Search results for "methods"
showing 10 items of 4526 documents
Exploratory multiblock data: do they lead to the same results?
2022
Probability and algorithmics: a focus on some recent developments
2017
Jean-François Coeurjolly, Adeline Leclercq-Samson Eds.; International audience; This article presents different recent theoretical results illustrating the interactions between probability and algorithmics. These contributions deal with various topics: cellular automata and calculability, variable length Markov chains and persistent random walks, perfect sampling via coupling from the past. All of them involve discrete dynamics on complex random structures.; Cet article présente différents résultats récents de nature théorique illustrant les interactions entre probabilités et algorithmique. Ces contributions traitent de sujets variés : automates cellulaires et calculabilité, chaînes de Mark…
Approche préventive de la qualité des données d'importation dans le contexte de la protéomique clinique
2011
International audience; Dans le domaine biomédical, la protéomique est confrontée à des sources de données de plus en plus nombreuses et à des volumes de données très importants du fait de la multiplication des technologies dites à haut débit. L'hétérogénéité de la provenance des données implique de fait une hétérogénéité dans la représentation et le contenu de ces données. Les données peuvent aussi se révéler incorrectes ce qui engendre des erreurs sur les conclusions des expériences protéomiques. Notre approche a pour objectif de garantir la qualité initiale des données lors de leur importation dans un système d'information dédié à la protéomique. Elle est basée sur le couplage entre des …
Results from the ULTRA experiment in the framework of the EUSO project
2005
The detection of Cerenkov light from EAS in a delayed coincidence with fluorescence light gives a strong signature to discriminate protons and neutrinos in cosmic rays. For this purpose, the ULTRA experiment has been designed with 2 detectors: a small EAS array (ETscope) and an UV optical device including wide field (Belenos) and narrow field (UVscope) Cerenkov light detectors. The array measures the shower size and the arrival direction of the incoming EAS, while the UV devices, pointing both to zenith and nadir, are used to determine the amount of direct and diffused coincident Cerenkov light. This information, provided for different diffusing surfaces, will be used to verify the possibil…
Requirements and simulation study of the performance of EUSO as external payload on board the international space station
2005
The "Extreme Universe Space Observatory - EUSO" has been conceived as the first Space mission devoted to the investigation of Ultra High Energy Cosmic Ray, using the Earth's atmosphere as a giant detector. The scientific objectives of the experiment are to observe the UHECR spectrum above the GZK energy, with an improvement of one order of magnitude in the statistics of collected events with respect to the existing experiments, in such a way to study the source distribution in a full sky survey, as well as to open the channel (set a confidence limit) on the neutrino astronomy in this energy range. Supposed to be accommodated as external payload on board the International Space Station, EUSO…
Constraints on the origin of cosmic rays above 10^18 eV from large-scale anisotropy searches in data of the Pierre Auger Observatory
2012
A thorough search for large-scale anisotropies in the distribution of arrival directions of cosmic rays detected above 10(18) eV at the Pierre Auger Observatory is reported. For the first time, these large-scale anisotropy searches are performed as a function of both the right ascension and the declination and expressed in terms of dipole and quadrupole moments. Within the systematic uncertainties, no significant deviation from isotropy is revealed. Upper limits on dipole and quadrupole amplitudes are derived under the hypothesis that any cosmic ray anisotropy is dominated by such moments in this energy range. These upper limits provide constraints on the production of cosmic rays above 10(…
The rapid atmospheric monitoring system of the Pierre Auger Observatory
2012
The Pierre Auger Observatory is a facility built to detect air showers produced by cosmic rays above 1017 eV. During clear nights with a low illuminated moon fraction, the UV fluorescence light produced by air showers is recorded by optical telescopes at the Observatory. To correct the observations for variations in atmospheric conditions, atmospheric monitoring is performed at regular intervals ranging from several minutes (for cloud identification) to several hours (for aerosol conditions) to several days (for vertical profiles of temperature, pressure, and humidity). In 2009, the monitoring program was upgraded to allow for additional targeted measurements of atmospheric conditions shor…
Interpretation of the depths of maximum of extensive air showers measured by the Pierre Auger Observatory
2013
To interpret the mean depth of cosmic ray air shower maximum and its dispersion, we parametrize those two observables as functions of the first two moments of the ln A distribution. We examine the goodness of this simple method through simulations of test mass distributions. The application of the parameterization to Pierre Auger Observatory data allows one to study the energy dependence of the mean ln A and of its variance under the assumption of selected hadronic interaction models. We discuss possible implications of these dependences in term of interaction models and astrophysical cosmic ray sources.
Muons in air showers at the Pierre Auger Observatory
2015
We present the first hybrid measurement of the average muon number in air showers at ultrahigh energies, initiated by cosmic rays with zenith angles between 62° and 80°. The measurement is based on 174 hybrid events recorded simultaneously with the surface detector array and the fluorescence detector of the Pierre Auger Observatory. The muon number for each shower is derived by scaling a simulated reference profile of the lateral muon density distribution at the ground until it fits the data. A 1019eV shower with a zenith angle of 67°, which arrives at the surface detector array at an altitude of 1450 m above sea level, contains on average (2.68±0.04±0.48(sys))×107 muons with energies large…
Extending the search for neutrino point sources with iceCube above the horizon
2009
Point source searches with the IceCube neutrino telescope have been restricted to one hemisphere, due to the exclusive selection of upward going events as a way of rejecting the atmospheric muon background. We show that the region above the horizon can be included by suppressing the background through energy-sensitive cuts. This approach improves the sensitivity above PeV energies, previously not accessible for declinations of more than a few degrees below the horizon due to the absorption of neutrinos in Earth. We present results based on data collected with 22 strings of IceCube, extending its field of view and energy reach for point source searches. No significant excess above the atmosp…