Search results for "myopia"
showing 10 items of 165 documents
Changes in the visual field following laser in situ keratomileusis for myopia
2007
Purpose: To assess the changes of the visual field (VF) caused by transient intraocular pressure (IOP) peaks during laser in situ keratomileusis (LASIK) surgery for myopia using automated perimetry. Methods: This prospective study involved 94 eyes of 94 patients who underwent a conventional LASIK procedure. A complete eye examination was carried out in which the IOP measurement, and Humphrey 24-2 SITA standard VF were tested prior to LASIK and 6 and 12 months after LASIK. Patients were divided into two subgroups according to their refractive error. VF global indices, Glaucoma Hemifield Test and the number of depressed points deviating at p < 5%, p < 2%, p < 1% and p < 0.5% on the Pattern …
Refractive lens exchange with an array multifocal intraocular lens.
2002
ABSTRACT PURPOSE: To prospectively evaluate safety, efficacy, predictability, stability, complications, and patient satisfaction after refractive lens exchange (clear lens extraction) followed by posterior chamber implantation of a multifocal intraocular lens (IOL). METHODS: Fifty eyes of 25 patients (mean age 51 years, range 44 to 62 years) with preoperative spherical equivalent refraction between -15.50 and +5.75 D and cylinder between 0 and 1.50 D underwent bilateral implantation of a zonal progressive multifocal IOL (Array, AMO). RESULTS: Eyes were divided into group A (n=24; myopia, average preoperative spherical equivalent refraction -7.11 ± 3.25 D (-1.75 to -15.50 D), and group B (n=…
Assessment of corneal thickness and tear meniscus during contact-lens wear
2014
To assess the effect of seven different daily disposable contact lenses upon corneal thickness, as well as upon tear meniscus volume, by using optical coherence tomography (OCT).Thirty-four young healthy subjects wore seven different types of daily disposable soft contact lenses, each for a period of 12h: Delefilcon A, Nelfilcon A, Omafilcon A, Filcon II3, Narafilcon A, Etafilcon A and Hilafilcon B. Central and mid-peripheral corneal thickness and lower tear meniscus volume (TMV) were measured using an OCT device during contact-lens wear at 4-h intervals throughout a 12-h period. Measurements were also recorded without any contact lenses being worn during a day.In the no-lens scenario a sma…
Retinal Imaging through Phakic Iris-Claw IOL.
2014
AbstractBackground: Phakic anterior chamber iris-fixated IOL (PIOL) are established for the correction of high myopia. These patients require attention to macular pathologies. This study was to evaluate the quality of imaging through the PIOLs. Methods: 54 eyes of 31 myopic and hyperopic patients with Verisyse®, Verisyse toric®, and Veriflex® phakic iris-fixated IOL were included. Mean preoperative refraction was −11.0 D and +5.7 D, respectively; mean follow-up time was 7.4 years (5–11 years). A matched control group was formed without PIOL implantation. OCT scans were performed and evaluated qualitatively and quantitatively. Results: In 52 eyes of 31 patients (96%), a 3D-OCT image and fund…
The relationship of ocular geometry with refractive error in normal and low birth weight adults
2020
Purpose Low birth weight (BW) individuals have an increased risk for myopic refractive error. However, it is unclear which ocular geometric alterations lead to an increase in myopic refractive error. This study aims to evaluate the impact of ocular biometry in interaction with BW on refractive error. Methods Participants of the prospective, observational, population-based Gutenberg Health Study (GHS) with self-reported BW aged 40–80 years and objective refraction and optical biometry were included. Linear regression analyses were conducted to evaluate associations between spherical equivalent with corneal power, anterior chamber depth, lens thickness and axial length and its interaction wit…
Photodynamic therapy with verteporfin for juxtafoveal choroidal neovascularization in pathologic myopia: a long-term follow-up study.
2007
Purpose To assess the effect of verteporfin photodynamic therapy (PDT) in juxtafoveal choroidal neovascularization (CNV) secondary to pathologic myopia (PM). Design Prospective, open-label, consecutive, interventional case series. Methods We prospectively followed a series of 48 consecutive patients (49 eyes) with pathologic myopia (≥ 6 diopters) who received verteporfin PDT for juxtafoveal CNV. This population was divided into two groups based on age (group A ≤ 55 years old, group B >55 years old), in three subgroups based on CNV lesion size, and in three categories based on refractive error at baseline. Results The median follow-up was 32 months (range, 12 to 56 months). Visual acuity (VA…
Clinical outcomes after implantation of a posterior chamber collagen copolymer phakic intraocular lens with a central hole for myopic correction.
2013
Purpose To evaluate the efficacy, predictability, safety, and stability of a new-model posterior chamber Implantable Collamer Lens phakic intraocular lens (pIOL) (V4c Visian) to correct myopia. Setting Private practice, Oviedo, Spain. Design Case series. Methods This study enrolled patients who had implantation of a new pIOL design with a central hole for more natural aqueous flow, eliminating the need for neodymium:YAG iridotomy or peripheral iridectomy. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refractive error, intraocular pressure (IOP), endothelial cell count, central vault, and adverse events were evaluated 6 months postoperatively. Results The study enroll…
Association of low birth weight with myopic refractive error and lower visual acuity in adulthood: results from the population-based Gutenberg Health…
2017
PurposeLow birth weight (BW) is linked to impaired organ development in childhood, including altered ocular morphological and functional development. The aim of this study was to evaluate whether low BW has long-term effects on visual acuity and refraction in adulthood.MethodsThe Gutenberg Health Study is a population-based, observational cohort study in Germany, including 15 010 participants aged between 35 and 74 years. These participants were divided into three different BW groups (low: <2500 g; normal: between 2500 and 4000 g; and high: >4000 g). Best-corrected visual acuity and objective refraction were examined. We used multivariable linear regression models with adjustment for …
Prevalence of myopic maculopathy in the German population: results from the Gutenberg health study.
2019
AimsTo determine the prevalence of myopic maculopathy in the general population in Germany and to analyse potential associations with ocular and systemic factors.DesignThe Gutenberg Health Study is a population-based study, including 15 010 participants aged 35–74 years.MethodsMyopic maculopathy was graded in phakic eyes with spherical equivalent ≤−6 D by assessing fundus photographs according to a recent international photographic classification system (META-PM). 801 eyes of 519 participants (mean age 51.0±0.77 years) met the conditions and had gradable fundus photographs. Age-specific prevalence estimates were computed. Multivariable logistic regression analysis was used to assess associa…
Choice of spatial frequency for contrast sensitivity evaluation after corneal refractive surgery.
2002
ABSTRACT PURPOSE: To study the utility of measurements of contrast sensitivity at different spatial frequencies as an index of visual recovery following refractive surgery. METHODS: Contrast sensitivity at 1.5, 3, 6, 12, and 18 c/deg was measured with the Stereo Optical FACT chart in 20 patients after photorefractive keratectomy (PRK) using the Nidek EC-5000 excimer laser system, and in 18 patients following laser in situ keratomileusis (LASER). Contrast sensitivity was measured preoperatively and 1, 3, 6, and 12 months after surgery. RESULTS: Results showed a statistically significant reduction (P<01) in contrast sensitivity at all spatial frequencies in PRR patients during the first an…