Electric Power Quality Evaluation in the Presence of Electromagnetic Emissions
2013
The measurements for the assessment of the electric power quality are often carried out in hostile electromagnetic environments. The aim of the paper is analyzing if and how both radiated and conducted electromagnetic emissions can disturb the measurement system used to quantify these disturbances. To achieve the target, an experimental approach is proposed, which, by means of a simple and fast test, allows establishing if the real electromagnetic environment, where power quality analysis is performed, can alter the measurements. © 2013 IEEE.
Experimental EMF characterization of a secondary substation
2015
This paper presents the results of the experimental EMC characterization of a new medium/low voltage (MV/LV) secondary substation, which was developed in the framework of the research project "NEW CAB ELARC". It has two MV/LV transformers, with total rated power of 1000 kVA. To perform the experimental characterization, firstly an analysis was performed of the Italian and European standards recommendations. Different approaches were highlighted and the most appropriate procedures were identified for the measurement of the magnetic fields emissions, at power systems frequency (50 Hz) in steady-state conditions. A dedicated test lab was set up for the secondary substation characterization. Th…
PVDF based vibration measurements and their correlation with torque estimation in a FOC induction motor drive
2008
This paper presents a study concerning the vibrations generated by an induction motor drive controlled by field oriented control algorithm (FOC). The aim of the study is to identify suitable measurement points and analysis techniques in order to achieve information about vibration generated by an electric drive. Vibrations take origin both by the torque generated by the motor and the motor supply through an inverter, then they are transmitted to neighbouring structures. Torque is estimated on the basis of the estimated flux linkage; vibrations have been both measured and analysed numerically by FEM at two points of the cradle. The numerical and experimental analysis have been carried out fo…
A PC-based wattmeter for high accuracy power measurements
2010
This paper proposes the use of a commercial data acquisition board (DAQ) connected to a common personal computer for high accuracy power measurements. In the paper the set up of the PC-based wattmeter is described and an experimental evaluation of its metrological performances is made by means of the comparison with a simultaneous coherent digital sampling wattmeter realized with two high-precision DMMs Hewlett Packard Model 3458 A. In both cases the power source is a Fluke 6100A/E electrical power standard. © 2010 IEEE.
A novel approach to current transformer characterization in the presence of harmonic distortion
2009
The current transformer (CT) performance under distorted waveform conditions is usually characterized by means of the frequency-response test. In this paper, a new way to characterize CTs, closer to real operation conditions, is proposed. The harmonic phase-angle and ratio errors are measured using a nonsinusoidal current composed of fundamental and one harmonic with adjustable phase shift. The new method was tested by determining the performance of two metering class CTs commonly used by the Italian power company. The errors measured using the proposed approach are larger than the ones obtained with the frequency response. This result suggests that the frequency-response approach for the e…
Oil filled MV/LV Power Transformer Behavior in Narrow Band Power Line Communication Systems
2012
The aim of this paper is to characterize oil-filled power transformers in the narrow-band power-line communication (PLC) frequency range of 50-150 kHz. A new model is proposed for such type of a transformer, in the aforementioned frequency range of interest, in order to study its influence on the signal transmission and to investigate the possibility that the PLC signal can cross the power transformer itself. The new model is simpler than those previously proposed in literature, and it can be used in the whole frequency range available for NB PLC according to the CENELEC EN 50065-1 A-band. In order to validate the model, simulation and measurement results are compared for four oil-filled po…
An Innovative Measurement Approach for Load Flow Analysis in MV Smart Grids
2016
This paper proposes a novel measurement procedure for load flow analysis in medium voltage (MV) smart grids. The new approach is based on power measurements at low voltage (LV) side of MV/LV distribution substations. Such measurements are carried out by means of power quality analyzers. If compared with the load flow methods based on measurements at the MV side, the proposed approach has a lower cost and it offers an equally reliable measurement system. The proposed algorithm takes the basic concept of the current summation backward/forward method; some modifications are introduced to use LV load powers measurements. To this aim, the MV/LV power transformer is properly modeled and taken int…
A New Low Cost Coupling System for Power Line Communication on Medium Voltage Smart Grids
2018
This paper proposes and verifies the performance of an innovative and low cost coupling system for power line communication (PLC) on medium voltage (MV) smart grids. The coupling system makes use of the capacitive divider of the voltage detecting systems (VDSs) to inject and receive the PLC signal. VDS are usually already installed in the MV switchboards of the major electrical manufacturer all over the world according to IEC 61243-5. VDS are used to detect the presence of the mains voltage to guarantee personnel safety. An interface circuit has been developed to be connected between the PLC transceiver and the VDS socket. In this way, the PLC signal can be coupled to the MV network without…
Synchronization techniques for power quality instruments
2004
The measurement of voltage characteristics in power systems requires the accurate estimation of the power supply frequency and signal synchronization, even in the presence of disturbances. The authors developed and tested two innovative techniques for instrument synchronization. The first is based on signal spectral analysis techniques performed by means of the Chirp-Z transform analysis. The second is a phase-locked loop (PLL) software based on a time-domain coordinate transformation and an innovative phase-detection technique. To evaluate how synchronization techniques are adversely affected by the application of a disturbing influence, experimental tests were carried out, taking into acc…
New Measurement Procedure for Load Flow Evaluation in Medium Voltage Smart Grids
2013
The aim of this paper is to present a new approach for the medium voltage (MV) distribution network load flow analysis, mainly based on power measurement at the low voltage (LV) level of MV/LV distribution substations. This allows to use measurement instruments, usually already installed in the secondary substations, thus achieving an equally reliable measurement system with a lower cost compared to measurements at the MV side. The new approach can be applied using a proper communication system to collect the nodal measurements and an iterative algorithm based on ladder iterative technique (LIT) to compute the load flow. The validity of this method is presented and discussed on the basis of…