Search results for "monitor"

showing 10 items of 3841 documents

Exposure to nitroaromatic explosives and health effects during disposal of military waste.

2003

To investigate the exposure to dinitrotoluene (DNT) and trinitrotoluene (TNT) and the resulting effects in workers which occur during the disposal of military waste.Eighty two employees from a mechanical plant in Germany were studied, of whom 51 were regularly exposed to ammunition containing TNT and DNT, 19 occasionally, and 12 not at all.Air analyses yielded maximum concentrations of 20 micro g/m(3) for 2,4-DNT and 3250 micro g/m(3) for 2,4,6-TNT, respectively. The maximum concentrations in the urine of workers regularly exposed amounted to 5.0 micro g/l of 2,4,6-TNT, 1464.0 micro g/l of 2-amino-4,6-dinitrotoluene, 6693.0 of micro g/l 4-amino-2,6-dinitrotoluene, 2.1 micro g/l of 2,4-DNT, …

AdultMaleFirearmsHazardous WasteMetaboliteHealth StatusEarly detectionUrinechemistry.chemical_compoundBurning eyesNitroaromatic explosivesGermanyOccupational ExposureTrinitrotolueneHumansMilitary MedicinePublic Health Environmental and Occupational HealthMiddle Agedmusculoskeletal systemSoil contaminationOccupational DiseasesDinitrobenzenesCross-Sectional StudieschemistryEnvironmental chemistryFemaleOriginal ArticleWaste disposalEnvironmental MonitoringTrinitrotolueneOccupational and environmental medicine
researchProduct

Automatic algorithm for monitoring systolic pressure variation and difference in pulse pressure.

2009

BACKGROUND: Difference in pulse pressure (dPP) reliably predicts fluid responsiveness in patients. We have developed a respiratory variation (RV) monitoring device (RV monitor), which continuously records both airway pressure and arterial blood pressure (ABP). We compared the RV monitor measurements with manual dPP measurements. METHODS: ABP and airway pressure (PAW) from 24 patients were recorded. Data were fed to the RV monitor to calculate dPP and systolic pressure variation in two different ways: (a) considering both ABP and PAW (RV algorithm) and (b) ABP only (RV(slim) algorithm). Additionally, ABP and PAW were recorded intraoperatively in 10-min intervals for later calculation of dPP …

AdultMaleFluid responsivenessBlood PressureAutomationMonitoring IntraoperativeAbdomenMedicineHumansIn patientPulseAgedObserver VariationBlood Volumebusiness.industryAirway ResistanceLimits of agreementReproducibility of ResultsMiddle AgedReference StandardsPulse pressureAnesthesiology and Pain MedicineBlood pressureData Interpretation StatisticalRespiratory MechanicsFemalebusinessAlgorithmAlgorithmsAnesthesia and analgesia
researchProduct

Urinary levels of enniatin B and its phase I metabolites: First human pilot biomonitoring study

2018

Abstract Enniatins (Enns) are mycotoxins produced by Fusarium spp. and are widely distributed contaminants of cereals and derivate products. Among the different identified enniatins, Enn B is the most relevant analogue in cereals in Europe. Therefore, the aim of this study was to investigate for the first time the occurrence of Enn B and Enn B phase I metabolites in 300 human urine samples throughout an ultrahigh-performance liquid chromatography-high resolution mass spectrometry (UHPLC-Q-Orbitrap HRMS) methodology. Three different sample preparation procedures were evaluated and salting-out liquid-liquid extraction showed satisfactory validation results. Enn B was quantified in 83.7% of sa…

AdultMaleFusariumEnniatin B Metabolites Urine Human Biomonitoring OrbitrapPilot ProjectsUrineToxicologyOrbitrap01 natural sciencesMass Spectrometrylaw.inventionchemistry.chemical_compound0404 agricultural biotechnologyUrinary levelslawDepsipeptidesBiomonitoringHumansSample preparationMycotoxinChromatography High Pressure LiquidEnniatin BChromatographybiology010401 analytical chemistryReproducibility of Results04 agricultural and veterinary sciencesGeneral MedicineMiddle Agedbiology.organism_classification040401 food science0104 chemical sciencesItalychemistryMicrosomes LiverFemaleEnvironmental MonitoringFood Science
researchProduct

Subchronic Antidepressant Treatment with Venlafaxine or Imipramine and Effects on Blood Pressure and Heart Rate: Assessment by Automatic 24-Hour Moni…

1996

Venlafaxine is a new nontricyclic antidepressant inhibiting the reuptake of serotonin, noradrenaline, and, to a lesser extent, dopamine without antagonizing cholinergic, histaminergic, or noradrenergic receptors. Significantly, in a first placebo-controlled safety and efficacy study, high doses of venlafaxine increased blood pressure in some study subjects. In order to investigate further the effect of subchronic antidepressant drug treatment on blood pressure and heart rate, the effects of a conventional tricyclic (imipramine) and a structurally different phenethylamine antidepressant (venlafaxine) were compared. Sixteen inpatients with major depression (melancholic type) were treated for …

AdultMaleImipramineVenlafaxine HydrochlorideHemodynamicsBlood PressureVenlafaxineAntidepressive Agents TricyclicImipramineDouble-Blind MethodHeart RateHeart ratemedicineHumansPharmacology (medical)Psychiatric Status Rating ScalesDepressive Disorderbusiness.industryVenlafaxine HydrochlorideGeneral MedicineBlood Pressure Monitoring AmbulatoryMiddle AgedCyclohexanolsPsychiatry and Mental healthBlood pressureAnesthesiaCirculatory systemAntidepressive Agents Second-GenerationAntidepressantFemalebusinessmedicine.drugPharmacopsychiatry
researchProduct

Assessment of Pulmonary Mechanics and Gastric Inflation Pressure During Mask Ventilation

1995

AbstractIntroduction:Mask ventilation is a procedure routinely used in emergency medicine. Potential hazards are inadequate alveolar ventilation and inflation of the stomach with air, leading to subsequent regurgitation and aspiration. The aim of this study was to measure lung function and gastric inflation pressures during mask ventilation.Methods:For this purpose, 31 patients scheduled for routine urological procedures were studied during induction of anesthesia. Lung function was assessed by recording respiratory flow and pressure directly at the face mask. Gastric inflation was observed with a microphone taped to the epigastric area.Results:Gastric inflation occurred in 22 of the 31 pat…

AdultMaleInflationManometrymedia_common.quotation_subjectmedicine.medical_treatmentRegurgitation (circulation)Respiratory physiologyEmergency NursingLaryngeal MasksPressuremedicineHumansCardiopulmonary resuscitationRespiratory systemMonitoring Physiologicmedia_commonbusiness.industryStomachStomachInsufflationMiddle AgedRespiration ArtificialCompliance (physiology)medicine.anatomical_structureAnesthesiaRespiratory MechanicsEmergency MedicineFemalebusinessAirwayPrehospital and Disaster Medicine
researchProduct

Biomonitoring in wearers of permethrin impregnated battle dress uniforms in Afghanistan and Germany.

2013

Objectives To analyse differences in uptake of the insecticide permethrin in wearers of non-impregnated and permethrin impregnated battle dress uniforms (BDU) in Afghanistan and Germany. Methods In two separate studies, in April 2003–January 2004 (study I, n=549) and in February–April 2005 (study II, n=195), healthy female and male members of the German Federal Armed Forces were equipped with permethrin impregnated BDU (two sub-cohorts in Germany and one in Afghanistan) while members equipped with non-impregnated uniforms served as a control group. Human biomonitoring was conducted before, during and after wearing the uniforms by measuring permethrin metabolites in urine samples via GC–MS. …

AdultMaleInsecticidesAdolescentSkin AbsorptionPopulationStatistics NonparametricToxicologyCohort StudiesYoung AdultAfghanProtective ClothingEnvironmental protectionGermanyOccupational Exposureparasitic diseasesBiomonitoringMedicineHumanseducationPermethrineducation.field_of_studybusiness.industrySmokingPublic Health Environmental and Occupational HealthAfghanistanMiddle AgedMilitary PersonnelCase-Control StudiesFemalebusinessPermethrinmedicine.drugOccupational and environmental medicine
researchProduct

External and internal exposure of wine growers spraying methyl parathion.

2005

Organophosphates, used in agriculture, are readily absorbed through the skin. We investigated the relationship between dermal and inhalative methyl parathion exposure and the plasma levels. Twenty-three healthy wine growers sprayed the insecticide for 50 min. Fluorescent brilliant sulfoflavin was added to the spraying fluids and filter papers were fixed on the subjects. The filter papers were used to evaluate the amount of brilliant sulfoflavine on the unprotected skin fluorometrically. Inhalative exposure was measured with personal air sampler. Plasma concentrations of methyl parathion and its metabolite methyl paraoxon were determined with gas chromatography. Cholinesterase activity in se…

AdultMaleInsecticidesErythrocytesMetaboliteSkin AbsorptionWineMethyl ParathionToxicologyDermal exposureToxicologychemistry.chemical_compoundOccupational ExposuremedicineParathion methylCholinesterasesHumansCholinesteraseInhalation ExposureChromatographyParaoxonbiologyGeneral MedicinePesticideParathionchemistrybiology.proteinGas chromatographyCholinesterase Inhibitorsmedicine.drugEnvironmental MonitoringToxicology letters
researchProduct

Noninvasive measurement of intracranial pressure: Is it possible?

2007

BACKGROUND: Some publications suggest a strong correlation between the intracranial pressure and the intraocular pressure. Other studies claim no correlation between these two physiologic variables. Our aim was to study whether the tonometry could be a useful method to evaluate intracranial pressure in patients with suspected intracranial abnormality. METHODS: We evaluated the correlation between the intracranial pressure and the intraocular pressure, the intracranial pressure and the mean arterial pressure, and the intraocular pressure and the mean arterial pressure in 22 patients, initially comatose, who were admitted to our hospital. All patients required the intracranial pressure monito…

AdultMaleIntraocular pressureMean arterial pressureIntracranial PressureCorrelation coefficientCritical Care and Intensive Care MedicineStatistics Nonparametriclaw.inventionTonometry OcularlawHumansMedicineMonitoring PhysiologicIntracranial pressureComabusiness.industryIntensive Care UnitsPressure measurementBlood pressureBrain InjuriesAnesthesiaLinear ModelsIntracranial pressure monitoringFemaleSurgerymedicine.symptombusinessJournal of Trauma-Injury Infection and Critical Care
researchProduct

Tolerability of 24-hour intraocular pressure monitoring of a pressure-sensitive contact lens.

2013

Purpose To investigate tolerability and safety of a new diagnostic device for 24-hour intraocular pressure monitoring in healthy subjects and age-matched glaucoma patients. Patients and methods Twenty healthy subjects (group 1) and 20 age-matched glaucoma patients (group 2) were included in this prospective, single-center, open, observational parallel group study. The SENSIMED Triggerfish Sensor is a soft disposable contact lens embedding a telemetry chip and strain gauge sensor for continuous intraocular pressure monitoring. The Sensor was placed in 1 eye for 24 hours. Tolerability was evaluated using a visual analog scale (range, 0 to 100; 0=no discomfort; 100=very severe discomfort). Saf…

AdultMaleIntraocular pressuremedicine.medical_specialtygenetic structuresCorneal PachymetryVisual analogue scaleVisual AcuityGlaucomaMonitoring AmbulatoryTonometry OcularOphthalmologyMedicineHumansTelemetryProspective StudiesCorneal pachymetryProspective cohort studyIntraocular PressureAgedmedicine.diagnostic_testEquipment Safetybusiness.industryCorneal TopographyGlaucomaMiddle Agedmedicine.diseaseCorneal topographyContact Lenses Hydrophiliceye diseasesCircadian RhythmContact lensOphthalmologyTolerabilityPatient SatisfactionFemalebusinessJournal of glaucoma
researchProduct

Measurement of EMG activity with textile electrodes embedded into clothing.

2007

Novel textile electrodes that can be embedded into sports clothing to measure averaged rectified electromyography (EMG) have been developed for easy use in field tests and in clinical settings. The purpose of this study was to evaluate the validity, reliability and feasibility of this new product to measure averaged rectified EMG. The validity was tested by comparing the signals from bipolar textile electrodes (42 cm(2)) and traditional bipolar surface electrodes (1.32 cm(2)) during bilateral isometric knee extension exercise with two electrode locations (A: both electrodes located in the same place, B: traditional electrodes placed on the individual muscles according to SENIAM, n=10 person…

AdultMaleMaterials scienceKnee JointPhysiologyAverage rectified valueCoefficient of variationTransducersBiomedical EngineeringBiophysicsMonitoring AmbulatoryIsometric exerciseElectromyographySports MedicineSignalSensitivity and SpecificityClothingPhysiology (medical)Isometric ContractionmedicineHumansTreadmillElectrodesExerciseSimulationAnalysis of Variancemedicine.diagnostic_testElectromyographyTextilesReproducibility of ResultsRepeatabilityEquipment DesignMiddle AgedEquipment Failure AnalysisTorqueElectrodeFemaleBiomedical engineeringPhysiological measurement
researchProduct