Reducing Patient Radiation Dose With Image Noise Reduction Technology in Transcatheter Aortic Valve Procedures
2015
X-ray radiation exposure is of great concern for patients undergoing structural heart interventions. In addition, a larger group of medical staff is required and exposed to radiation compared with percutaneous coronary interventions. This study aimed at quantifying radiation dose reduction with implementation of specific image noise reduction technology (NRT) in transcatheter aortic valve implantation (TAVI) procedures. We retrospectively analyzed 104 consecutive patients with TAVI procedures, 52 patients before and 52 after optimization of x-ray radiation chain, and implementation of NRT. Patients with 1-step TAVI and complex coronary intervention, or complex TAVI procedures, were excluded…
Usefulness of multislice computed tomography to assess patency of coronary artery stents versus conventional coronary angiography
2008
BACKGROUND: The aim of the present study was to assess the in-stent restenosis and occlusion of coronary artery stents by multislice computed tomography (MSCT) compared with conventional coronary angiography in patients with atypical chest pain and not practicable/non-conclusive stress test. METHODS: Between December 2004 and March 2006, 81 patients were scheduled and of these 72 (65 men, mean age 61 years) with 90 stents underwent MSCT angiography using a 16-slice scanner, Toshiba Aquilion 16, 8-12 months after stent placement. RESULTS: Of the 90 stents, 71 (79%) could be assessed and 19 (21%) were excluded because the image quality at the stent level was incompatible with diagnostic asses…
MDCT and virtual angioscopy in spontaneous aortocaval fistula
2007
Aortocaval fistula is a rare, less than 1%, but life threatening complication, of abdominal aortic aneurysm. Mortality is high but prompt recognition of the fistula can reduce mortality rate. The multidetector row CT (MDCT) findings in a 69-year-old patient with a complex medical history characterized by previous episodes of myocardial ischemia, is reported. MDCT shows an early homogeneous enhancement of the inferior vena cava, slightly dilated at the liver level and markedly narrowed above the renal vein due to aneurysm compression. The patient underwent to emergency laparotomy but died during surgery for cardiac arrest. MDCT allows a prompt recognition of the fistula and different compute…
64-MDCT ECG gating in the evaluation of pre and post-operative ascending aorta: what is essential to know and necessary to report?
2007
64-detector Computed Tomography in Reoperative Assessment of Vascular Anatomy of Middle Colic Artery in Left-sided Colon Cancer
2007
Evaluation of Cardiac Volumetric and Functional Parameters
2008
Heart Rate Sequential Analysis During Multidetector Computed Tomography Coronary Angiography: What Factors Do You Take Into Account In Understanding …
2007
Role of Densitometric Criteria in Evaluation of Effectiveness of Antiangiogenic Therapies in Metastatic Colorectal Cancer: An Italian Clinical Experi…
2017
Background/Aim: To evaluate the role of densitometric criterion using the Choi Criteria in the assessment of the response to antiangiogenic treatments of metastatic colorectal cancer (mCRC) compared to the RECIST criteria. Patients and Methods: Fifty-four patients (mean age=50.6 years ) affected by advanced colorectal cancer and with hepatic and possibly peritoneal and pulmonary metastases, that can be treated with bevacizumab, were prospectively evaluated by computerized tomography (CT) scan. Metastases were also evaluated by CT in onedimensional form according to RECIST. Results: Results show that in 58% of analyzed cases, stable disease according to RECIST coincided with stable disease a…
An edge-driven 3D region-growing approach for upper airway morphology and volume evaluation in patients with Pierre Robin sequence
2015
Abstract: Pierre Robin sequence (PRS) is a pathological condition responsible for a sequence of clinical events, such as breathing and feeding difficulties, that must be addressed to give the patient at least a chance to survive. By using medical imaging techniques, in a non-intrusive way, the surgeon has the opportunity to obtain 3D views, reconstruction of the regions of interest (ROIs), useful to increase understanding of the PRS patient’s condition. In this paper, a semi-automatic approach for segmentation of the upper airways is proposed. The implemented approach uses an edge-driven 3D region-growing algorithm to segment ROIs and 3D volume-rendering technique to reconstruct the 3D mode…
Airway distensibility by HRCT in asthmatics and COPD with comparable airway obstruction.
2013
Introduction: Decreased airway distensibility (AD) in response to deep inspirations, as assessed by HRCT, has been associated with the severity of asthma and COPD. Aims: The current study was designed to compare the magnitude of AD by HRCT in individuals with asthma and COPD with comparable degrees of bronchial obstruction, and to explore factors that may influence it. Results: We enrolled a total of 12 asthmatics (M/F:7/5) and 8 COPD (7/1) with comparable degree of bronchial obstruction (FEV1% predicted mean±SEM: 69.1 ± 5.2% and 61.2 ± 5.0%, respectively; p = 0.31). Each subject underwent chest HRCT at FRC and at TLC. A total of 701 airways (range 20 to 38 airway per subject; 2.0 to 23.1 m…