Search results for "multidetector"
showing 10 items of 50 documents
Therapy response evaluation of malignant lymphoma in a multicenter study: comparison of manual and semiautomatic measurements in CT.
2014
Purpose: Comparison of manual one-/bi-dimensional measurements versus semi-automatically derived one-/bi-dimensional and volumetric measurements for therapy response evaluation of malignant lymphoma during CT follow-up examinations in a multicenter setting. Materials and Methods: MSCT data sets of patients with malignant lymphoma were evaluated before (baseline) and after two cycles of chemotherapy (follow-up) at radiological centers of five university hospitals. The long axis diameter (LAD), the short axis diameter (SAD) and the bi-dimensional WHO of 307 target lymph nodes were measured manually and semi-automatically using dedicated software. Lymph node volumetry was performed semi-automa…
Quantitative structural analysis of trabecular alveolar bone in the mandible by multidetector computed tomography: Differences according to tooth pre…
2019
Background and objective: There is a lack of quantitative measures of the quality of alveolar trabecular bone, an important factor in implantology. This study aimed to develop a method of objectively assessing the quality of trabecular bone by means of image processing and structural analysis of multidetector computed tomography images and to establish differences between tooth types and tooth presence/absence. Materials and methods: We analyzed 20 patients who underwent multidetector computed tomography to evaluate mandibular bone and tooth positioning. Image analysis included automatic segmentation of the mandible, obtainment of sections perpendicular to the dental arch, and structural an…
Multidetector Computed Tomography Angiography (MD-CTA) of Coronary Artery Bypass Grafts – Update 2017
2017
Coronary artery bypass grafting (CABG) is still an important therapeutic approach in the treatment especially of advanced coronary artery disease. In this study, we elucidate the current role of multidetector computed tomography angiography (MD-CTA) in imaging patients after CABG surgery.This study is based on recent reports in the literature (2007 - 2016) on imaging of CABG using 64-slice MD-CT scanners and beyond. We included 13 reports that compared ECG-gated MD-CTA with conventional invasive coronary angiography (ICA) as the reference standard for the assessment of graft patency and for the detection of 50 % stenoses. These studies had to provide absolute values for true-positive, true-…
A rare case of a coronary artery anomaly detected on multidetector computed tomography
2013
An anomalous aortic origin of the coronary artery arising from the opposite sinus with an interarterial course is a rare condition that is associated with a high risk of sudden cardiac death during or after strenuous exertion. We herein report the case of a 47-year-old woman presenting with chest pain, syncope and palpitations who presented with a rare coronary artery anomaly on multidetector computed tomography coronary artery (MDCT-CA) with prospective electrocardiogram (ECG) gating.
High Resolution CT Angiography in Detection of an Aneurysm of the Vein of Galen as a Source of Intracranial Haemorrhage in a Newborn.
2011
Cerebral haemorrhage is a rare condition in infants and carries a known poor prognosis. Common causes of spontaneous haemorrhage include various vascular venous lesions due to incomplete hydrovenous maturation, among them Galen vein aneurysm may be a very rare cause of cerebral haemorrhage. This report emphasizes the role of multidector CT with high resolution CT angiography in a newborn with cerebral hemorrhage caused by Galen vein aneurysm rupture. MDCT with high resolution CT angiography helps to differentiate the cause of haemorrhage, and to address the appropriate treatment.
Hepatic mesenchymal hamartoma in a preterm newborn: demonstration by low-dose multidetector CT.
2007
Primary liver tumours are very rare in the neonatal period. Differential diagnoses include haemangioendothelioma, malignant hepatoblastoma and mesenchymal hamartoma. Due to non-specific clinical symptoms and indecisive imaging findings, correct diagnosis may be difficult to establish. We report a female preterm newborn who was delivered at 33 weeks of gestation and in whom ultrasonography (US) revealed a large cystic intraabdominal tumour of unknown origin. For further evaluation, contrast-enhanced multidetector computed tomography (CT) was performed on the 4th day of life using a low-dose protocol (80 kVp, 50 mAs, collimation 0.75 mm, total effective dose 3.6 mSv). Based on CT findings, di…
Common pitfalls when using the Liver Imaging Reporting and Data System (LI-RADS): lessons learned from a multi-year experience
2018
The goal of the Liver Imaging Reporting and Data System (LI-RADS) is to standardize the interpretation and reporting of liver observations on contrast-enhanced CT and MR imaging of patients at risk for hepatocellular carcinoma. Although LI-RADS represents a significant achievement in standardization of the diagnosis and management of cirrhotic patients, complexity and caveats to the algorithm may challenge correct application in clinical practice. The purpose of this paper is to discuss common pitfalls and potential solutions when applying LI-RADS in practice. Knowledge of the most common pitfalls may improve the diagnostic confidence and performance when using the LI-RADS system for the in…
Imaging of inner ear malformations: a primer for radiologists
2021
AbstractIn the multidisciplinary management of patients with inner ear malformations (IEMs), the correct diagnosis makes the differences in terms of clinical and surgical treatment. The complex anatomical landscape of the inner ear, comprising several small structures, makes imaging of this region particularly challenging for general radiologists. Imaging techniques are important for identifying the presence and defining the type of IEM and the cochlear nerve condition. High-resolution magnetic resonance imaging (MRI) sequences and high-resolution computed tomography (HRCT) are the mainstay imaging techniques in this area. Dedicated MRI and HRCT protocols play an important role in the diagn…
Tomografía computarizada multidetector en el traumatismo facial: informe estructurado y observaciones clave para un abordaje sistemático
2019
Facial fractures, often related to traffic accidents, assault, work-related accidents, or falls, account for a considerable number of emergencies in our hospitals and are associated with high morbidity and mortality. Multidetector computed tomography (MDCT) is the imaging technique of choice in this scenario because it is widely available, fast, and useful for characterizing facial fractures and associated complications, including those located in the head. For all these reasons, MDCT is fundamental in the clinical management of these patients and in planning surgery. This paper describes the radiological anatomy of the facial region, underlining the importance of the facial buttresses, and…