Search results for "medical physics"
showing 10 items of 579 documents
EP-1590: Shielding design and fetal dose evaluation of a breast cancer pregnant patient undergoing HDR Ir-192 brachytherapy
2015
Magnetic resonance image segmentation and heart motion tracking with an active mesh based system
2002
International audience; Abstract: The work presented here relates to a method fir motion tracking in sequences of medical images. The purpose is to. quantify the general motions and the local deformations of a beating heart during a cardiac cycle. In order to achieve this goal, we first tessellate the,first image of the sequence into triangular patches. A Delaunay triangulation is applied to find the optimal set of triangles describing this image, giving a mesh covering the organs. One imposes the contours of the organs to correspond to edges of triangles so that each part of the heart (left ventricle, right ventricle, myocardium) can he described as a different set of triai izles, each set…
GPCALMA: A Grid-based tool for mammographic screening
2005
The next generation of High Energy Physics (HEP) experiments requires a GRID approach to a distributed computing system and the associated data management: the key concept is the Virtual Organisation (VO), a group of distributed users with a common goal and the will to share their resources. A similar approach is being applied to a group of Hospitals which joined the GPCALMA project (Grid Platform for Computer Assisted Library for MAmmography), which will allow common screening programs for early diagnosis of breast and, in the future, lung cancer. HEP techniques come into play in writing the application code, which makes use of neural networks for the image analysis and proved to be useful…
Computer assisted diagnosis (CAD) in mammography. Comparison of diagnostic accuracy of a new algorithm (Cyclopus(R), Medicad) with two commercial sys…
2008
The study compares the diagnostic accuracy (correct identification of cancer) of a new computer-assisted diagnosis (CAD) system (Cyclopus) with two other commercial systems (R2 and CADx). Cyclopus was tested on a set of 120 mammograms on which the two compared commercial systems had been previously tested. The set consisted of mammograms reported as negative, preceding 31 interval cancers reviewed as screening error or minimal sign, and of 89 verified negative controls randomly selected from the same screening database. Cyclopus sensitivity was 74.1% (R2=54.8%; CADx=41.9%) and was higher for interval cancers reviewed as screening error (90.9%; R2=54.5%; CADx=81.8%) compared with those revie…
Correction factors for ionization chamber measurements with the ‘Valencia’ and ‘large field Valencia’ brachytherapy applicators
2018
Treatment of small skin lesions using HDR brachytherapy applicators is a widely used technique. The shielded applicators currently available in clinical practice are based on a tungsten-alloy cup that collimates the source-emitted radiation into a small region, hence protecting nearby tissues. The goal of this manuscript is to evaluate the correction factors required for dose measurements with a plane-parallel ionization chamber typically used in clinical brachytherapy for the 'Valencia' and 'large field Valencia' shielded applicators. Monte Carlo simulations have been performed using the PENELOPE-2014 system to determine the absorbed dose deposited in a water phantom and in the chamber act…
Solar Surface Magnetism and Irradiance on Time Scales from Days to the 11-Year Cycle
2009
The uninterrupted measurement of the total solar irradiance during the last three solar cycles and an increasing amount of solar spectral irradiance measurements as well as solar imaging observations (magnetograms and photometric data) have stimulated the development of models attributing irradiance variations to solar surface magnetism. Here we review the current status of solar irradiance measurements and modelling efforts based on solar photospheric magnetic fields. Thereby we restrict ourselves to the study of solar variations from days to the solar cycle. Phenomenological models of the solar atmosphere in combination with imaging observations of solar electromagnetic radiation and meas…
Iron oxides nanoparticles and titanate nanotubes dedicated to multimodal imaging and anticancer therapy
2013
The new implementations of nanoparticles in the medical field are one of the essential factors of the medical progress expected at the beginning of this XXIst century. Thus, the domain of the medical imaging is also affected by this technological evolution. This work consisted in developing theranostic probes with iron oxides nanoparticles (SPIO) and titanate nanotubes (TiONts) for multimodal imaging (magnetic/nuclear or magnetic/optical) and also possessing a therapeutic effect (hyperthermia/PDT or radiosensitization/PDT).The titanate nanotubes of this study have an average length of about 150 nm and were obtained by Kasuga's hydrothermal synthesis. These nanotubes present an outside diame…
Distribution of oxygen partial pressure in a two-dimensional tissue supplied by capillary meshes and concurrent and countercurrent systems
1969
Abstract For the calculations of oxygen partial pressure in a two-dimensional tissue model supplied by a capillary network (inhomogeneously perfused tissue), two differential equations are given that describe the process in the tissue and capillaries. The differential equations are coupled by the boundary conditions. Results obtained by using the method of successive displacements are given for the two-dimensional problem. This method exhibits a satisfactory convergence. The accuracy of the results is about ±5% based on the initial concentration. The results for the network model are compared with those for equivalent concurrent and countercurrent systems. Equivalence means in this connecti…
Exploring the Potential of Short-Baseline Physics at Fermilab
2018
We study the capabilities of the short baseline neutrino program at Fermilab to probe the unitarity of the lepton mixing matrix. We find the sensitivity to be slightly better than the current one. Motivated by the future DUNE experiment, we have also analyzed the potential of an extra liquid Argon near detector in the LBNF beamline. Adding such a near detector to the DUNE setup will substantially improve the current sensitivity on non-unitarity. This would help to remove CP degeneracies due to the new complex phase present in the neutrino mixing matrix. We also study the sensitivity of our proposed setup to light sterile neutrinos for various configurations.
Refractive analysis of the human cornea through propagated fields
2001
A new technique for analysing the optical quality of the human cornea is presented. Corneal maps are obtained through keratographies and then converted into phase maps. The propagated fields generated from this surface are plotted and studied. It is shown that any irregularity in the cornea affects the propagated field and the energy distribution at the focal plane. Simple applications are also indicated.