Search results for "mesopic vision"

showing 10 items of 45 documents

Visual quality after diffractive intraocular lens implantation in eyes with previous hyperopic laser in situ keratomileusis

2010

To evaluate distance, intermediate, and near visual quality in eyes with diffractive intraocular lens (IOL) implantation after previous hyperopic laser in situ keratomileusis (LASIK).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Cohort study.Corrected distance visual acuity (CDVA) at 12.5%, 25.0%, and 100% contrast levels under photopic and mesopic conditions; uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity, defocus curves, and corneal higher-order aberrations (HOAs) were measured in eyes that had AcrySof Restor SN60D3 spherical IOL implantation (study group) and in phakic eyes (control group) after hyperopic LASIK.Under photopic conditions at 100% contrast, …

Malemedicine.medical_specialtyRefractive errorVisual acuitygenetic structuresMesopic visionmedicine.medical_treatmentKeratomileusis Laser In SituMesopic VisionVisual AcuityIntraocular lensKeratomileusisRefraction OcularCohort StudiesLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesAgedPostoperative CarePhacoemulsificationColor Visionbusiness.industryLASIKPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyHyperopiaOptometryFemaleLasers ExcimerSurgerysense organsmedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Visual Acuity and Contrast Sensitivity in Eyes Implanted with Aspheric and Spherical Intraocular Lenses

2009

Purpose To compare visual acuity and contrast sensitivity (CS) in eyes implanted with aspheric and spherical intraocular lenses (IOLs) after cataract surgery. Design Randomized, prospective study. Participants Five hundred twenty-four eyes from 262 cataract surgery patients implanted with 2 IOL models: the AcrySof IQ (262 eyes) and AcrySof SN60AT (262 eyes; Alcon Laboratories, Fort Worth, TX). Methods High-contrast photopic best-corrected distance visual acuity (BCVA) and CS under photopic (85 cd/m 2 ) and mesopic (6 cd/m 2 ) conditions were measured. Pupil diameter was analyzed for distance vision under both lighting conditions. Follow-up was carried out for 6 months in all patients. Main …

Malemedicine.medical_specialtyVisual acuityLightPseudophakiagenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentAcrylic ResinsVisual AcuityDark AdaptationIntraocular lensCataract ExtractionProsthesis DesignContrast SensitivityLens Implantation IntraocularVision MonocularOphthalmologymedicineHumansContrast (vision)Prospective StudiesAgedmedia_commonLenses Intraocularbusiness.industryPupilCataract surgeryeye diseasesOphthalmologyAlcon LaboratoriesIntraocular lensesOptometryFemalesense organsmedicine.symptombusinessPhotopic visionOphthalmology
researchProduct

Visual Comparison of an Artificial Pupil Contact Lens to Monovision

2012

PURPOSE To assess and compare the effects of contact-lens based artificial pupil design and monovision correction on visual performance. METHODS In a cross-over study design, 22 presbyopic patients (age range 50 to 64 years) were evaluated using artificial pupil contact lens on the non-dominant eye and monovision. After 1 month, binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance contrast sensitivity, binocular near contrast sensitivity, and stereoacuity were measured, under photopic conditions (85 cd/m2), in each patient after contact lens fitting. Moreover, BDVA and binocular distance contrast sensitivity were examined under meso…

Malemedicine.medical_specialtyVisual acuitygenetic structuresContact LensesMesopic visionmedia_common.quotation_subjectVisual AcuityPupilVision MonocularOphthalmologymedicineHumansContrast (vision)media_commonMathematicsCross-Over StudiesPupilEquipment DesignPresbyopiaMiddle Agedeye diseasesContact lensStereoscopic acuityOphthalmologyTreatment OutcomeFemaleSpatial frequencymedicine.symptomFollow-Up StudiesOptometryPhotopic visionOptometry and Vision Science
researchProduct

Visual Performance of a Multifocal Toric Soft Contact Lens

2012

PURPOSE To evaluate the visual performance of the Proclear multifocal toric contact lens (CL; CooperVision, US) for both presbyopia and astigmatism correction. METHODS In this crossover study design, 20 presbyopic subjects with astigmatism were fitted in a random order with either Proclear multifocal toric CL or Proclear toric single vision distance CL (DCL) combined with reading spectacles. After 1 month, high-contrast distance visual acuity, near high-contrast visual acuity, distance contrast sensitivity (CS) under photopic and mesopic conditions without and with glare, near CS, defocus curve, and stereopsis were measured. Subjects were then refitted with the alternative correction, and t…

Malemedicine.medical_specialtyVisual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectVisual AcuityAstigmatismRefraction OcularOphthalmologymedicineHumansContrast (vision)AgedMathematicsmedia_commonCross-Over StudiesGlare (vision)Equipment DesignPresbyopiaMiddle AgedContact Lenses HydrophilicRefractive Errorsmedicine.diseaseeye diseasesContact lensOphthalmologyFemalemedicine.symptomOptometryPhotopic visionOptometry and Vision Science
researchProduct

Visual function after implantation of an aspheric bifocal intraocular lens.

2009

Purpose To evaluate distance, intermediate, and near vision after bifocal aspheric AcrySof ReSTOR SN6AD1 intraocular lens (IOL) implantation. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Methods Binocular distance best corrected visual acuity (BCVA) (4.0 m), best distance-corrected near (40.0 cm) and intermediate (70.0, 60.0, 50.0 cm) acuities, and contrast sensitivity under photopic (85.0 candelas [cd]/m 2 ) and mesopic (3.0 cd/m 2 ) conditions with and without glare were measured postoperatively. A patient-satisfaction and visual phenomena questionnaire was administered. Results Six months postoperatively, the mean acuities (logMAR) were binocular BCVA, −0.064 ± 0.049…

Malemedicine.medical_specialtygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentVisual AcuityIntraocular lensProsthesis DesignContrast SensitivityLens Implantation IntraocularOphthalmologySurveys and QuestionnairesMedicineContrast (vision)HumansProspective StudiesDioptremedia_commonAgedLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryGlare (vision)Middle Agedeye diseasesSensory SystemsOphthalmologyPatient SatisfactionVisual DisturbanceOptometrySurgeryFemaleSpatial frequencybusinessPhotopic visionJournal of cataract and refractive surgery
researchProduct

Visual function after bilateral implantation of a new zonal refractive aspheric multifocal intraocular lens.

2011

Purpose To evaluate visual function after bilateral implantation of a zonal refractive aspheric multifocal intraocular lens (IOL). Setting Private practice surgery center, Valencia, Spain. Design Cohort study. Methods Consecutive eyes with cataract had bilateral implantation of Lentis Mplus LS-312 multifocal IOLs. Distance, intermediate, and near visual acuities; contrast sensitivity; defocus curves; and a quality-of-vision questionnaire, including presence of halos or dysphotopsia, were evaluated 6 months postoperatively. A control group of age-matched monofocal pseudophakic patients was included to compare contrast sensitivity function. Results In the multifocal group, the mean binocular …

Malemedicine.medical_specialtygenetic structuresPseudophakiaMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentVision DisordersVisual AcuityIntraocular lensProsthesis DesignCohort StudiesContrast SensitivityLens Implantation IntraocularOphthalmologySurveys and QuestionnairesmedicineContrast (vision)HumansProspective Studiesmedia_commonAgedLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryGlare (vision)PhacoemulsificationMultifocal intraocular lensMiddle Agedeye diseasesSensory SystemsOphthalmologyPrivate practiceQuality of LifeOptometrySurgeryFemalesense organsbusinessPhotopic visionJournal of cataract and refractive surgery
researchProduct

Mesopic vision characteristics at decreased contrast in fog

2010

Perception of different color contrast stimuli was studied in the presence of light scattering in a fog chamber in Clermont-Ferrand and in laboratory conditions where light scattering of similar levels was obtained. Blue (shortest wavelength) light is scattered in fog to the greatest extent, causing deterioration of vision quality especially for the monochromatic blue stimuli. We have done spectral measurements of the light source in different density fog conditions and no spectral changes were found produced by the fog. Psychophysical measurements of the acuity in fog were done for two subjects with optotypes analyzed for red and blue stimuli.

Materials sciencegenetic structuresbusiness.industryMesopic visionmedia_common.quotation_subjectLight scatteringWavelengthOpticsLight sourceContrast (vision)Monochromatic colorColor contrastbusinessVisibilitymedia_commonSPIE Proceedings
researchProduct

Correlation between optics quality of multifocal intraocular lenses and visual acuity

2009

Purpose To study the relationship between the optics quality of multifocal intraocular lenses (IOLs) and distance-corrected near, intermediate, and distance visual acuity to determine the degree to which optics quality must change to produce a significant difference in visual acuity. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods Monocular distance-corrected visual acuity (decimal and logMAR) was measured at 4 m, 70 cm, and 30 cm under photopic and mesopic conditions in eyes with 1 of 3 multifocal IOL models. Visual acuity versus the “average modulation” of the IOL was assessed. Results The pupil diameter and patient age were similar between the 3 IOL groups (20 …

Optics and Photonicsmedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresMesopic visionColor visionmedicine.medical_treatmentVisual AcuityIntraocular lensPupilOpticsLens Implantation IntraocularOphthalmologymedicineHumansAgedRetrospective StudiesLenses IntraocularPhacoemulsificationColor VisionFourier Analysisbusiness.industryPupilPhacoemulsificationMultifocal intraocular lenseye diseasesSensory SystemsOphthalmologyOptometrySurgerysense organsmedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Dopamine antagonists impair ‘red-green’ discrimination in goldfish after intravitreal injection

1995

Color vision in goldfish is tetrachromatic. However, under mesopic illumination conditions the L-cones do not contribute to wavelength discrimination, and color vision becomes trichromatic. To investigate the role of dopamine in light adaptation, we tested the effect of the unspecific dopamine antagonist haloperidol and of the specific dopamine Dl receptor antagonists SCH 23390 and SKF 83566-biotinyl in behavioral wavelength discrimination experiments. After injection of dopamine antagonists into the vitreous, a reduction in wavelength discrimination was observed in the range between 560 nm and 630 nm but not in the range between 404 nm and 501 nm.

SCH-23390genetic structuresChemistryMesopic visionColor visionStereochemistryTrichromacyDopamine antagonistchemistry.chemical_compoundDopaminemedicineHaloperidolBiophysicssense organsReceptormedicine.drug
researchProduct

Analysis of the possible benefits of aspheric intraocular lenses: review of the literature.

2008

We reviewed recently published studies that analyzed the visual and optical quality in eyes with different spherical and aspheric intraocular lenses (IOLs). Recent studies focused on visual quality metrics, such as visual acuity and contrast sensitivity, under photopic and mesopic lighting conditions and optical metrics, such as wavefront aberrations, especially spherical aberration. The results in this review were used in an attempt to understand whether there is a visual and/or optical benefit of implanting aspheric IOLs over implanting spherical IOLs.

Visual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentVisual AcuityIntraocular lensProsthesis DesignContrast SensitivityOpticsLens Implantation IntraocularMedicineContrast (vision)Humansmedia_commonWavefrontLenses Intraocularbusiness.industryeye diseasesSensory SystemsOphthalmologySpherical aberrationIntraocular lensesOptometrySurgerysense organsmedicine.symptombusinessPhotopic visionJournal of cataract and refractive surgery
researchProduct