic review.
2015
Abstract Background Mandibular setback used to be the traditional treatment of choice for correcting mandibular prognathism. Nowadays, bimaxillary surgery is preferred. Several authors have asserted that mandibular setback causes a relative narrowing of the upper airway (UA) that could trigger obstructive sleep apnoea (OSA); however, its potential role in OSA development is still much debated. Another controversial subject is whether changes in airway space caused by the procedure are permanent. Objectives To ascertain the consequences for UA size and shape of mandibular setback surgery in comparison with bimaxillary surgery (maxillary advancement with Le Fort I and mandibular setback), and…
Effects of endodontic treatment on apparent Young’s modulus of human teeth: in vitro study using speckle interferometry
2012
The introduction of new techniques for endodontic procedures requires the analysis of the biomechanical behavior of dental structures. Digital speckle shearing pattern interferometry (DSSPI) is a nondestructive optical measuring technique that allows one to directly quantify deformations in teeth that are subjected to stress. DSSPI technique was applied to measure small deformations caused by flexion in different types of teeth. The test was carried out both before and after endodontic treatment with the ProTaper method in order to evaluate the variation of dental elasticity, taking into the account the type of tooth and the endodontic treatment. The results obtained show that dental elasti…
Inclusion of the periodontal ligament in studies on the biomechanical behavior of fiber post-retained restorations: An in vitro study and three-dimen…
2016
Endodontically treated teeth are known to have reduced structural strength. Periodontal ligament may influence fracture resistance. The purpose of this study was to assess the influence of including the periodontal ligament in biomechanical studies about endodontically treated and restored teeth. Forty human maxillary central incisors were treated endodontically and randomly divided into four groups: non-crowned (with and without an artificial ligament) and crowned (with and without an artificial ligament) with glass-ceramic crowns. All groups received prefabricated glass-fiber posts and a composite resin core. Specimens were tested, under a flexural–compressive load, until failure occurre…
Efficacy of three methods for inserting calcium hydroxide-based paste in root canals
2017
BACKGROUND: To compare the quality of calcium hydroxide paste fillings performed by three different techniques. MATERIAL AND METHODS: Sixty extracted maxillary central incisors, with previous root canal treatment, were decoronated and the gutta-percha was completely removed from the root canals. Subsequently, the canals were filled with a calcium hydroxide-based paste composed of calcium hydroxide, bismuth carbonate, and glycerin. The study samples were divided into the following three groups on the basis of three insertion techniques (n = 20, each): conventional technique using a hand instrument (MAN), rotary Lentulo spiral (LEN) technique, and a combined technique combining conventional h…
Roentgenographic in vitro investigation of frequency and location of curvatures in human maxillary premolars.
2006
The aim of this study was to determine the location of the root canal curvature and measure the distance from the CEJ to the first curvature using in vitro methods. Extracted maxillary premolars (n = 358) were fixed and digitally radiographed using the parallel technique. Excluded from further analysis were teeth with root caries, artificial crowns, extensive fillings, or endodontic treatments. The results were descriptively analyzed and the cumulative frequencies were calculated. The median values of the distance between CEJ and first curvature were for the first right premolars 8.4 mm (buccal) and 8.5 mm (palatal), for the first left premolars 9.1 mm (buccal) and 8.9 mm (palatal). The med…
A study on stress distribution to cement layer and root dentin for post and cores made of CAD/CAM materials with different elasticity modulus in the …
2019
Background To evaluate the stress distribution in a maxillary central incisor with different post and cores made of six CAD/CAM materials with different elastic modulus in the absence of ferrule using the finite element analysis. Material and methods A three-dimensional endodontically treated maxillary central incisor restored with an all-ceramic crown was modelled in Rhinoceros (5.0 SR8, McNeel). The geometries were analyzed in ANSYS 17.2 (ANSYS Inc.) considering isotropic, homogeneous, linearly elastic materials with perfectly bonded contacts. The elastic moduli (E) of the post-and-cores defined the groups to be compared: nanoceramic resin (E=12.8GPa); composite resin (E=16GPa); hybrid ce…