The AX-PET demonstrator—Design, construction and characterization

2011

Abstract Axial PET is a novel geometrical concept for Positron Emission Tomography (PET), based on layers of long scintillating crystals axially aligned with the bore axis. The axial coordinate is obtained from arrays of wavelength shifting (WLS) plastic strips placed orthogonally to the crystals. This article describes the design, construction and performance evaluation of a demonstrator set-up which consists of two identical detector modules, used in coincidence. Each module comprises 48 LYSO crystals of 100 mm length and 156 WLS strips. Crystals and strips are readout by Geiger-mode Avalanche Photo Diodes (G-APDs). The signals from the two modules are processed by fully analog front-end …

PhysicsNuclear and High Energy PhysicsPhysics::Instrumentation and Detectorsbusiness.industryPhysics::Medical PhysicsDetectorPhase (waves)STRIPSLyso-law.inventionSilicon photomultiplierData acquisitionOpticsCardinal pointpet; axial geometry; brain; scanner; sipm; detector; geiger-mode avalanche photo diodes (g-apd)lawbusinessInstrumentationDiodeNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Preliminary assessment of the imaging capability of the YAP–(S)PET small animal scanner in neuroscience

2006

The new and fully engineered version of the YAP–(S)PET small animal scanner has been tested at the University of Mainz for preliminary assessment of its imaging capability for studies related to neuropharmacology and psychiatry. The main feature of the scanner is the capability to combine PET and SPECT techniques. It allows the development of new and interesting protocols for the investigation of many biological phenomena, more effectively than with PET or SPECT modalities alone. The scanner is made up of four detector heads, each one composed of a 4 � 4c m 2 of YAlO3:Ce (or YAP:Ce) matrix, and has a field of view (FOV) of 4 cm axially � 4c m + transaxially. In PET mode, the volume resoluti…

PhysicsNuclear and High Energy PhysicsScannermedicine.medical_specialtymedicine.diagnostic_testDetectorCollimatorField of viewSingle-photon emission computed tomographylaw.inventionFeature (computer vision)lawPositron emission tomographySmall animalmedicineMedical physicsInstrumentationBiomedical engineeringNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

First feasibility study for EXL prototype detectors at the ESR and detector simulations

2009

This contribution presents some results from the first feasibility measurement performed at GSI using a 350 MeV/nucleon 136 Xe beam and a Hydrogen gas-jet target. In this feasibility study, one element of every possible detection part of the future EXL detection system was investigated. In addition, simulation results for EXL setup will be presented.

PhysicsNuclear and High Energy Physicsmedicine.medical_specialtyNuclear engineeringDetectormedicineGeneral Physics and AstronomyMedical physicsBeam (structure)International journal of modern physics e-Nuclear physics
researchProduct

Detector blockbased on arrays of 144 SiPMs and monolithic scintillators: A performane study

2015

[EN] We have developed a detector block composed by a monolithic LYSO scintillator coupled to a custom made 12 12 SiPMs array. The design is mainly focused to applications such as Positron Emission Tomography. The readout electronics is based on 3 identical and scalable Application Specific Integrated Circuits (ASIC). We have determined the main performance of the detector block namely spatial, energy, and time resolution but also the system capability to determine the photon depth of interaction, for different crystal surface treatments. Intrinsic detector spatial resolution values as good as 1.7 mm FWHM and energies of 15% for black painted crystals were measured. & 2014 Elsevier B.V. All…

PhysicsNuclear and High Energy Physicsmedicine.medical_specialtyPhotonPhysics::Instrumentation and Detectorsbusiness.industryASICDetectorSilicon photomultipliersScintillatorScintillator crystalFull width at half maximumSilicon photomultiplierApplication-specific integrated circuitmedicineOptoelectronicsMedical physicsbusinessMATEMATICA APLICADAInstrumentationImage resolutionPositron Emission TomographyBlock (data storage)
researchProduct

Development of silicon pad detectors and readout electronics for a Compton camera

2003

Abstract Applications in nuclear medicine and bio-medical engineering may profit using a Compton camera for imaging distributions of radio-isotope labelled tracers in organs and tissues. These applications require detection of photons using thick position-sensitive silicon sensors with the highest possible energy and good spatial resolution. In this paper, research and development on silicon pad sensors and associated readout electronics for a Compton camera are presented. First results with low-noise, self-triggering VATAGP ASIC's are reported. The measured energy resolution was 1.1 keV FWHM at room temperature for the 241 Am photo-peak at 59.5 keV .

PhysicsNuclear and High Energy Physicsmedicine.medical_specialtyPhotonSiliconPhysics::Instrumentation and Detectorsbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaDetectorCompton scatteringchemistry.chemical_elementParticle detectorSemiconductor detectorOpticschemistryMeasuring instrumentmedicineMedical physicsbusinessInstrumentationImage resolutionNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Estimating accidental coincidences for pixelated PET detectors and singles list-mode acquisition

2007

We have studied the validity of random estimation techniques for various low energy thresholds (LETs) and single list-mode data sets in small animal PET. While a LET below 255 keV helps to increase the sensitivity, it also results in an increase of random coincidences and inter-crystal scatter (ICS). The study is carried out for MADPET-II, a dual-layer positron emission tomography (PET) scanner prototype consisting of LSO crystals read out individually by APDs. The data are acquired in singles list-mode format, and coincidences are computed post-acquisition. To estimate randoms, we have used the delayed coincidence window method (DW), and the singles rate model (SR). Various phantoms were s…

PhysicsNuclear and High Energy Physicsmedicine.medical_specialtyScannerAPDSmedicine.diagnostic_testDetectorCoincidenceParticle detectorComputational physicslaw.inventionMockuplawmedicineMedical physicsInstrumentationRandomnessEmission computed tomographyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

A prototype of very high resolution small animal PET scanner using silicon pad detectors

2007

Abstract A very high-resolution small animal positron emission tomograph (PET), which can achieve sub-millimeter spatial resolution, is being developed using silicon pad detectors. The prototype PET for a single slice instrument consists of two 1 mm thick silicon pad detectors, each containing a 32×16 array of 1.4×1.4 mm pads readout with four VATAGP3 chips which have 128 channels low-noise self-triggering ASIC in each chip, coincidence units, a source turntable and tungsten slice collimator. The silicon detectors were located edgewise on opposite sides of a 4 cm field-of-view to maximize efficiency. Energy resolution is dominated by electronic noise, which is 0.98% (1.38 keV) FWHM at 140.5…

PhysicsNuclear and High Energy Physicsmedicine.medical_specialtySiliconbusiness.industryDetectorResolution (electron density)chemistry.chemical_elementCollimatorChipLine sourceArticlelaw.inventionOpticschemistrylawmedicineWaferMedical physicsbusinessInstrumentationImage resolution
researchProduct

Monte Carlo evaluation of the Filtered Back Projection method for image reconstruction in proton computed tomography

2011

Abstract In this paper the use of the Filtered Back Projection (FBP) Algorithm, in order to reconstruct tomographic images using the high energy (200–250 MeV) proton beams, is investigated. The algorithm has been studied in detail with a Monte Carlo approach and image quality has been analysed and compared with the total absorbed dose. A proton Computed Tomography (pCT) apparatus, developed by our group, has been fully simulated to exploit the power of the Geant4 Monte Carlo toolkit. From the simulation of the apparatus, a set of tomographic images of a test phantom has been reconstructed using the FBP at different absorbed dose values. The images have been evaluated in terms of homogeneity…

PhysicsNuclear and High Energy Physicsmedicine.medical_specialtyTomographic reconstructionRadon transformImage qualitybusiness.industryPhysics::Medical PhysicsMonte Carlo methodIterative reconstructionImaging phantomOpticsAbsorbed doseHomogeneity (physics)medicineMedical physicsbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Gyrotron-driven high current ECR ion source for boron-neutron capture therapy neutron generator

2014

Abstract Boron-neutron capture therapy (BNCT) is a perspective treatment method for radiation resistant tumors. Unfortunately its development is strongly held back by a several physical and medical problems. Neutron sources for BNCT currently are limited to nuclear reactors and accelerators. For wide spread of BNCT investigations more compact and cheap neutron source would be much more preferable. In present paper an approach for compact D–D neutron generator creation based on a high current ECR ion source is suggested. Results on dense proton beams production are presented. A possibility of ion beams formation with current density up to 600 mA/cm 2 is demonstrated. Estimations based on obt…

PhysicsNuclear and High Energy Physicsta114Nuclear engineeringPhysics::Medical PhysicsNuclear TheoryRadiationIon sourcelaw.inventionNeutron captureNeutron generatorNeutron fluxlawGyrotronNeutron sourceNeutronNuclear ExperimentInstrumentationta217Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Monte Carlo and experimental derivation of TG43 dosimetric parameters for CSM-type Cs-137 sources

2004

In this study, complete dosimetric datasets for the CSM2 and CSM3 Cs-137 sources were obtained using the Monte Carlo GEANT4 code. The application of this calculation method was experimentally validated with thermoluminescent dosimetry (TLD). Functions and parameters following the TG43 formalism are presented: the dose rate constant, the radial dose functional, and the anisotropy function. In addition, to aid the quality control process on treatment planning systems, a two-dimensional (2D) rectangular dose rate table (the traditional along-away table), coherent with the TG43 dose calculation formalism, is given. The data given in this study complement existing information for both sources on…

PhysicsPhotonmedia_common.quotation_subjectPhysics::Medical PhysicsMonte Carlo methodGeneral MedicineAsymmetryThermoluminescent DosimetryDosimetryStatistical physicsThermoluminescent dosimeterAnisotropyImage resolutionmedia_commonMedical Physics
researchProduct